Daikin FMA60RVMA Handleiding

Daikin Airco FMA60RVMA

Lees hieronder de 📖 handleiding in het Nederlandse voor Daikin FMA60RVMA (32 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 58 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
mfort.
nd comf
E
Enjoy year-roun
DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL
MODELS
FMA50RVMA
FMA60RVMA
FMA71RVMA
Read the precautions in this manual carefully
before operating the unit. This appliance is lled with R32.
• Keepthismanualwheretheusercaneasilyndit.
• TheprecautionsdescribedhereinareclassiedasWARNINGandCAUTION.Theybothcontainimportantinformationregarding
safety.Besuretoobserveallprecautionswithoutfail.
WARNING CAUTION
Failuretofollowtheseinstructionsproperlymayresultin
personalinjuryorlossoflife.
Failuretofollowtheseinstructionsproperlymayresultin
propertydamageorpersonalinjury,whichmaybeserious
dependingonthecircumstances.
Neverattempt. Besuretofollowthe
instructions.
Besuretoestablishan
earthconnection.
• Afterreading,keepthismanualinaconvenientplacesothatyoucanrefertoitwhenevernecessary.Iftheequipmentis
transferredtoanewuser,besurealsotohandoverthemanual.
WARNING
• Donotusemeanstoacceleratethedefrostingprocessortoclean,otherthanthoserecommendedbythe
manufacturer.
• Theappliancemustbestoredinaroomwithoutcontinuouslyoperatingignitionsources(forexample:openames,an
operatinggasapplianceoranoperatingelectricheater).
• Donotpierceorburn.
• Beawarethatrefrigerantsmaynotcontainanodour.
• Theappliancemustbeinstalled,operatedandstoredinaroomwithaoorarealargerthan12.4m
2.Maintainan
installationheightof2.5mormorefromtheoorsurfacetothebottomoftheappliance.Ifthesizeoftheroomwhere
theapplianceistobeinstalledhaslessthantheindicatedminimumoorarea,installitinawellventilatedroom.
• Toavoidre,explosionorinjury,donotoperatetheunitwhenharmfulgases(e.g.ammableorcorrosive)aredetected
neartheunit.
• Beawarethatprolonged,directexposuretocoolorwarmairfromtheairconditioner,ortoairthatistoocoolortoo
warm,canbeharmfultoyourphysicalconditionandhealth.
• Donotplaceobjects,includingrods,yourngers,etc.,intheairinletoroutlet.Productdamageorpersonalinjurymay
resultduetocontactwiththeairconditioner’shigh-speedfanblades.
• Donotattempttorepair,dismantle,reinstallormodifytheairconditioneryourselfasthismayresultinwaterleakage,
electricshockorrehazards.
• Donotuseammablesprayneartheairconditioner,orotherwiseremayresult.
• Donotusearefrigerantotherthantheoneindicatedontheoutdoorunit(R32)wheninstalling,movingorrepairing.
Usingotherrefrigerantsmaycausetroubleordamagetotheunit,andpersonalinjury.
• Toavoidelectricshock,donotoperatewithwethands.
Contents
Read Before Operation
SafetyPrecautions....................................... 1
NamesofParts............................................ 3
Multi Connection
NoteforMultiSystem.................................. 4
Care
CareandCleaning....................................... 6
When the Need Arises
Troubleshooting........................................... 8
Safety Precautions
1 English
WARNING
• Bewareofreincaseofrefrigerantleakage.Iftheairconditionerisnotoperatingcorrectly,i.e.notgeneratingcoolor
warmair,refrigerantleakagecouldbethecause.Consultyourdealerforassistance.Therefrigerantwithintheair
conditionerissafeandnormallydoesnotleak.
However,intheeventofaleakage,contactwithanakedburner,heaterorcookermayresultingenerationofnoxious
gas.Donotusetheairconditioneruntilaqualiedservicepersonconrmsthattheleakagehasbeenrepaired.
•
Donotattempttoinstallorrepairtheairconditioneryourself.Improperworkmanshipmayresultinwaterleakage,electric
shockorrehazards.Pleasecontactyourlocaldealerorqualiedpersonnelforinstallationandmaintenancework.
• Iftheairconditionerismalfunctioning(givingoffaburningodour,etc.),turnoffpowertotheunitandcontactyourlocal
dealer.Continuedoperationundersuchcircumstancesmayresultinafailure,electricshockorrehazards.
•
Besuretoinstallanearthleakagecircuitbreaker.Failuretoinstallanearthleakagecircuitbreakermayresultinelectricshockorre.
• Besuretoearththeunit.Donotearththeunittoautilitypipe,lightningconductorortelephoneearthlead.Imperfect
earthingmayresultinelectricshock.
CAUTION
• Donotusetheairconditionerforpurposesotherthanthoseforwhichitisintended.Donotusetheairconditionerfor
coolingprecisioninstruments,food,plants,animalsorworksofartasthismayadverselyaffecttheperformance,
qualityand/orlongevityoftheobjectconcerned.
• Donotexposeplantsoranimalsdirectlytotheairowfromtheunitasthismaycauseadverseeffects.
• Donotplaceappliancesthatproducenakedamesinplacesexposedtotheairowfromtheunitasthismayimpair
combustionoftheburner.
• Donotblocktheairinletsnoroutlets.Impairedairowmayresultininsufcientperformanceortrouble.
• Donotsitontheoutdoorunit,putthingsontheunit,orpulltheunit.Doingsomaycauseaccidents,suchasfallingor
topplingdown,thusresultingininjury,productmalfunctioning,orproductdamage.
• Donotplaceobjectsthataresusceptibletomoisturedirectlybeneaththeindoororoutdoorunits.Undercertain
conditions,condensationonthemainunitorrefrigerantpipes,airlterdirtordrainblockagemaycausedripping,
resultinginfoulingorfailureoftheobjectconcerned.
• Afterprolongeduse,checktheunitstandanditsmountsfordamage.Iftheyareleftinadamagedcondition,theunit
mayfallandcauseinjury.
• Toavoidinjury,donottouchtheairinletoraluminiumnsoftheindoororoutdoorunits.
• Theapplianceisnotintendedforusebyunattendedyoungchildrenorinrmpersons.Impairmentofbodilyfunctions
andharmtohealthmayresult.
• Childrenshouldbesupervisedtoensurethattheydonotplaywiththeunitoritsremotecontroller.Accidentaloperation
byachildmayresultinimpairmentofbodilyfunctionsandharmhealth.
• Avoidimpactstotheindoorandoutdoorunits,orotherwiseproductdamagemayresult.
• Donotplaceammableitems,suchasspraycans,within1moftheairoutlet.
Thespraycansmayexplodeasaresultofhotairfromtheindoororoutdoorunits.
•
Becarefulnottoletpetsurinateontheairconditioner.Urinationontheairconditionermayresultinelectricshockorre.
• Donotwashtheairconditionerwithwater,asthismayresultinelectricshockorre.
•
Donotplacewatercontainers(vases,etc.)abovetheunit,asthismayresultinelectricshockorrehazardsiftheyshouldtoppleover.
•
Donotinsertthebatteriesinthewrongpolarity(+/-)orientationasthismayresultinshortcircuiting,re,orbatteryleakage.
• Toavoidoxygendepletion,ensurethattheroomisadequatelyventilatedifequipmentsuchasaburnerisused
togetherwiththeairconditioner.
•
Beforecleaning,besuretostopunitoperationandturnoffthecircuitbreaker.Otherwise,anelectricshockandinjurymayresult.
• Onlyconnecttheairconditionertothespeciedpowersupplycircuit.Powersuppliesotherthantheonespeciedmay
resultinelectricshock,overheatingandres.
•
Arrangethedrainhosetoensuresmoothdrainage.Imperfectdrainagemaycausewettingofthebuilding,furniture,etc.
• Donotplaceobjectsindirectproximityoftheoutdoorunitanddonotletleavesandotherdebrisaccumulatearound
theunit.Leavesareahotbedforsmallanimalswhichcanentertheunit.Onceinsidetheunit,suchanimalscancause
malfunctions,smokeorreiftheycomeintocontactwithelectricalparts.
• Donotplaceobjectsaroundtheindoorunit.
Doingsomayhaveanadverseinuenceontheperformance,productquality,andlifeoftheairconditioner.
• Thisapplianceisnotintendedtobeusedbypersonswithreducedphysical,sensoryormentalcapabilities,orwithlack
ofoperationknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerningtheapplianceuseby
personresponsiblefortheirsafety.Keepoutofchildrensreachtoensurethattheydonotplaywiththeappliance.
• Forcareandcleaning,callservicepersonnel.
FTP008
Thisisanappliancethatisnotaccessibletothegeneralpublic.
Precautions relating to area surrounding the indoor and outdoor units
Besuretofollowtheinstructionsbelow.
• Theindoorunitisatleast1mawayfromanytelevisionorradioset(unitmaycauseinterferencewiththepictureorsound).
• Refrainfromusingtheunitsinareaspronetohighlevelsofoilysmoke,suchasakitchen.Waterleakagemayresult.
English 2
Indoor Unit a
b
c
d
e
f
g
h
i
j
k
l
m
aDraindischargedevice(built-in) Refrigerantpipingg
bDrainpaninspectionwindow Drainpipingh
c
Remotecontroller(Wiredtype)
Theappearanceoftheremotecontrollermaydifferbetween
differentmodels.
iModelname(Modelnameplate)
jAirfilter(Soldseparately)
kSuctionfilterchamber(Soldseparately)
dWiringbetweentheindoorandoutdoorunits Suctionduct(Fieldsupply)l
eAiroutletgrille(Fieldsupply) Suctiongrille(Fieldsupply)m
fExhaustduct(Fieldsupply)
Names of Parts
Outdoor Unit
 •Theappearanceoftheoutdoorunitmaydifferbetweendifferentmodels.
Earth terminal (inside)
Refrigerant pipes and
inter-unit wire
Air outlet
Air inlet (back and side)
Model name
Drain hose
Wired type Wireless type
Remote controller
•Fordetailsonremotecontrolleroperation,refertothe
operationmanualincludedwiththeremotecontroller.
3 English
Amultisystemhasoneoutdoorunitconnectedtomultipleindoorunits.
Selecting the operation mode
When the priority room setting is active
but the set unit is not operating or when
the priority room setting is inactive
Whenmorethanoneindoorunitisoperating,priorityisgivento
therstunitthatwasturnedon.
Inthiscase,settheunitsthatareturnedonlatertothesame
operationmodeastherstunit.
Otherwise,theywillenterthestandbystate,andwhenusingthewired
remotecontrollerthecentralizedcontrolicon“ ”willlightup;this
doesnotindicatemalfunction.
NOTE
Notes on operation mode for a multi system
•COOL,DRYandFANoperationmaybeusedatthesametime.
•AUTOoperationautomaticallyselectsCOOLoperationorHEAToperationbasedontheindoortemperature.
Therefore,AUTOoperationisavailablewhenselectingthesameoperationmodeasthatoftheroomwiththerstunittobeturnedon.
CAUTION
• Normally,theoperationmodeintheroomwheretheunitisrststartedisgivenpriority,butthefollowingsituationsareexceptionstothisrule.
IftheoperationmodeoftherstroomisFANoperation,thenusingHEAToperationinanyroomafterthiswillgiveprioritytoHEAToperation.In
thissituation,theindoorunitoperatinginFANmodewillswitchtostandby,andwhenusingthewiredremotecontrollerthecentralizedcontrol
iconwilllightup.
With the priority room setting active
Referto“Priority room settingonthenextpage.
NIGHT QUIET mode (Available only for COOL operation)
NIGHTQUIETmoderequiresinitialprogrammingduringinstallation.Pleaseconsultyourretailerordealerforassistance.
NIGHTQUIETmodereducestheoperationnoiseoftheoutdoorunitduringthenight-timehourstopreventannoyancetoneighbours.
• NIGHTQUIETmodeisactivatedwhenthetemperaturedrops6°Cormorebelowthehighesttemperaturerecordedthatday.
Whenthetemperaturedifferencebetweenthecurrentoutdoortemperatureandthemaximumoutdoortemperaturebecomeslessthan4°C,
thisfunctionwillbecancelled.
• NIGHTQUIETmodeslightlyreducesthecoolingefciencyoftheunit.
OUTDOOR UNIT QUIET operation (Function unavailable in the FMA series)
FordetailsonOUTDOORUNITQUIEToperation,refertotheoperationmanualincludedwiththeremotecontroller.
When the priority room setting is active but the set unit is not operating or when the
priority room setting is inactive
WhenusingtheOUTDOORUNITQUIEToperationfeaturewithamultisystem,setallindoorunitstoOUTDOORUNIT
QUIEToperationusingtheirremotecontrollers.
WhencancellingOUTDOORUNITQUIEToperation,simplycancelthemodeononeoftheoperatingindoorunitsusingtheirremotecontroller.
HoweverOUTDOORUNITQUIEToperationwillremaindisplayedontheremotecontrollersfortheotherrooms.
Werecommendyoucanceloperationinallroomsusingtheirremotecontrollers.
With the priority room setting active
Referto“Priority room settingonthenextpage.
Room A Room B
Room C Room D
Outdoor unit
Note for Multi System
English 4
COOL/HEAT mode lock
TheCOOL/HEATmodelockrequiresinitialprogrammingduringinstallation.Pleaseconsultyourauthorizeddealerfor
assistance.TheCOOL/HEATmodelocksetstheunitforciblytoeitherCOOLorHEAToperation.Thisfunctionisconvenient
whenyouwishtosetallindoorunitsconnectedtothemultisystemtothesameoperationmode.
NOTE
•TheCOOL/HEATmodelockcannotbeactivatedtogetherwiththepriorityroomsetting.
Priority room setting
Thepriorityroomsettingrequiresinitialprogrammingduringinstallation.Pleaseconsultyourauthorizeddealerforassistance.
Theroomdesignatedasthepriorityroomtakespriorityinthefollowingsituations.
Operation mode priority
•Astheoperationmodeofthepriorityroomtakesprecedence,youcanselectadifferentoperationmodefromother
rooms.
[Example]
•RoomAisthepriorityroominthisexample.
WhenCOOLoperationisselectedinroomAwhileoperatingthefollowingmodesinroomB,CandD:
Operation mode in room B, C and D Status of room B, C and D when the unit in room A is in COOL operation
COOLorDRYorFAN Thecurrentoperationmodeismaintained.
HEAT Theunitentersthestandbymode.OperationresumeswhentheroomAunitstopsoperating.
AUTO IftheunitissettoCOOLoperation,itcontinues.IftheunitissettoHEAToperation,itentersthe
standbymode.OperationresumeswhentheroomAunitstopsoperating.
Priority when SUPER POWERFUL / HEAT PLUS operation is used
(Function unavailable in the FMA series)
[Example]
•RoomAisthepriorityroominthisexample.
TheindoorunitsinroomsA,B,CandDarealloperating.IftheunitinroomAentersSUPERPOWERFUL/HEATPLUS
operation,operationcapacitywillbeconcentratedinroomA.Insuchacase,thecooling(heating)efciencyoftheunitsin
roomB,CandDmaybeslightlyreduced.
Priority when OUTDOOR UNIT QUIET operation is used
(Function unavailable in the FMA series)
[Example]
•RoomAisthepriorityroominthisexample.
JustbysettingtheunitinroomAtoQUIEToperation,theairconditionerstartsOUTDOORUNITQUIEToperation.
YoudonothavetosetalltheindoorunitsinoperationtoOUTDOORUNITQUIEToperation.
Note for Multi System
5 English
CAUTION
• Onlyaqualiedservicepersonisallowedtoperformmaintenance.
• Beforecleaning,besuretostoptheoperationandturnoffthecircuitbreaker.
• Donottouchthealuminiumnsoftheindoorunit.Ifyoutouchthoseparts,thismaycauseaninjury.
How to clean the air  lter
Whentheremotecontrollerindicates“Timetocleanfilter”,cleantheairfilter.
• Itindicatesafterrunningforacertaintime.
NOTE
For cleaning, do not use any of the following:
•Waterhotterthan40°C
•Volatileliquidsuchasbenzine,petrolandthinner
•Polishingcompounds
•Roughmaterialssuchasascrubbingbrush
•Youmaychangethetimeofindication“Timetocleanfilter”.
If the indoor unit is used in a space where the air is too contaminated, ask your local dealer for solution.
Contamination Timeuntilindicationisdisplayed
Normal 2500hours
(equivalenttooneyear)
Morecontaminated 1250hours
(equivalenttoahalfyear)
•Ifitbecomesdifculttoremovecontaminationfromtheairlter,replacetheairlter.
(Airlterforreplacementisaseparatelysoldaccessory)
•Donotremovetheairlterexceptwhencleaning.Unnecessaryhandlingmaydamagethelter.
(Thisproductisnotprovidedwithanairlterasastandardaccessory.)
•Donotattachobjectsotherthanthegenuineairlter(e.g.,kitchenpaper)totheairinlet.
Otherwise,theperformanceoftheairconditionerwillbedegraded,andicingorwaterleakagemayresult.
•Thisproductisaceilingmountedducttypeairconditioner.
Installing under roof
Iftheairfilter(soldseparately)isused,requestaspecialcontractorforthecleaningoftheairfilter.
Not installing under roof
Alwaysusethelong-lifefilterchamber(soldseparately).Besuretorequestyourdealerfortheinstallationofthelong-lifechamber.Forthemethods
ofmounting,dismounting,andcleaningtheairfilter,refertothemanualprovidedwiththeairfilter.
Be sure to use the separately sold lter chamber.
Requestyourdealerfortheinstallationofthefilterchamber.
•Besuretocleantheairlteratthebeginningofthecoolingorheatingseason.
(Adecreaseintheairowvolumeoftheairconditionerwillresultandtheperformanceoftheairconditionerwillbedegradediftheairlterisclogged
withdustordirt.)
Increasethefrequencyofcleaningiftheunitisinstalledinaroomwheretheairisextremelycontaminated.
After completing cleaning and installing an air filter, turn off the indication of “Time to clean filter” on the remote controller.
• PresstheFILTERSIGNRESETbutton.
• Theindicationcanbeturnedoffwhiletheunitiseitheroperatingorstopped.
Care and Cleaning
English 6
How to clean air outlet, outside panels and remote controller
1. Clean with soft cloth.
2. When it is difcult to remove stains, use water or neutral
detergent.
NOTE
Do not wash the suction grille with water of 50°C or higher.
It may cause discoloration and deformation.
When drying the suction grille, do not heat it with re. It may cause burning.
Do not use substances such as gasoline, benzine, thinner, polishing powder and liquid insecticide sold in the market.
It may cause discoloration and deformation.
Prior to a long period of non-use
1. Operate the FAN mode for several hours on a ne day to dry out
the inside.
1) Pressthe“MODE”selectorbuttonandselect“FAN”operation.
•Whenamultioutdoorunitisconnected,makesuretheHEAToperationisnotbeingusedinotherroomsbeforeyou
usetheFANoperation. Page 4
2) Pressthe“ON/OFF”buttonandstartoperation.
2. After operation stops, turn off the circuit breaker for the room
air conditioner.
3. Clean the air lters and reattach them. Page 6
4. To prevent battery leakage, take out the batteries from the
remote controller. (Only for the wireless remote controller)
We recommend periodical maintenance
•Incertainoperatingconditions,theinsideoftheairconditionermaygetfoulafterseveralseasonsofuse,resultinginpoor
performance.Itisrecommendedtohaveperiodicalmaintenancebyaspecialist.
•Forspecialistmaintenance,pleasecontactthedealerwhereyouboughttheairconditioner.
•Themaintenancecostmustbebornebytheuser.
Care and Cleaning
7 English
Beforemakinganinquiryorarequestforrepair,pleasecheckthefollowing.
Iftheproblempersists,consultyourdealer.
Not a problem
Thiscaseisnotaproblem.
Check
Pleasecheckagainbeforerequesting
repairs.
Case Description / what to check
Operation does not start soon.
•
WhenON/OFFbuttonwaspressed
soonafteroperationwasstopped.
•Whenthemodewasreselected.
•Thisistoprotecttheairconditioner.
Youshouldwaitforabout3minutes.
Air does not come out.
In HEAT operation
•Theairconditioneriswarmingup.Waitforabout1to4minutes.
•Duringdefrostingoperation,hotairdoesnotowoutoftheindoorunit.
When the air conditioner operates immediately after the circuit breaker is turned on
•Theairconditionerispreparingtooperate.Waitforabout3to20minutes.
The heating operation stops suddenly
and a fl owing sound is heard.
•Thesystemistakingawaythefrostontheoutdoorunit.
Youshouldwaitforabout4to12minutes.
The outdoor unit emits water or
steam.
InHEATmode
 •Thefrostontheoutdoorunitmeltsintowaterorsteamwhentheairconditionerisindefrost
operation.
InCOOLorDRYmode
 •
Moistureintheaircondensesintowateronthecoolsurfaceofoutdoorunitpipinganddrips.
Mist comes out of the indoor unit. Thishappenswhentheairintheroomiscooledintomistbythecoldairowduringcooling
operation.
The indoor unit gives out odour.
Thishappenswhensmellsoftheroom,furniture,orcigarettesareabsorbedintotheunitand
dischargedwiththeairow.
(Ifthishappens,werecommendyoutohavetheindoorunitwashedbyatechnician.Consult
theserviceshopwhereyouboughttheairconditioner.)
The outdoor fan rotates while the
air conditioner is not in operation.
Afteroperationisstopped:
 •Theoutdoorfancontinuesrotatingforanother30secondsforsystemprotection.
Whiletheairconditionerisnotinoperation:
 •
Whentheoutdoortemperatureisveryhigh,theoutdoorfanstartsrotatingforsystemprotection.
The operation stopped suddenly.
(OPERATION lamp is on.)
Forsystemprotection,theairconditionermaystopoperatingonasuddenlargevoltageuctuation.
Itautomaticallyresumesoperationinabout3minutes.
The air conditioner does not
operate.
(OPERATION lamp is off.)
•Hasn’tabreakerturnedOFForafuseblown?
•Isn’titapowerfailure?
•Arebatteriessetintheremotecontroller?
•Isthetimersettingcorrect?
Cooling (Heating) effect is poor.
• Aretheairltersclean?
• Isthereanythingblockingtheairinletortheoutletoftheindoorandtheoutdoorunits?
• Isthetemperaturesettingappropriate?
• Arethewindowsanddoorsclosed?
• Aretheairowrateandtheairdirectionsetappropriately?
Operation stops suddenly.
(OPERATION lamp fl ashes.)
• Aretheairltersclean?
• Isthereanythingblockingtheairinletortheoutletoftheindoorandtheoutdoorunits?
CleantheairltersortakeallobstaclesawayandturnthebreakerOFF.ThenturnitONagain
andtryoperatingtheairconditionerwiththeremotecontroller.Ifthelampstillblinks,callthe
serviceshopwhereyouboughttheairconditioner.
•
Areoperationmodesallthesameforindoorunitsconnectedtooutdoorunitsinthemulti system?
Ifnot,setallindoorunitstothesameoperationmodeandconrmthatthelampsblink.
Moreover,whentheoperationmodeisin“AUTO”,setallindoorunitoperationmodesto
“COOLor“HEAT”foramomentandcheckagainthatthelampsarenormal.
Ifthelampsstopblinkingaftertheabovesteps,thereisnomalfunction.
Troubleshooting
English 8
Case Description / what to check
An abnormal functioning
happens during operation.
• Theairconditionermaymalfunctionwithlightningorradiowaves.TurnthebreakerOFF,turnit
ONagainandtryoperatingtheairconditionerwiththeremotecontroller.
Notes on the operating conditions
•Ifoperationcontinuesunderanyconditionsotherthanthoselistedinthetable,
−Asafetydevicemayactivatetostoptheoperation.
−DewmayformontheindoorunitanddripfromitwhenCOOLorDRY
operationisselected.
Mode Operating conditions
COOL / DRY
Outdoortemperature:
 [HEATPUMPmodel]:–10.0-46.0°C
 [COOLINGONLYmodel]:10.0-46.0°C
Indoortemperature:18.0-32.0°C
Indoorhumidity:80%max.
HEAT Outdoortemperature:–15-24°C
Indoortemperature:10-30°C
Call your dealer immediately
WARNING
When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.
• Continuedoperationinanabnormalconditionmayresultinproblems,electricshockorre.
• Consultthedealerwhereyouboughttheairconditioner.
Do not attempt to repair or modify the air conditioner by yourself.
• Incorrectworkmayresultinelectricshockorre.
• Consultthedealerwhereyouboughttheairconditioner.
If one of the following symptoms takes place, call your dealer immediately.
The power cord is abnormally hot or damaged.
An abnormal sound is heard during operation.
The circuit breaker, a fuse, or the earth leakage circuit
breaker cuts off the operation frequently.
A switch or a button often fails to work properly.
There is a burning smell.
Water leaks from the indoor unit.
Turnoffthecircuitbreakerandcallyourdealer.
After a power failure
 •Theairconditionerautomaticallyresumesoperationinabout3minutes.Youshouldjustwaitforawhile.
Lightning
 •Ifthereisarisklightningcouldstrikeintheneighbourhood,stopoperationandturnoffthecircuitbreakertoprotectthe
system.
Disposal requirements
 •Dismantlingoftheunit,handlingoftherefrigerant,oilandotherparts,shouldbedoneinaccordancewiththerelevantlocal
andnationalregulations.
Troubleshooting
9 English
The two-dimensional bar code is
a manufacturing code.
3P472684-6 M16B253 (1705) HT
WIRELESS REMOTE CONTROLLER KIT
OPERATION MANUAL
MODELS
BRC086A21
BRC086A22
Fig. 1-1
13
2
6
1
3
7
8
12
10
9
11
4
5
Fig. 1-2
18
14
19
17
20
15
16
Fig. 2
CEILING MOUNTED CASSETTE TYPE (2x2)
(Sold separately)
SIGNAL RECEIVER UNIT SEPARATE TYPE
(Sold separately)
Receiver
21
25
22
23
24
26
[1]
ACCESSORIES
Check if the following accessories are attached to this kit.
Name (1) Wireless remote
controller
(2) Remote controller
holder
(3)
Dry cell battery
AAA. LR03 (alkaline)
Quantity 1 1 2
Shape
Name
(4) Operation manual (5) Remote controller
holder xing screw
M3 × 20L
Quantity 1 2
Shape
[2]
PRIOR TO USE
This operation manual is exclusively for instructions on how to use the wireless remote controller.
Read also the operation manual attached to the indoor unit and to the outdoor unit for safe usage of the
system and maintenance.
CONTENTS
ILLUSTRATIONS [1]
.......................................................
ACCESSORIES [2]
.........................................................
PRIOR TO USE ...........................................................
1
1. SAFETY PRECAUTIONS .....................................
1
2. WHAT TO DO BEFORE OPERATION ..................
3
3. NAMES AND FUNCTIONS OF THE
OPERATING SECTION
(Refer to Fig. 1-1, 1-2, 2 on page [1]) .....................
3
4. HANDLING FOR WIRELESS REMOTE
CONTROLLER .....................................................
4
5. OPERATION RANGE ...........................................
5
6. INSTALLATION SITE ............................................
5
7. OPERATION PROCEDURE .................................
5
8. OPERATION CHARACTERISTICS ....................
11
9. OPTIMUM OPERATION .....................................
11
10. MAINTENANCE
(FOR SERVICE PERSONNEL) ..........................
11
11. NOT MALFUNCTION OF THE AIR
CONDITIONER ..................................................
11
12. HOW TO DIAGNOSE TROUBLE SPOTS ...........
11
13. HOW TO CHECK THE INITIAL SET VALUE .......
13
1. SAFETY PRECAUTIONS
•Keepthismanualwheretheusercaneasilyndit.
•TheprecautionsdescribedhereinareclassiedasWARNINGandCAUTION.Theybothcontain
important information regarding safety. Be sure to observe all precautions without fail.
WARNING CAUTION
Failure to follow these instructions properly may result
in personal injury or loss of life.
Failure to follow these instructions properly may result in
property damage or personal injury, which may be
serious depending on the circumstances.
Never attempt. Be sure to follow the
instructions.
Be sure to establish an
earth connection.
•After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If
the equipment is transferred to a new user, be sure also to hand over the manual.
WARNING
•Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer.
•The appliance must be stored in a room without continuously operating ignition sources (for example: open
ames,anoperatinggasapplianceoranoperatingelectricheater).
•Do not pierce or burn.
•Be aware that refrigerants may not contain an odour.
•Toavoidre,explosionorinjury,donotoperatetheunitwhenharmfulgases(e.g.ammableorcorrosive)
are detected near the unit.
•Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too
cool or too warm, can be harmful to your physical condition and health.
•Donotplaceobjects,includingrods,yourngers,etc.,intheairinletoroutlet.Productdamageor
personal injury may result due to contact with the air conditioner’s high-speed fan blades.
•Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result in
waterleakage,electricshockorrehazards.
•Donotuseammablesprayneartheairconditioner,orotherwiseremayresult.
•Do not use a refrigerant other than the one indicated on the outdoor unit when installing, moving or
repairing. Using other refrigerants may cause trouble or damage to the unit, and personal injury.
•To avoid electric shock, do not operate with wet hands.
1 English
WARNING
•Bewareofreincaseofrefrigerantleakage.Iftheairconditionerisnotoperatingcorrectly,i.e.not
generating cool or warm air, refrigerant leakage could be the cause. Consult your dealer for assistance.
The refrigerant within the air conditioner is safe and normally does not leak.
However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of noxious
gas.Donotusetheairconditioneruntilaqualiedservicepersonconrmsthattheleakagehasbeenrepaired.
•Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water
leakage,electricshockorrehazards.Pleasecontactyourlocaldealerorqualiedpersonnelfor
installation and maintenance work.
•If the air conditioner is malfunctioning (giving off a burning odour, etc.), turn off power to the unit and
contact your local dealer. Continued operation under such circumstances may result in a failure, electric
shockorrehazards.
•Be sure to install an earth leakage circuit breaker. Failure to install an earth leakage circuit breaker may
resultinelectricshockorre.
•Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead.
Imperfect earthing may result in electric shock.
CAUTION
•Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air
conditioner for cooling precision instruments, food, plants, animals or works of art as this may adversely
affect the performance, quality and/or longevity of the object concerned.
•Donotexposeplantsoranimalsdirectlytotheairowfromtheunitasthismaycauseadverseeffects.
•Donotplaceappliancesthatproducenakedamesinplacesexposedtotheairowfromtheunitasthis
may impair combustion of the burner.
•Donotblocktheairinletsnoroutlets.Impairedairowmayresultininsufcientperformanceortrouble.
•Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such
as falling or toppling down, thus resulting in injury, product malfunctioning, or product damage.
•Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under
certainconditions,condensationonthemainunitorrefrigerantpipes,airlterdirtordrainblockagemay
cause dripping, resulting in fouling or failure of the object concerned.
•After prolonged use, check the unit stand and its mounts for damage. If they are left in a damaged
condition, the unit may fall and cause injury.
•Toavoidinjury,donottouchtheairinletoraluminiumnsoftheindoororoutdoorunits.
•Theapplianceisnotintendedforusebyunattendedyoungchildrenorinrmpersons.Impairmentofbodily
functions and harm to health may result.
•Children should be supervised to ensure that they do not play with the unit or its remote controller.
Accidental operation by a child may result in impairment of bodily functions and harm health.
•Avoid impacts to the indoor and outdoor units, or otherwise product damage may result.
•Donotplaceammableitems,suchasspraycans,within1moftheairoutlet.
The spray cans may explode as a result of hot air from the indoor or outdoor units.
•
Becarefulnottoletpetsurinateontheairconditioner.Urinationontheairconditionermayresultinelectricshockorre.
•Donotwashtheairconditionerwithwater,asthismayresultinelectricshockorre.
•Donotplacewatercontainers(vases,etc.)abovetheunit,asthismayresultinelectricshockorre
hazardsiftheyshouldtoppleover.
•Donotinsertthebatteriesinthewrongpolarity(+/-)orientationasthismayresultinshortcircuiting,re,or
battery leakage.
•To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such as a burner is
used together with the air conditioner.
•
Before cleaning, be sure to stop unit operation and turn off the circuit breaker. Otherwise, an electric shock and injury may result.
•Onlyconnecttheairconditionertothespeciedpowersupplycircuit.Powersuppliesotherthantheone
speciedmayresultinelectricshock,overheatingandres.
•
Arrange the drain hose to ensure smooth drainage. Imperfect drainage may cause wetting of the building, furniture, etc.
•Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris
accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once inside
theunit,suchanimalscancausemalfunctions,smokeorreiftheycomeintocontactwithelectricalparts.
•Do not place objects around the indoor unit.
Doingsomayhaveanadverseinuenceontheperformance,productquality,andlifeoftheairconditioner.
•This appliance is not intended to be used by persons with reduced physical, sensory or mental capabilities,
or with lack of operation knowledge, unless they have been given supervision or instruction concerning the
appliance use by person responsible for their safety. Keep out of children’s reach to ensure that they do not
play with the appliance.
FTPF008-RC
English 2
2. WHAT TO DO BEFORE
OPERATION
Refer to the operation manual attached to the
indoor unit.
3. NAMES AND FUNCTIONS OF
THE OPERATING SECTION
(Refer to Fig. 1-1, 1-2, 2 on page
[1])
1DISPLAY (SIGNAL TRANSMISSION)
This blinks when a signal is being transmitted.
2
DISPLAY
(OPERATION MODE)
This display shows the current OPERATION
MODE. Operation modes supported depend on
the model that is connected.
3
DISPLAY “NOT AVAILABLE (displayed
when operation is not supported)
When a button for a function that is not
supported on the connected model is pressed,
this displays for 2 seconds.
4DISPLAY (SET TEMPERATURE)
This display shows the set temperature.
5
DISPLAY (PROGRAMMED TIME)
This display shows PROGRAMMED TIME of
the air conditioner start or stop.
6DISPLAY (AIRFLOW BLADE)
Refer to page 8, 9.
7DISPLAY (FAN SPEED)
The display shows the set fan speed.
8
DISPLAY (INSPECTION)
When the INSPECTION BUTTON is pressed,
the display shows the system mode is in.
Do not operate this button during normal use.
9
ON/OFF BUTTON
Press the button and the air conditioner
will start. Press the button again and the air
conditioner will stop.
10 FAN SPEED CONTROL BUTTON
Press this button to select the fan speed.
11 TEMPERATURE SETTING BUTTON
Use this button for SETTING TEMPERATURE.
12 BACKLIGHT BUTTON
Press this button to turn the backlight on or off.
13 SIGNAL TRANSMITTER
This sends the signals to the indoor unit.
14
PROGRAMMING TIMER BUTTON
Use this button for programming “START and/
or STOPtime.
15 TIMER MODE ON/OFF BUTTON
Refer to page 9.
16 TIMER RESERVE/CANCEL BUTTON
Refer to page 9.
17 AIRFLOW DIRECTION ADJUST BUTTON
Refer to page 8.
18
OPERATION MODE SELECTOR BUTTON
Press this button to select OPERATION MODE.
(COOLING), (HEATING),
(AUTOMATIC), (FAN),
(PROGRAMME DRY).
19
FILTER SIGN RESET BUTTON
Refer to the section of MAINTENANCE in the
operation manual attached to the indoor unit.
20
INSPECTION BUTTON
Thisbuttonisusedonlybyqualiedservice
persons for maintenance purposes.
Do not operate this button during normal use.
21
EMERGENCY OPERATION SWITCH
This switch is readily used if the remote
controller does not work.
22
RECEIVER
This receives the signals from the remote
controller.
23
OPERATING INDICATOR LAMP (Red)
This lamp stays lit while the air conditioner runs.
Itasheswhentheairconditionerisintrouble.
24 TIMER INDICATOR LAMP (Green)
This lamp stays lit while the timer is set.
25
AIR FILTER CLEANING TIME INDICATOR
LAMP (Red)
Lightsupwhenitistimetocleantheairlter.
26
DEFROST OPERATION LAMP (Orange)
Lights up when the defrosting operation has
started.
3 English
NOTE
•For the sake of explanation, all indications
are shown on the display in Fig. 1
contrary to
actual running situations.
•Fig. 1-2
shows the remote controller with the
front cover opened.
•If the AIR FILTER CLEANING TIME
INDICATORLAMPlightsup,cleantheairlter
as explained in the operation manual attached
to the indoor unit.
•Aftercleaningandreinstallingtheairlter,
press the FILTER SIGN RESET BUTTON
on the remote controller. The AIR FILTER
CLEANING TIME INDICATOR LAMP on the
receiver will go out.
•TheDEFROSTOPERATIONLAMPwillash
when the power is turned on. This is not a
malfunction.
•Do not place the remote controller where
subject to direct sunlight. The display of the
remote controller will get discolored and may
fail to display information.
[CAUTIONS]
Make sure to turn off the unit and
disconnect the power supply circuit
breaker when taking care of the air
conditioner.
Unless the power supply is disconnected,
it may cause electric shock and injuries.
