Quick Start Guide 931479A
1.0 Out-of-Box and Prior to Final Installation
1.1. Verify that you have received all of the parts listed on the Installation Quick
Reference placemat.
1.2. Download the current manual, otherwise known as an Operation Guide,
which is available in the Downloads tab at the following webpage:
http://www.cyberdata.net/voip/011461/
Note You can also navigate to the Downloads tab by going to
www.CyberData.net and following the steps that are indicated by
the following figures:
2.0 Select Power Source
PoE Switch PoE Injector
Set PoE power type to Class 0 = 15.4W CAT6 cable recommended—
for longer distances
Be sure you are using a non-PoE switch or port
Make sure port is not in trunk mode
Set port to full duplex/ 100Mbps
1
3 4
2
Part Number: 011461
SIP Vandal Resistant Keypad Phone
SIP Vandal Resistant Keypad Phone
Quick Start Guide
The IP Endpoint Company
Quick Start Guide 931479A
3.0 Power Test
3.1. Plug in the CyberData device and monitor the LED activity above the
ethernet port on the board. See the following figure:
3.2. The amber 100 Mb Link LED blinks off once during the boot up process
when the device begins DHCP addressing and autoprovisioning attempts,
and then comes on again and remains constant (solid amber). The green
Link/Activity LED may be blinking depending on the network activity.
Note The default DHCP addressing timeout is 60 seconds. The device will attempt
DHCP addressing 12 times with a 3 second delay between tries and eventually
fall back to the programmed static IP address (by default 10.10.10.10) if DHCP
addressing fails. The DHCP Timeout is configurable in the device's Network
settings.
3.3. When the device has completed the initialization process, press and hold
the RESET switch (SW1 button) for 3 seconds to announce the IP address.
This concludes the power test. Go to Section 4.0, "Connecting to a Network
in a Test Environment".
100 Mb Link LED
Link/Activity J1
Quick Start Guide 931479A
4.0 Connecting to a Network in a Test Environment
Note The following connections are usually needed for this procedure:
• Computer
• PoE switch or injector
• CyberData device
4.1. In a test environment, use a computer that is connected to the same switch
as a single CyberData device. Note the subnet of the test computer.
4.2. Use the CyberData Discovery Utility program to locate the device on the
network. You can download the Discovery Utility program from the following
link:
http://www.cyberdata.net/assets/common/discovery.zip
4.3. Wait for initialization to complete before using the Discovery Utility program
to scan for a device. The device will show the current IP address, MAC
address, and serial number.
4.4. Select the device.
4.5. Click Launch Browser. If the IP address is in a reachable subnet from the
computer that you are using to access the device, the Discovery Utility
program should be able to launch a browser window pointing to the device’s
IP address.
4.6. Log on to the web interface by using the default username (admin) and
password (admin) to configure the device.
4.7. Perform an audio test by pressing the Test Audio button that is located at
the bottom of the Device Configuration page. If the audio test message is
clearly audible, then your CyberData device is functioning properly.
4.8. The device is now ready to be set for your desired network configuration.
You may search the Compatible IP-PBX Servers index for available
sample VoIP phone system configurations and set up guides at the following
website address:
http://www.cyberdata.net/connecting-to-ip-pbx-servers/


Product specificaties

Merk: CyberData Systems
Categorie: Telefoon
Model: 011461
Kleur van het product: Roestvrijstaal
Gewicht: 5500 g
Breedte: 237 mm
Diepte: 153 mm
Hoogte: 391 mm
Gewicht verpakking: 5900 g
Bluetooth: Nee
Touchscreen: Nee
Stemcodecs: G.711alaw, G.711ulaw, G.722
Ethernet LAN: Ja
Snelkiezen: Ja
Certificering: CE; EMC Directive - Class A EN 55032 & EN 55024, LV Safety Directive- EN 60950-1, RoHS Compliant, FCC; Part 15 Class A, Industry Canada; ICES-3 Class A
Video call: Nee
Duurzaamheidscertificaten: CE
Ruisonderdrukking: Ja
Interfacetype Ethernet LAN: Fast Ethernet
Netwerkstandaard: IEEE 802.3, IEEE 802.3af, IEEE 802.3u
Temperatuur bij opslag: -40 - 70 °C
Camera voorzijde: Nee
Naleving van duurzaamheid: Ja
Aantal handvatten opgenomen: 1 stuk(s)
Power over Ethernet (PoE): Ja
Handset type: Handset met snoer
Capaciteit telefoonboek: - entries
Montage: Muur
VoIP protocollen: SIP RFC 3261
Lijn-kwantiteit: - regels
Wifi: Nee
Bedrijfstemperatuur (T-T): -40 - 60 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
Type product: IP Phone
Huls materiaal: Aluminium
Compatibel met gehoorapparaten: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met CyberData Systems 011461 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Telefoon CyberData Systems

Handleiding Telefoon

Nieuwste handleidingen voor Telefoon

Yealink

Yealink MP56 E2 Handleiding

24 September 2024
Yealink

Yealink MP54 E2 Handleiding

23 September 2024
Yealink

Yealink MP58-WH E2 Handleiding

23 September 2024
Yealink

Yealink MP52 E2 Handleiding

23 September 2024
VXi

VXi D200 Dialpad Handleiding

11 September 2024
Lewitt

Lewitt LCT 240 Handleiding

6 September 2024
Valcom

Valcom VIP-430 Handleiding

5 September 2024
Valcom

Valcom VIP-431 Handleiding

5 September 2024
Valcom

Valcom V-5330210 Handleiding

5 September 2024
Valcom

Valcom V-5330110 Handleiding

5 September 2024