CyberPower PR750LCD3C Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor CyberPower PR750LCD3C (8 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 9 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
INTELLIGENT UPS SERIES
PR750LCD3C
USER MANUAL
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 | CyberPowerSystems.com
FEATURES
1 . Power Button/Power On Indicator
2 . Online Indicator
3 . On Battery Indicator
4 . Fault Indicator
5 . Battery Fault Indicator
6 . LCD Module Operation Buttons
7 . Cloud Monitoring (Ethernet Port)
8 . EPO (Emergency Power Oī˜Ÿ) Port
9 . Serial/USB Ports to PC
10 . TVSS Screw
11 . SNMP/HTTP Network Slot
12 . Circuit Breaker
13 . AC Input Power Cord
14 . Battery and Surge Protected Outlets
Menu Esc Enter
Input
120V~50/60Hz,12A
Push To
RESET
1 8 9
310
11
12
13
47
5
2
6
14
Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed power
protection, operation, and performance during the lifetime of the product. Please take a few minutes to
register your product at: www.CyberPowerSystems.com/registration.
Registration certiļ¬es your productā€™s warranty, conļ¬rms your ownership in the event of a product loss or theft,
and entitles you to free technical support. Register your product now to receive the beneļ¬ts of CyberPower
ownership.
PRODUCT REGISTRATION
CAUTION! To prevent the risk of ļ¬re or
electric shock, install in a temperature and humidity
controlled indoor area free of
conductive contaminants. (Please see
speciļ¬cations for acceptable temperature
and humidity range).
CAUTION! To reduce the risk of electric shock, do
not remove the cover except to service the battery.
Turn oī˜Ÿ and unplug the unit before
servicing the batteries. There are no user serviceable
parts inside except for the battery.
CAUTION! Hazardous live parts inside can be
energized by the battery even when the AC input
power is disconnected.
CAUTION! The UPS must be connected to an AC
power outlet with fuse or circuit breaker protection.
Do not plug into an outlet that is not grounded. If
you need to de-energize this equipment, turn oī˜Ÿ and
unplug the unit.
CAUTION! To avoid electric shock, turn oī˜Ÿ the unit
and unplug it from the AC power source before
servicing the battery or installing a computer
component.
CAUTION! To reduce the risk of ļ¬re, connect only to
a circuit provided with 20 amperes maximum branch
circuit over current protection in accordance with
the National Electric Code, ANSI/NFPA 70.
CAUTION! Not for use in a computer room as
deļ¬ned in the Standard for the Protection of
Electronic Computer/Data Processing Equipment,
ANSI/NFPA 75.
CAUTION! Do not dispose of batteries in a ļ¬re. The
batteries may explode.
CAUTION! The UPS should be near the connected
equipment and easily accessible.
DO NOT USE FOR MEDICAL
OR LIFE SUPPORT EQUIPMENT!
CyberPower Systems does not sell products for life
support or medical applications. DO NOT use in any
circumstance that would aī˜Ÿect operation and safety
of life support equipment, any medical applications
or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS!
To reduce the risk of ļ¬re or electric shock, do not use
with or near an aquarium. Condensation from the
aquarium can cause the unit to short out.
DO NOT USE THE UPS
ON ANY TRANSPORTATION!
To reduce the risk of ļ¬re or electric shock, do not use
the unit on any transportation such as airplanes or
ships. The eī˜Ÿect of shock or vibration caused during
transit and the damp environment can cause the unit
to short out.
IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or
operate your UPS.
INSTALLING YOUR UPS SYSTEM
UNPACKING
Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS unit
(b) Userā€™s manual
(c) Emergency power oī˜Ÿ cable (gray)
(d) USB A+B type cable
(e) Function setup guide
PowerPanelĀ® Business software is available
on our website. Please visit www.cyberpowersystems.
com and go to the Software Section for a free
download.
OVERVIEW
The PR750LCD3C provides complete power
protection from utility power that is not always
consistent.
The PR750LCD3C features 1030 Joules of surge
protection against power surges and maintenance
free batteries for long lasting battery backup during
power outages. In addition to ensuring consistent
power to your computer system, the PR750LCD3C
also includes software that will automatically save
your open ļ¬les and shutdown your computer system
during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The PR750LCD3C stabilizes inconsistent utility power
to nominal levels that are safe for equipment. Unstable
utility power can be damaging to important data and
hardware. With Automatic Voltage Regulation (AVR),
damaging voltage levels are corrected to safe levels.
AVR automatically increases low utility power to a
consistent and safe 110/120 volts.
INSTALLING YOUR UPS SYSTEM
DETERMINE THE POWER REQUIREMENTS OF YOUR
EQUIPMENT
1. Ensure that the
equipment plugged into
the UPS does not exceed
the UPS unitā€™s rated
capacity. If the rated
capacities of the unit are
exceeded, an overload
condition may occur and
cause the UPS unit to
shut down or the circuit breaker to trip.
2. There are many factors that can aī˜Ÿect the
amount of power that your electronic equipment
will require. For optimal system performance keep
the load below 80% of the unitā€™s rated capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately
upon receipt. However, to ensure the batteryā€™s
maximum charge capacity, it is recommended
that you charge the battery for at least 8 hours.
Your UPS is equipped with an auto-charge
feature. When the UPS is plugged into an AC
outlet, the battery will automatically charge
whether the UPS is turned on or oī˜Ÿ. Note: This
UPS is designed with a safety feature to keep the
system from being turned on during shipment.
The ļ¬rst time you turn the UPS on, you will need
to have it connected to AC power or it will not
power up.
2. With the UPS unit turned oī˜Ÿ and unplugged,
connect your computer, monitor, and any other
peripherals requiring battery backup into the
battery power supplied outlets. DO NOT plug
a laser printer, paper shredder, copier, space
heater, vacuum, sump pump or other large
electrical devices into the ā€œBattery and Surge
Protected Outletsā€. The power demands of these
devices may overload and damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded
receptacle (wall outlet). Make sure the wall
branch outlet is protected by a fuse or circuit
breaker and does not service equipment with
large electrical demands (e.g., air conditioner,
copier, etcā€¦). The warranty prohibits the use of
extension cords, outlet strips, and surge strips.
4. Press the power button and the enter button to
turn the unit on. The Power On indicator light will
illuminate. If an overload is detected, an audible
alarm will sound and the unit will emit one long
beep. To correct this, turn the UPS oī˜Ÿ and unplug
at least one piece of equipment from the battery
power supplied outlets. Make sure the circuit
breaker is depressed and then turn the UPS on.
5. To maintain optimal battery charge, leave the UPS
plugged into an AC outlet at all times.
6. To store the UPS for an extended period, cover it
and store with the battery fully charged. While in
storage, recharge the battery every three months
to ensure battery life.
7. Ensure the wall outlet and UPS are located
near the equipment being attached for proper
accessibility.
PLUG IN
SYSTEM FUNCTION BLOCK DIAGRAM
EMI
Filter
Surge
Suppressor
AVR
Charger
AC/DC
Battery
Inverter
Input Output
Normal Mode
Battery Mode


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: PR750LCD3C

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower PR750LCD3C stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd CyberPower

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Electrolux

Electrolux STA9 Handleiding

23 November 2024
Electrolux

Electrolux UMP3 Handleiding

23 November 2024
Bosch

Bosch HEZ8TK36UC Handleiding

23 November 2024
Bosch

Bosch HEZ8ZZ36UC Handleiding

23 November 2024
Bosch

Bosch HDZIT301 Handleiding

23 November 2024
Bosch

Bosch HEZBS301 Handleiding

23 November 2024
LG

LG LX-330 Handleiding

23 November 2024
Bosch

Bosch KSZ2AVU00 Handleiding

22 November 2024