4. HANDLING FOR WIRELESS
REMOTE CONTROLLER
[Precautions in handling remote controller]
Direct the transmitting part of the remote
controller to the receiving part of the air
conditioner.
If something blocks the transmitting and receiving
path of the indoor unit and the remote controller
as curtains, it will not operate.
2 short beeps
from the receiver
indicates that
the transmission
is properly done.
Types of receiving tone
The following receiving tones sound when remote
controller signals are detected by the receiver.
2 SHORT BEEPS:
Signal from the remote controller was received
successfully.
1 LONG BEEP:
(Error tone) The selected function is not
supported on this indoor unit.
3 SHORT BEEPS:
(Error tone) Setting/change cannot be made
using this remote controller as centralised control
is in operation.
NOTE
•After settings are changed or operation is
turned ON/OFF, make sure that the receiving
tone of the indoor unit makes a beeping sound.
The maximum transmitting distance is 7 to 9m.
This depends on the installation condition of the
indoor unit.
Do not drop or get it wet.
It may be damaged.
Never press the button of the remote
controller with a hard, pointed object.
The remote controller may be damaged.
English 4
Installation site
• It is possible that signals will not be received in
roomsthathaveelectronicuorescentlighting.
Please consult with your local dealer before
buyingnewuorescentlights.
• If the remote controller operated some other
electrical apparatus, move that machine away
or consult your local dealer.
• Do not install the remote controller in places
exposed to direct sunlight. Doing so could
result in discolouration and failure of the LCD.
[CAUTIONS]
Incorrect handling of batteries can result
in injury from battery leakage, rupturing or
heating, or lead to equipment failure.
Please observe the following precautions and
use safely.
• If the alkaline solution from the batteries should
get in the eyes, do not rub the eyes. Instead,
immediately flush the eyes with tap water and
seek the attention of a medical professional.
• Keep batteries out of reach of children. In the
event that batteries are swallowed, seek the
immediate attention of a medical professional.
• Do not expose batteries to heat or fire. Do not
disassemble or modify batteries. The insulation
or gas release vent inside the battery may
be damaged, resulting in battery leakage,
rupturing, or heating.
• Do not damage or peel off labels on the
batteries.
To insert the batteries
Position and
correctly!
+
2
3
1
Grip both
sides of the
front cover.
1. Slide the front
cover to take
it off.
2. Insert2dry
batteries AAA.
LR03 (alkaline).
3. Replace the
front cover.
To attach the remote
controller holder to a wall
Remote
controller
holder
Remote
controller
Screws
1.
Choose a place
from where the
signals reach the
unit.
2.
Attach the holder
to a wall, a
pillar, or similar
location with the
screws supplied
with the holder.
3.
Place the remote
controller in the
remote controller
holder.
NOTE
Notes on batteries
• To avoid possible injury or damage from battery
leakage or rupturing, remove the batteries
when not using the product for long periods of
time.
• The standard replacement time is about 1 year.
Both batteries should be replaced at the same
time.Besuretoreplacethemwithnewsize
AAA.LR03 (alkaline) batteries.
• The batteries supplied with the remote
controller are for initial operation. The batteries
may run out in less than 1 year.
[CAUTIONS]
• Replace all batteries at the same time, do
not use new and old batteries intermixed.
• In case the remote controller is not used
for a long time take out all batteries in order
to prevent liquid leak of the battery.
IN THE CASE OF CENTRALIZED
CONTROL SYSTEM
Iftheindoorunitisundercentralizedcontrol,it
is necessary to switch the remote controller’s
setting.
In this case, contact your local dealer.
5. OPERATION RANGE
If the temperature or the humidity is beyond
the operation range*, safety devices may work
and the air conditioner may not operate, or
sometimes, water may drop from the indoor unit.
*Refer to the operation range shown in the
operation manual attached to the indoor or
outdoor unit.
6. INSTALLATION SITE
Refer to operation manual attached to the indoor
unit.
7. OPERATION PROCEDURE
• Operation procedure varies with heat pump
type and cooling only type. Contact your local
dealertoconrmyoursystemtype.
• To protect the unit, turn on the main power
switch 6 hours before operation.
• Do not shut off the power supply during
seasonal use of the air conditioner.
This is required in order to activate the air
conditioner smoothly.
• If the main power supply is turned off during
operation, operation will restart automatically
after the power turns back on again.
5 English
COOLING, HEATING, AUTOMATIC, FAN,
AND DRY OPERATION
Operate in the following order.
• Operation modes supported depend on the
model that is connected.
• For cooling only type, “COOLING”, and “FAN”
and “DRY” operation are able to select.
FOR SYSTEMS WITHOUT COOL/HEAT
CHANGEOVER REMOTE CONTROL
SWITCH
Refer to Fig. 1-2 on page [1]
1OPERATION MODE
SELECTOR
Press OPERATION MODE SELECTOR
button several times and select the
OPERATION MODE of your choice as
follows.
COOLING OPERATION �������
The recommended set temperature is 26 to 28°C.
HEATING OPERATION �������
The recommended set temperature is 18 to 23°C.
AUTOMATIC OPERATION ������
• In this operation mode, COOLING/HEATING
changeover is automatically conducted.
• AUTOMATIC OPERATION controls the
temperature based on the set temperature,
so it maintains a comfortable temperature
throughout the year.
<Example>
When the indoor temperature decreases
to 23°C or less when the set temperature
is at 25°C in the AUTOMATIC COOLING
OPERATION, the operation is changed over
to the AUTOMATIC HEATING OPERATION.
When the indoor temperature reaches 27°C
or more, the operation is changed over to the
AUTOMATIC COOLING OPERATION.
FAN OPERATION
����������
Air in the room is circulated.
DRY OPERATION ���������
• This operation is to decrease the humidity
in your room with the minimum temperature
decrease.
• The set point is the air temperature when
starting operation by DRY operation.
• Micro computer automatically determines
TEMPERATURE and FAN SPEED.
• DRY operation will not activate when room
temperature is 16°C or less.
2ON/OFF
Press ON/OFF button.
OPERATING INDICATOR LAMP (Red) lights
up or goes off and the system starts or stops
OPERATION.
• The fan may keep on running for about 1
minute after the heating operation stops for
removing the heat in the indoor unit.
NOTE
• Do not turn OFF power immediately after the
unit stops. Then, wait no less than 5 minutes.
Water is leaking or there is something else
wrong with the unit.
CHARACTERISTICS OF THE COOLING
OPERATION (COOLING OPERATION
AND AUTOMATIC COOLING OPERATION)
• Aftercontinuousoperationwiththeairow
horizontallyordownward,theairconditioner
operateswithdifferentairowdirectionfora
certain period of time to prevent condensation
build-upontheairowdirectionblades.(The
remotecontrollerdisplaystheairowdirection
that is set.)
• If the COOLING OPERATION is used when
the indoor temperature is low, frost adheres to
the heat exchanger of the indoor unit. This can
decrease the cooling capacity. In this case, the
system automatically switches to DEFROST
OPERATION for a while.
During DEFROST OPERATION, the low fan
speed is used to prevent the discharge of melt
water. (The remote controller displays the fan
speed that is set.)
• When the outside temperature is high, it takes
some time until the indoor temperature reaches
the set temperature.
English 6
CHARACTERISTICS OF THE HEATING
OPERATION (HEATING OPERATION AND
AUTOMATIC HEATING OPERATION)
START OF OPERATION
•
It generally takes a longer time for indoor
temperature of the HEATING OPERATION
to reach the set temperature compared to
the COOLING OPERATION. It is advisable to
start operation in advance using the TIMER
OPERATION.
