PRODUCT OVERVIEW
1. Pass through AC outlet
2. Network Interface Reset Button
3. Cable Guard
4. AC Input Plug
5. 3-Pin Connect
WARNINGS
ā€¢ Review the following important safety warnings to avoid bodily
injury or damage to equipment during installation or operation
of this device.
ā€¢ Read All instructions before attempting to install or operate
this device.
ā€¢ This device is intended for indoor use only. To prevent the risk
of ļ¬re or electrical shock, install in dry location free from damp
or wet environment, or potentially damp or wet environment.
ā€¢ Adhere to all acceptable operating environment limitations as
listed to prevent the risk of ļ¬re or electrical shock (See
speciļ¬cations within user manual)
ā€¢ NO user-replaceable parts within this device. To avoid bodily
injury, risk of ļ¬re or electrical shock, do not attempt to remove
cover of device.
ā€¢ Device is not designed for use with any alternate connection to
AC power than as stated within user speciļ¬cations of this
user manual.
PACKAGE CONTENTS
ā€¢ 1 x Switching Power Supply
ā€¢ 1 x 3-Pin Connector
ā€¢ 1 x User Manual
ā€¢ 3 x Cable Ties
Copyright Ā© 2020 Cyber Power Systems (USA), Inc. All rights reserved.
USER MANUAL
ONT POWER SUPPLY
CSPS12V36W
ONT POWER SUPPLY
CSPS12V36W
14
5
2
3
INTRODUCTION
Inspect CSPS12V36W for any visible damage before proceeding to
the following steps. If CSPS12V36W shows visible signs of any
damage at time of unpacking, then device should not be installed.
INSTALLATION
1. Plug 3-pin connector with attached cable into DC/Control
terminal output.
2. Using provided cable ties, secure cable to cable guard running
cable through provided holes in cable guard.
3. Plug CSPS12V36W into an AC outlet.
NOTES:
ā€¢ Network Interface Reset Button - Allows for reset of DC power
output when pushed and held for 5 seconds. This provides
reset/reboot option for Optical Terminal Network (ONT) without
having to unscrew CSPS12V36W from wall plate mount, unplug
and replug at AC outlet in order to reset DC power output.
ā€¢ Please use the CSPS12V36W in safe environment (Pass through
AC outlet working power higher than 1200W are not allowed)
A. NEGATIVE (-) / COMMONLY BLACK WIRE
B. POSITIVE (+) / COMMONLY RED WIRE
C. CONTROL (BATTERY CHARGE/COMM.ONLY)
A B C
6
CyberPowerSystems.com
Ā© 2020 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.
K01-0000854-00
FCC NOTICE (FOR USA)
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Note: The Grantee is not responsible for any changes or
modiļ¬cations not expressly approved by the party responsible for
compliance. Such modiļ¬cations could void the user's authority to
operate the equipment.
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment oī˜ž and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
ā€¢ Reorient or relocate the receiving antenna.
ā€¢ Increase the separation between the equipment and receiver.
ā€¢ Connect the equipment into an outlet on a circuit diī˜žerent from
that to which the receiver is connected.
ā€¢ Consult the dealer or an experienced radio/TV technician
for help.
To maintain compliance with FCC's RF exposure guidelines, this
equipment should be installed and operated with a minimum
distance of 20cm between the radiator and your body.
CONTACT INFORMATION
Cyber Power Systems (USA), Inc.
4241 12th Avenue East Suite 400
Shakopee, MN 55379
Toll-free: 1-877-297-6937 | CyberPowerSystems.com
SPECIFICATIONS
INPUT
Input Type
Voltage Range
Frequency
Nominal Voltage
Surge Resistance
Network Interface Reset Button
OUTPUT 1
Output Type
Output Voltage (Same as Input voltage)
Frequency (Same as Input Frequency)
Max Current Limit
Max Watt Limit
OUTPUT 2
Output Type
Output Voltage
Output Current
Continuous Power
Eī˜ciency
Voltage Control
PHYSICAL
Dimensions (in)
Weight (lb)
ENVIRONMENT
Operating Temperature
Storage Temperature
Operating Humidity
Operation Elevation
Environmental
NAME 5-15P
100 ā€“ 240 Vac
50/60 Hz
120 Vac
IEC 61000-4-5
Yes
NAME 5-15R
100 ā€“ 240 Vac
50/60 Hz
10 ā€“ 5 Amp
1200 Watt
3 position terminal (IDC)
12 Vdc
3 Amp (Max)
36 Watt (Max)
88%
5 Vdc (5mA DC Max)
5.55 x 2.69 x 2.22
0.374
-40 C ~ +40 CĀ° Ā°
-40 C ~ +45 C Ā° Ā°
5 ~ 95%
< 5,000 ft
RoHS Compliant


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: CSPS12V36W

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower CSPS12V36W stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd CyberPower

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd