CyberPower BM240V63ART3U Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor CyberPower BM240V63ART3U (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
User’s Manual
EXTENDED BATTERY MODULE (EBM)
BM240V63ART3U
Cyber Power Systems Inc.
www.cyberpower.com
K01-0000708- 00
Copyright © 2018 Cyber Power Systems, Inc.
HARDWARE INSTALLATION
2
HARDWARE INSTALLATION
These versatile UPS systems can be mounted in a rackmount or vertical
tower orientation. This versatility is especially important to growing
organizations with changing needs that value having the option to
position a UPS on a floor or in a rackmount system. Please follow the
instructions below for the respective mounting methods.
SAFETY PRECAUTIONS
CAUTION! To prevent the risk of fire or electric shock, only use the
supplied hardware to attach the mounting brackets.
RACKMOUNT INSTALLATION
Step 1 Remove the dust covers :
Remove the dust covers * pcs from the screw holes. 10
Step 2: Rackmount e s & hanging brackets installation ar
Attach two rackmount ears to the UPS using the provided M5X7L*8pcs
screws and tighten two hanging brackets with the M5X6L*6pcs screws.
Step 3: Rackmount rail Installation
The rails adjust to mount in 48-cm (19-inch) panel racks from 52 to
91.5cm (20.5 to 36 inches) deep. Select the proper holes in the rack for
positioning the EBM in the rack. The EBM takes up position 1 through 9.
Position the guide screws on the rails into the rear rack square holes to
temporarily support the rails in place. Tighten the front rail screws on the
rack.
Copyright © 2018 Cyber Power Systems, Inc.
HARDWARE INSTALLATION
3
Step 4: Adjust rackmount rails to fit your rack
Adjust the rail depth to match your rack depth. Attach the rackmount rail
to your rack with two screws and two plastic washers at the front of the
rack. (Located in position 4 & position 8) Tighten the M5X6L screws on
the front bracket. Secure the rail to the rear of the rack with two M5X6L
screws and two plastic washers.
Step 5: Place and secure the EBM on the rails
Slide the hanging brackets on the EBM into the rails mounted in the rack
with the front of the unit facing toward you. Secure the EBM to your rack
with four M5X12L*4pcs screws at the front of the rack. (Located in
position 5 & position 7)
How to Slide EBM from rail out
The Battery pack will be secured by a safety locking mechanism midway
of pulling it out of the rack. Use both hands to hold the Battery pack and
press the safety locking tab to pull the Battery pack out.


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: BM240V63ART3U
Kleur van het product: Zwart
Gewicht: 78000 g
Breedte: 433 mm
Diepte: 660 mm
Hoogte: 132 mm
Gewicht verpakking: 95000 g
Breedte verpakking: 600 mm
Diepte verpakking: 900 mm
Hoogte verpakking: 375 mm
Materiaal behuizing: Metaal
Vormfactor: Rackmontage/toren
Accu/Batterij voltage: 12 V
Ondersteund aantal accu's/batterijen: 20
Certificering: RCM
Batterij capaciteit: 9 Ah
Aantal: 1
Temperatuur bij opslag: -15 - 45 °C
Luchtvochtigheid bij opslag: 0 - 95 procent
Rack-montage: Ja
Compatibele producten: RT33020KE, RT33025KE, RT33030KE
Rackcapaciteit: 3U
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 90 procent
Batterijtechnologie: Sealed Lead Acid (VRLA)
Hot-swap batterij: Ja