After operation is stopped
•The fan operates for about 1 minute to dispel
heat inside the indoor unit.
Perform the following operation to prevent
heating capacity decrease and discharge of
cool air.
AT THE START OF OPERATION AND
AFTER DEFROST OPERATION
•A warm air circulating system is employed,
and therefore it takes some time until the entire
room is warmed up after the start of operation.
•The indoor fan runs to discharge a gentle wind
automatically until the temperature inside the
air conditioner reaches a certain level. At this
time, the DEFROST OPERATION LAMP on the
light receiving unit indicator lights. Leave it as it
stands and wait for a while.
(The remote controller displays the fan speed
that is set.)
•Theairdischargedirectionbecomeshorizontal
to prevent a draft of cool air to the inhabitants.
(The remote controller will display the set
airowdirection.)
DEFROST OPERATION (Frost removal
operation for the outdoor unit)
•As the frost on the coil of an outdoor unit
increase, heating effect decreases and the
system goes into the DEFROST OPERATION.
•The warm air stops, and the DEFROST
OPERATION LAMP on the light receiving unit
turn on. (The remote controller displays the fan
speed that is set.)
•After maximum 10 minutes of the DEFROST
OPERATION, the air conditioner returns to the
HEATING OPERATION.
•Theairowdirectionbecomeshorizontal.(The
remotecontrollerdisplaystheairowdirection
that is set.)
•During or after the DEFROST OPERATION,
white mist comes out from the air inlet or outlet
of the air conditioner.
•A hissing and “Shuh” sound may be heard
during this particular operation.
Regarding outside air temperature and
heating capacity
•The heating capacity of the air conditioner
declines as the outside air temperature falls.
In such a case, use the air conditioner in
combination with other heating systems.
(When a combustion appliance is used,
ventilate the room regularly.)
Do not use the combustion appliance where
the air from the air conditioner is blown directly
toward it.
•When the warm air stays under the ceiling and
your feet are cold, we recommend that you use
a circulator (a fan to circulate the air inside the
room). For details, consult your local dealer.
•When the indoor temperature exceeds the
set temperature, the indoor unit discharges a
gentlebreeze(switchestogentlewind).The
airowdirectionbecomeshorizontal.(The
remote controller displays the fan speed and
airowdirectionthatareset.)
FAN OPERATION
•Only the fan inside the indoor unit operates,
and the air in the room is circulated.
CHARACTERISTICS OF THE DRY
OPERATION
•This operation lowers the humidity without
lowering the indoor temperature. The indoor
temperature when the operation button is
pressed will be the set temperature. At this
time, the fan speed and temperature are set
automatically, so the remote controller does not
display the fan speed and set temperature.
Toefcientlylowertheindoortemperatureand
humidity,rstusetheCOOLINGOPERATION
to lower the indoor temperature, and then
use the DRY OPERATION. When the indoor
temperatureislowered,airowfromtheindoor
unit may stop.
•When operating continuously at downward
airowdirection,airblowsintheautomatically
set direction for a period of time to prevent
condensationonthehorizontalblades.
•If the DRY OPERATION is used when the
indoor temperature is low, frost forms on the
heat exchanger of the indoor unit. In this case,
the system automatically switches to the
DEFROST OPERATION for a while.
7 English
ADJUSTMENT
For programming TEMPERATURE, FAN SPEED
and AIRFLOW DIRECTION, follow the procedure
shown below.
TEMPERATURE SETTING
Press TEMPERATURE SETTING button
and programme the set temperature.
Each time this button is pressed, set
temperature rises 1°C.
Each time this button is pressed, set
temperature lowers 1°C.
• Temperature cannot be set in FAN
OPERATION and DRY OPERATION modes.
In case of AUTOMATIC OPERATION
• In AUTOMATIC OPERATION mode, the
relative temperature as compared to the
standard set temperature is displayed.
Remote controller display
Set temperature [°C]
STD -3 19
STD -2 20
STD -1 21
STD 22
STD +1 23
STD +2 24
STD +3 25
NOTE
• The set temperature range of the remote
controller is 16°C to 32°C.
FAN SPEED CONTROL
Press FAN SPEED CONTROL button.
Fan speed can be selected.
• The micro computer may sometimes control
the fan speed in order to protect the unit.
• The fan speed may be changed automatically
depending on the indoor temperature.
The fan may be stopped, but this is normal.
• Itmaytakesometimeuntiltheairowswitchis
completed, but this is normal.
• Fan speeds supported depend on the model
that is connected.
• In (Auto), the fan speed is adjusted
according to the set temperature and the
temperature in the room.
However, in FAN OPERATION mode, fan
speedisxed.
• The fan speed will not be displayed if the indoor
unit does not have fan speed control function.
UP AND DOWN AIRFLOW
DIRECTION ADJUSTMENT
Theup/downairowdirectionpositionswitches
eachtimetheup/downairowdirectionbuttonis
pressed.
P0 P0 P1 P2
P0
Swing P4 P3
Movementoftheairowdirectionblades
Under the operating conditions described below,
airowdirectioniscontrolledautomatically,soit
maydifferfromtheairowdirectiondisplayedon
the remote controller.
Operating
conditions
When the room
temperature is
higher than the
set temperature
(for HEATING
OPERATION)
The air is blown
horizontallyso
thattheairowis
not directed at the
body.
When HEATING
OPERATION
starts and when
in DEFROST
OPERATION mode
(for HEATING
OPERATION)
The air is blown
horizontallysothat
thecoldairowis
not directed at the
body.
During continuous
operation with
the air blowing
downward or
horizontally
The air conditioner
operates with a
differentairow
direction for a
certain period of
time to prevent
condensation build-
upontheairow
direction blades.
* HEATING OPERATION mode includes cases in
which operation is set to ”.
English 8
Descriptionofairowdirectionsettings
and operation
Therangeofmovementoftheairowdirection
blades varies by indoor unit model. Consult the
dealer of purchase for details.
Airow
direction
settings
Ceiling Mounted Cassette
(Round Flow, 4-way Flow, 2-way Flow)
4-Way Blow Ceiling Suspended
Up/downairow
Fixed
Theairowdirectioncanbexedinany
position in the range Position 0 to Position 4.
Indoor unit
(Desired position) (Desired position)
Swing
Theairowdirectionblades
automatically move up and down within
the range of Position 0 to Position 4.
Indoor unit
(Swing) (Swing)
Automatic
Theairowdirectionchangesautomatically
according to the temperature of the room.
However, during FAN OPERATION, the
airowdirectionissettoPosition0.
* Depending on the model, it may not
be possible to use this function.
PROGRAMME TIMER OPERATION
Operate in the following order.
•The timer is operated in the following 2 ways.
Programming the stop time ( OFF)
.... The air conditioner stops operating after the
set time has elapsed.
Programming the start time ( ON)
.... The air conditioner starts operating after the
set time has elapsed.
•The start and the stop time can be
simultaneously programmed.
•The timer setting is effective only once. When
using the TIMER operation every day, the
setting is required before each use.
Setting the timer
1TIMER MODE ON/OFF
Press the TIMER MODE ON/OFF button.
Thedisplayashes.
For setting the timer stop .... OFF”
For setting the timer start .... ON”
2PROGRAMMING TIMER
Press the PROGRAMMING TIMER button
and set the time for stopping or starting the
air conditioner.
When this button is pressed, the time
advances by 1 hour.
When this button is pressed, the time
goes backward by 1 hour.
•Keep pressing the button to change the
setting time continuously.
•The timer can be programmed a maximum
of 72 hours.
3TIMER RESERVE
Press the TIMER RESERVE button.
