CyberPower MP1021SS Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor CyberPower MP1021SS (1 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK:
Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOT ā€œdaisy chainā€ surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is less than 10 meters (30 feet) of wire between
the electrical outlet and electrical service panel.
DO NOT use for medical or life support equipment. This device features an internal
protection that will disconnect the surge protective component at the end of its
useful life, but it will maintain unprotected power to the load.
FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding:
ā€¢ Product information and certiļ¬cations
ā€¢ Product warranty
ā€¢ Connected equipment guarantee
TECHNICAL SUPPORT
Visit: CyberPowerSystems.com/support
Toll-Free: 1-877-297-6937
Hours of Operation: Monday - Friday: 7:00am - 6:00pm CST
Ā© 2022 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.
FEATURES
1. Protected LED Indicator
Illuminated when the surge protection feature is
working properly.
2. Grounded LED Indicator
Illuminated when a properly grounded AC outlet
is detected.
3. ON / OFF Reset Control Switch and Circuit Breaker
Controls power to all outlets. The switch is also a 15 A
breaker. When an overload occurs, it will automatically
switch oī˜ž. To resume operation, ensure the overload
condition is removed and reset the surge protector by
switching the unit ON.
4. USB Charging Ports*
Connect and charge up to two (2) USB devices using the
surge protected USB charging ports.
*USB outlets cannot be used as a USB hub. This device
does not transfer data.
5. Wide-Spaced Outlet
Easily plug in large chargers without interfering with the
other outlets.
TROUBLESHOOTING
If the grounded indicator does not light when you plug in the surge protector,
move the surge protector to a diī˜žerent grounded three-prong AC outlet. If it
still does not light, return the product to the retailer for assistance. If the surge
protector appears to be working properly, your outlets may not be properly
grounded and need to be repaired by a professional electrician. If the grounded
indicator turns oī˜ž after a period of use, the surge protection has been depleted.
Replace your surge protector.
If the protected indicator does not light, the surge protectorā€™s AC lines are no
longer protected from surge. The surge protector may have received a power
surge or spike beyond its speciļ¬ed limits that overloaded the protection circuitry
and rendered it inactive. The surge protector has protected your connected
equipment as designed, but it will not protect against future surges and spikes.
It should be replaced.
8-OUTLET SURGE PROTECTOR
(8 AC & 2 USB PORTS)
MP1021SS
USER MANUAL
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com
SPECIFICATIONS
Model Number: MP1021SS
Outlets:
6 Standard Outlets,
2 Transformer-Spaced Outlets,
2 USB Charge Ports
(2.4 Amps, shared)
Surge Protection: 3,000 Joules
Electrical Rating: 125 V / 15 A / 1875 W
UL Clamping Voltage:
UL1449 4th
600 V (H-N, H-G, N-G)
Maximum Peak Current: 105,000 A
3 AC Lines Protected:
H-N: 45,000 A;
H-G: 30,000 A;
N-G: 30,000 A
Response Time: Less than 1 nanosecond
USB Charger Rating: 5 V, 2.4 A Total
Circuit Breaker: Resettable 15 A
Plug Style: Right Angle Type
Power Cord Length: 6-ft. cord
i WARNING: This product can expose you to chemicals including bisphenol A (BPA)
and styrene (ABS), which is known to the State of California to cause reproductive
harm and cancer. For more information, go to www.P65Warnings.ca.gov.
CONFORMANCE APPROVALS
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined by
turning the equipment oā€ and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
ā€¢ Reorient or relocate the receiving antenna.
ā€¢ Increase the separation between the equipment and receiver.
ā€¢ Connect the equipment into an outlet on a circuit diā€erent from
that to which the receiver is connected.
ā€¢ Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modiļ¬cations not expressly approved by the
party responsible for compliance could void the userā€™s authority to
operate the equipment.
1 2
4
3
5


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: MP1021SS

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower MP1021SS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd CyberPower

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd