YOUR ULTIMATE ALLY IN POWER
RACKBAR SURGE PROTECTORS
CPS815RMS / CPS1615RMS
USER MANUAL
Front View
Rear View
Mounting Bracket
Circuit Breaker
Front Outlets (CPS1615RMS)
Grounded LED Indicator
Protected LED Indicator
Rear Outlets
AC Power Cord
1 5
2 6
3 7
4
1
1 6 7
2 4 53
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 | CyberPowerSystems.com
Read the following before installing or operating the
RackBar Surge:
‱ ONLY use the supplied hardware to attach the
mounting brackets.
‱ The RackBar must only be plugged into a three-wire,
grounded outlet on a circuit protected by a fuse or
circuit breaker. Connection to any other type of power
outlet may result in a shock hazard.
‱ DO NOT use extension cords or adapters with
this RackBar.
‱ NEVER install a RackBar, or associated wiring or
equipment, during a lightning storm.
‱ Ensure that the power cord, plug, and socket are in
good condition.
‱ This device features an internal protection that will
disconnect the surge protective component at the end
of its useful life but will maintain power to the load —
now unprotected. If this situation is undesirable for the
application, follow the manufacturer’s instructions for
replacing the device.
‱ CAUTION! Do not install this device if there is not at
least 10 meters (30 feet) or more of wire between the
electrical outlet and the electrical service panel.
‱ CAUTION! To prevent the risk of ïŹre or electric shock,
this RackBar should be installed in a temperature and
humidity controlled indoor area free of conductive
contaminants. Do not install this RackBar where
excessive moisture or heat.
SAFETY PRECAUTIONS PRÉCAUTIONS DE SÉCURITÉ
Lisez ce qui suit avant d’installer ou d’utiliser
les RackBar Sures:
‱ Utilisez uniquement le matĂ©riel fourni pour ïŹxer les
supports de montage.
‱ La RackBar doit ĂȘtre branchĂ©e sur une prise Ă  trois ïŹls
mise à la terre sur un circuit protégé par un fusible ou
un disjoncteur. La connexion Ă  tout autre type de prise
de courant peut provoquer un choc Ă©lectrique.
‱ N’utilisez pas de rallonges ni d’adaptateurs avec
cette RackBar.
‱ N’installez jamais une RackBar ni le cñblage ou
l’équipement associĂ© pendant un orage.
‱ Assurez-vous que le cordon d’alimentation, la ïŹche
et la prise sont en bon Ă©tat.
‱ Cet appareil est dotĂ© d’une protection interne qui
déconnectera le composant de protection contre les
surtensions Ă  la ïŹn de sa vie utile, tout en maintenant
l’alimentation de la charge, dĂ©sormais non protĂ©gĂ©e.
Si cette situation n’est pas souhaitable pour
l’application, suivez les instructions du fabricant pour
remplacer le périphérique.
‱ ATTENTION! NE PAS installer cet appareil si la prise
secteur est reliĂ©e au panneau d’entrĂ©e d’électricitĂ© Ă 
une distance inférieure à 30 pieds (10 mÚtres).
‱ ATTENTION! Pour Ă©viter tout risque d’incendie ou de
choc Ă©lectrique, ce RackBar doit ĂȘtre installĂ© dans une
zone intérieure à température et humidité contrÎlées,
exempt de contaminants conducteurs. N’installez
pas ce RackBar en prĂ©sence d’humiditĂ© excessive ou
de chaleur.
Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOT “daisy chain” surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is less than 10 meters
(30 feet) of wire between the electrical outlet and
electrical service panel.
DO NOT use for medical or life support equipment. This
device features an internal protection that will disconnect
the surge protective component at the end of its useful life,
but it will maintain unprotected power to the load.
WARNING To prevent the risk of ïŹre or electric shock, this
RKBS should be installed in a temperature and humidity
controlled indoor area free of conductive contaminants.
Do not install this RackBar where excessive moisture or
heat is present.
TO REDUCE THE RISK OF ELECTRIC SHOCK:
Thank you for purchasing a CyberPower product. This product is designed to provide unsurpassed power protection,
operation, and performance during the lifetime of the product. Please take a few minutes to register your product at:
www.CyberPowerSystems.com/registration.
Registration certiïŹes your product’s warranty, conïŹrms your ownership in the event of a product loss or theft, and entitles
you to free technical support. Register your product now to receive the beneïŹts of CyberPower ownership.
PRODUCT REGISTRATION
INSTALLATION
ELECTRICAL INSTALLATION
Horizontal Installation
1. Mounting Bracket Installation - Install the screws
(M4 X 4) in holes diagonal from each other.
Vertical Installation
1. Mounting Bracket Installation - Install the screws
(M4 X 4) in holes diagonal from each other.
2. RackBar Mounting - Install the RackBar using the
fasteners that are compatible with the rack.
1. Receptacle evaluation
Ensure that the plug type of your RackBar unit
(e.g. NEMA 5-15P) matches the wall receptacle type
that you are using.
RackBar must be plugged into a three-wire,
grounded wall receptacle only. The wall receptacle
must also be connected to an appropriate branch
circuit/main with fuse or circuit breaker protection.
Connection to any other type of wall receptacle may
result in a shock hazard.
2. Plug the RackBar into the wall receptacle.
3. Attach equipment
Before attaching equipment, it is important to
calculate the total load that you will be placing on the
RackBar. It is extremely important not to exceed the
RackBar’s maximum current load (as outlined in the
SpeciïŹcations section). In order to determine your total
load, simply add up the amperage of your devices and
ensure that it does not exceed the unit’s capacity.
4. Verify protection
Verify that both the Grounded and Protected LEDs
are illuminated. This means that the RackBar is
properly grounded and is protecting the equipment
from surges.
Grounded LED (Green) Protected LED (Green)
INTRODUCTION
Unpacking
Inspect the RackBar surge upon receipt. The box should
contain the following:
(a) RackBar Surge Unit
(b) Mounting Brackets: (1) Horizontal set, (1) Vertical set
(c) Bracket Mounting Screws (4) Flat Head M4
(d) User Manual
2. Mounting - Install the RackBar using the fasteners that
are compatible with the rack.


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: CPS815RMS

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower CPS815RMS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd CyberPower

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Electrolux

Electrolux STA9 Handleiding

23 November 2024
Electrolux

Electrolux UMP3 Handleiding

23 November 2024
Bosch

Bosch HEZ8TK36UC Handleiding

23 November 2024
Bosch

Bosch HEZ8ZZ36UC Handleiding

23 November 2024
Bosch

Bosch HDZIT301 Handleiding

23 November 2024
Bosch

Bosch HEZBS301 Handleiding

23 November 2024
LG

LG LX-330 Handleiding

23 November 2024
Bosch

Bosch KSZ2AVU00 Handleiding

22 November 2024