The timer setting procedure ends.
Thedisplaychangesfromashinglighttoa
constant light.
•Make sure that the receiving tone of the
indoor unit makes a beeping sound.
If the receiving tone does not sound, cancel
the timer according to the steps below, and
then set the timer following steps 1 to 3
above again.
Cancelling the timer
1ON/OFF TIMER
When the on TIMER MODE ON/OFF button
ispressed,thescreendisplayashesas
described below.
For the off timer .... OFF”
For the on timer .... ON”
2TIMER CANCEL
When the TIMER CANCEL button is
pressed, the timer setting that is blinking is
cancelled.
•Check that the indoor unit’s receiving tone
beeps twice. If the receiving tone does not
sound, select the timer you want to cancel
again, and then cancel it.
9 English
For example.
When the timer is
programmed to stop the
system after 3 hours and
start the air conditioner
after 4 hours, the air
conditioner will stop after
3 hours and then 1 hour
later the air conditioner
will start.
NOTE
• After the timer is programmed, the display
shows the remaining time.
EMERGENCY OPERATION
When the remote controller does not work due
to battery failure or the absence thereof, use the
switch on the receiver of the indoor unit. When
the remote controller does not work, even if the
batteries are replaced, contact your local dealer.
[START]
1Press the EMERGENCY OPERATION
SWITCH on the receiver.
• The air conditioner operates in the previous
mode.
• The air conditioner operates with the previously
set fan speed.
1 2
Location of this display varies by model. (Refer to
Fig. 2 on page [1])
[STOP]
2Press the EMERGENCY OPERATION
SWITCH again.
PRECAUTIONS FOR 2 REMOTE
CONTROLLER CONTROL SYSTEM
This system provides 2 other control systems
beside individual control (1 remote controller
controls1indoorunit)system.Conrmthe
following if your system is of the following control
system type.
2 remote controller control system
2 remote controllers (wired and wireless)
control 1 indoor unit.
The air conditioner follows individual operation.
• Cannot have 2 remote controller control system
with only wireless remote controllers. (It will be
a 2 remote controller control system having 1
wired and 1 wireless remote controllers.)
• Under 2 remote controller control system,
wireless remote controller cannot control timer
operation.
•
When set the timer by the wired remote controller,
the TIMER INDICATOR LAMP (Green) of the
receiver of the indoor unit is not light up.
• If the wired remote controller is used for
operation, the display on the wireless remote
controller does not change.
Indoor unit
Remote controller
NOTE
• Contact your local dealer in case of changing
the combination or setting of 2 remote
controller control systems.
• Please do not change the combination and
settings for the 2 remote controller control
systems by yourself, but be sure to ask your
local dealer.
English 10
8. OPERATION
CHARACTERISTICS
Refer to the operation manual attached to the
indoor unit.
9. OPTIMUM OPERATION
Refer to the operation manual attached to the
indoor unit.
10. MAINTENANCE
(FOR SERVICE PERSONNEL)
Refer to the operation manual attached to the
indoor unit.
11. NOT MALFUNCTION OF THE
AIR CONDITIONER
Refer to the operation manual attached to the
indoor unit.
And the following symptoms do not
indicate air conditioner malfunction
I. THE AIR CONDITIONER DOES NOT
OPERATE
• The receiving tone of the indoor unit
makes a triple beeping sound (normally,
beep-beep).
This is because the air conditioner is under
centralizedcontrol.
• After the HEATING OPERATION is
started, the DEFROST OPERATION LAMP
located on the indoor unit lights up.
The indoor fan runs to discharge a gentle wind
automatically until the temperature inside the
air conditioner reaches a certain level. At this
time, the DEFROST OPERATION LAMP on
the light receiving unit indicator lights. Leave it
as it stands and wait for a while.
II. COOLING AND HEATING OPERATIONS
CAN NOT BE SWITCHED
• The receiving tone of the indoor unit
makes a long beeping sound.
An unavailable mode was set for the indoor
unit under operation changeover control.
III. THERE IS NO DISPLAY OR ALL PARTS
ARE DISPLAYED
• When a button on the remote controller
is pressed.
The batteries have run out.
12. HOW TO DIAGNOSE TROUBLE
SPOTS
I. IN CASE BESIDES EMERGENCY STOP
1. The air conditioner does not operate at
all.
• Check if the receiver is exposed of sunlight
or strong light. Keep receiver away from
light.
• Check if there are batteries in the remote
controller. Place the batteries.
2. The air conditioner operates but it does
notsufcientlycoolorheat.
• Check if the set temperature is not proper.
(Refer to page 8)
• Check if the FAN SPEED is set to LOW
SPEED. (Refer to page 8)
• Checkiftheairowdirectionisnotproper.
(Refer to page 8, 9)
If the problem is not solved after checking
the above points, please do not try to repair
it yourself. In such cases, always consult
your local dealer. At this time, please tell the
symptom and model name (written on the
manufacturer’s label).
Contact your local dealer in the following case.
WARNING
When you detect a burning odour, shut
OFF power immediately and contact
your local dealer purchase. Using the
equipment in anything but proper working
condition can result in equipment damage,
electricshockand/orare.
11 English
II. EMERGENCY STOP
When the air conditioner stops in
emergency, the OPERATING INDICATOR
LAMP on the indoor unit starts blinking.
Take the following steps yourself to read
the malfunction code that appears on the
display. Contact your local dealer with this
code. It will help pinpoint the cause of the
trouble, speeding up the repair.
1
3 5
7
2 4
6
1
Press the INSPECTION button to select
the inspection mode .
appears on display and blinks.
“UNIT No. appears.
2
Press PROGRAMMING TIMER button and
change the unit number.
Press to change the unit number until the indoor
unit beeps and perform the following operation
according to the number of beeps.
Number of beeps
3 short beeps Perform all steps from
����
3
to
6
.
1 short beep ��� Perform 3 and 6 steps.
1 long beep Normal state ���
3
Press OPERATION MODE SELECTOR
button.
on the left-hand of the malfunction code
blinks.
4
Press PROGRAMMING TIMER button and
change the malfunction code.
Press until the indoor unit beeps twice.
5
Press OPERATION MODE SELECTOR
button.
on the right-hand of the malfunction code
blinks.
6
Press PROGRAMMING TIMER button and
change the malfunction code.
Press until the indoor unit makes a long beep.
Themalfunctioncodeisxedwhentheindoor
unit makes a long beep.
7Reset of the display
Press the OPERATION MODE SELECTOR
button to get the display back to the
normal state.
[Trouble]
The OPERATING INDICATOR LAMP of the
indoorunitisashingandtheunitdoesnotwork
at all. (Refer to page 3)
Malfunction
Code
INSPECTION display
Unit No.
which
sensed
trouble
English 12
[Remedial action]
Check the malfunction code on the remote
controller and contact your local dealer. (Refer to
page 12)
13. HOW TO CHECK THE INITIAL
SET VALUE
Further question regarding to the available
functions, contact your local dealer with your
initialsettingvalueconrmedbyusingtheremote
controller with the following steps.
1
Press the INSPECTION button to select
the inspection mode .
The initial set value
Press the button 2 times to return to
normal operation mode.
13 English
English 14
15 English
English 16
(1707) HT
3P477582-1 M16B306
The two-dimensional bar code is
a manufacturing code.


Product specificaties

Merk: Daikin
Categorie: Airco
Model: FMA60RVMA

Heb je hulp nodig?

Als je hulp nodig hebt met Daikin FMA60RVMA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Daikin

Handleiding Airco

Nieuwste handleidingen voor Airco