Installation manual
Daikin room air conditioner English
Installation manual
Daikin room air conditioner
CTXM15R2V1B
CTXM15R5V1B
FTXM20R2V1B
FTXM20R5V1B
FTXM25R2V1B
FTXM25R5V1B
FTXM35R2V1B
FTXM35R5V1B
FTXM42R2V1B
FTXM42R5V1B
FTXM50R2V1B
FTXM60R2V1B
FTXM71R2V1B
ATXM20R2V1B
ATXM20R5V1B
ATXM25R2V1B
ATXM25R5V1B
ATXM35R2V1B
ATXM35R5V1B
ATXM50R2V1B
Table of contents
Installation manual
2
CTXM15+FTXM20~42+ATXM20~35R2/5V1B +
FTXM50~71R2V1B + ATXM50R2V1B
Daikin room air conditioner
3P482320-11R – 2020.06
Table of contents
1 About the documentation 2
1.1 About this document.................................................................. 2
2 Specific installer safety instructions 2
3 About the box 3
3.1 Indoor unit ................................................................................. 3
3.1.1 To remove the accessories from the indoor unit......... 3
4 About the unit 3
4.1 About the wireless LAN ............................................................. 4
4.1.1 Precautions when using the wireless LAN.................. 4
4.1.2 Basic parameters ........................................................ 4
5 Unit installation 4
5.1 Preparing the installation site .................................................... 4
5.1.1 Installation site requirements of the indoor unit .......... 4
5.2 Opening the indoor unit ............................................................. 4
5.2.1 To remove the front panel........................................... 4
5.2.2 To open the service cover........................................... 4
5.2.3 To remove the front grille ............................................ 4
5.3 Mounting the indoor unit............................................................ 5
5.3.1 To install the mounting plate....................................... 5
5.3.2 To drill a wall hole ....................................................... 6
5.3.3 To remove the pipe port cover.................................... 6
5.4 Connecting the drain piping....................................................... 6
5.4.1 To connect the piping on right side, right-back, or
right-bottom ................................................................. 6
5.4.2 To connect the piping on left side, left-back, or left-
bottom ......................................................................... 7
5.4.3 To check for water leaks............................................. 7
6 Piping installation 7
6.1 Preparing refrigerant piping....................................................... 7
6.1.1 Refrigerant piping requirements.................................. 7
6.1.2 Refrigerant piping insulation ....................................... 7
6.2 Connecting the refrigerant piping .............................................. 8
6.2.1 To connect the refrigerant piping to the indoor unit .... 8
7 Electrical installation 8
7.1 Specifications of standard wiring components .......................... 8
7.2 To connect the electrical wiring to the indoor unit ..................... 8
8 Finishing the indoor unit installation 9
8.1 To insulate the drain piping, refrigerant piping and
interconnection cable ................................................................ 9
8.2 To pass the pipes through the wall hole.................................... 9
8.3 To fix the unit on the mounting plate ......................................... 9
8.4 To close the indoor unit ............................................................. 9
8.4.1 To re-install the front grille .......................................... 9
8.4.2 To close the service cover .......................................... 10
8.4.3 To re-install the front panel ......................................... 10
9 Commissioning 10
9.1 Checklist before commissioning................................................ 10
9.2 To perform a test run ................................................................. 10
9.2.1 To perform a test run using the user interface............ 10
10 Technical data 10
10.1 Wiring diagram .......................................................................... 10
10.1.1 Unified wiring diagram legend..................................... 10
1 About the documentation
1.1 About this document
INFORMATION
Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.
Target audience
Authorised installers
INFORMATION
This appliance is intended to be used by expert or trained
users in shops, in light industry, and on farms, or for
commercial and household use by lay persons.
Documentation set
This document is part of a documentation set. The complete set
consists of:
â–ªGeneral safety precautions:
â–ª Safety instructions that you MUST read before installing
â–ª Format: Paper (in the box of the indoor unit)
â–ªIndoor unit installation manual:
â–ª Installation instructions
â–ª Format: Paper (in the box of the indoor unit)
â–ªInstaller reference guide:
▪ Preparation of the installation, good practices, reference data,…
â–ª Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
Technical engineering data
â–ª A of the latest technical data is available on the regionalsubset
Daikin website (publicly accessible).
â–ª The of latest technical data is available on the Daikinfull set
Business Portal (authentication required).
2 Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Unit installation (see ["5Unit installation"44])
WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
WARNING
Do NOT place objects below the indoor and/or outdoor unit
that may get wet. Otherwise condensation on the main unit
or refrigerant pipes, air filter dirt or drain blockage may
cause dripping, and objects under the unit may get dirty or
damaged.
3 About the box
Installation manual
3
CTXM15+FTXM20~42+ATXM20~35R2/5V1B +
FTXM50~71R2V1B + ATXM50R2V1B
Daikin room air conditioner
3P482320-11R – 2020.06
CAUTION
For walls containing a metal frame or a metal board, use a
wall embedded pipe and wall cover in the feed-through
hole to prevent possible heat, electrical shock, or fire.
Piping installation (see ["6Piping installation"47])
DANGER: RISK OF BURNING/SCALDING
CAUTION
â–ª Use the flare nut fixed to the unit.
â–ª To prevent gas leakage, apply refrigeration oil only to
the inside of the flare. Use refrigeration oil for R32.
â–ª Do NOT reuse joints.
CAUTION
â–ª Do NOT use mineral oil on flared part.
â–ª NEVER install a drier to this R32 unit to guarantee its
lifetime. The drying material may dissolve and damage
the system.
CAUTION
â–ª Incomplete flaring may cause refrigerant gas leakage.
â–ª Do NOT re-use flares. Use new flares to prevent
refrigerant gas leakage.
â–ª Use flare nuts that are included with the unit. Using
different flare nuts may cause refrigerant gas leakage.
Electrical installation (see ["7Electrical installation"48])
DANGER: RISK OF ELECTROCUTION
WARNING
â–ª All wiring MUST be performed by an authorised
electrician and MUST comply with the applicable
legislation.
â–ª Make electrical connections to the fixed wiring.
â–ª All components procured on-site and all electrical
construction MUST comply with the applicable
legislation.
WARNING
â–ª If the power supply has a missing or wrong N-phase,
equipment might break down.
â–ª Establish proper earthing. Do NOT earth the unit to a
utility pipe, surge absorber, or telephone earth.
Incomplete earthing may cause electrical shock.
â–ª Install the required fuses or circuit breakers.
â–ª Secure the electrical wiring with cable ties so that the
cables do NOT come in contact with sharp edges or
piping, particularly on the high-pressure side.
â–ª Do NOT use taped wires, stranded conductor wires,
extension cords, or connections from a star system.
They can cause overheating, electrical shock or fire.
â–ª Do NOT install a phase advancing capacitor, because
this unit is equipped with an inverter. A phase
advancing capacitor will reduce performance and may
cause accidents.
WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
Use an all-pole disconnection type breaker with at least
3 mm between the contact point gaps that provide full
disconnection under overvoltage category III.
WARNING
If the supply cord is damaged, it MUST be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
WARNING
Do NOT connect the power supply to the indoor unit. This
could result in electrical shock or fire.
WARNING
â–ª Do NOT use locally purchased electrical parts inside
the product.
â–ª Do NOT branch the power supply for the drain pump,
etc. from the terminal block. This could result in
electrical shock or fire.
WARNING
Keep the interconnection wiring away from copper pipes
without thermal insulation as such pipes will be very hot.
3 About the box
3.1 Indoor unit
3.1.1 To remove the accessories from the
indoor unit
1Remove:
â–ª the accessory bag located at the bottom of the package,
â–ª the mounting plate attached to the back of the indoor unit,
â–ª the spare SSID sticker located on the front grille.
1×1× 2× 2× 2×1× 1× 1×1× 1× 1×
fe1d e2ba c g h i j
aInstallation manual
bOperation manual
cGeneral safety precautions
dSpare SSID sticker
e1 Class 15~42: Silver allergen removal air purifying filter
(without frame)
e2 Class 50~71: Titanium apatite deodorising filter and
silver allergen removal air purifying filter (with frame)
fIndoor unit fixing screw (M4×12L). Refer to "8.3To fix the
unit on the mounting plate"[49].
gDry battery AAA.LR03 (alkaline) for user interface
hUser interface holder
iUser interface
jMounting plate
â–ª Do NOT throw away the spare sticker. KeepSpare SSID sticker.
it in a safe place in case it is needed in future (e.g. in case the
front grille was replaced attach it to the new front grille).
4 About the unit
WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.


Product specificaties