INET-IOEX-IRCOM
inNET EX® Control Module
Installation Guide
Description
The INET-IOEX-IRCOM provides an IR and RS-232
control interface for video displays, AV components,
small appliances, and other equipment. It includes two
discrete IR ports and one bidirectional RS-232 port. It
communicates with a Crestron® control system via the
inNET EX® wireless network, enabling control and
monitoring of the remote equipment without having to
run wires through walls and ceilings.
Installation
The INET-IOEX-IRCOM can be mounted onto any at
surface using three screws (not included). For best
results, position the device to avoid interference from
nearby RF sources, obstructions, and metal surfaces.
Additional Resources
Visit the product page on the
Crestron website
(www.crestron.com) or scan the QR
code to the right for additional
information and the latest rmware
updates.
CAUTION: Observe the + and - markings on the
power pack leads. Connect the + to the 5 terminal
and the - to the G terminal on the INET-IOEX-IRCOM.
NOTE: The INET-IOEX-IRCOM can also be powered
via USB. For example, refer to the TTL-232R-5V-WE
at www.mouser.com.
Hardware Hookup
Make the necessary connections as called out in the
following illustration.
When making connections to the INET-IOEX-IRCOM,
use Crestron power supplies for Crestron equipment.
G/TX/RX:
To Any
RS-232 Device
S/G (1 - 2):
To IR Devices
PWR:
From DC
Power Pack
Wireless Communications
The INET-IOEX-IRCOM connects to the Crestron
network via the inNET EX communications protocol.
Use the procedures outlined below to join or leave an
inNET EX network and to verify communications
between the device and the control system.
Joining an inNET EX Network
Before the INET-IOEX-IRCOM can be used, it must rst
join an inNET EX network by being acquired by an
inNET EX gateway.
NOTE: A device can be acquired by only one
gateway.
1. Put the inNET EX gateway into Acquire mode
from the unit itself or from Crestron Toolbox™, as
described in its manual at
www.crestron.com/manuals.
NOTE: In an environment where multiple
gateways are installed, only one gateway should
be in Acquire mode at any time.
2. Place the device into Acquire mode.
a. Tap the button three times, and then SETUP
press and hold it down
(tap-tap-tap-press+hold) until the LED on the
device blinks once (this can take up to 10
seconds).
b. Release the button to start the acquire process.
The LED blinks slowly to show that the device
is actively scanning the inNET EX network.
• The top LED turns on for 5 seconds to show
that the device has been successfully
acquired by the infiNET EX network.
• The LED blinks fast to indicate that the
device was not successfully acquired by the
infiNET EX network. Tap the button SETUP
to acknowledge failure to acquire the
infiNET EX network. Ensure the gateway is
in Acquire mode and within range before
attempting the acquire process again.
3. Once all devices have been acquired, take the
gateway out of Acquire mode. Refer to the
gateway’s operations guide for details.
Leaving an inNET EX Network
To leave an inNET EX network, put the
INET-IOEX-IRCOM into Acquire mode, as described in
“Joining an inNET EX Network” above, when no
gateway is in Acquire mode.
Crestron Electronics, Inc. Installation Guide - DOC. 7476E
15 Volvo Drive Rockleigh, NJ 07647 (2035851)
Tel: 888.CRESTRON 04.15
Fax: 201.767.7576 Specications subject to
www.crestron.com change without notice.
As of the date of manufacture, the INET-IOEX-IRCOM has
been tested and found to comply with specications for CE
marking.
Federal Communications Commission (FCC) Compliance
Statement
This device complies with part 15 of the FCC Rules.
Operation is subject to the following conditions: (1) This
device may not cause harmful interference and (2) this device
must accept any interference received, including interference
that may cause undesired operation.
CAUTION: Changes or modications not expressly
approved by the manufacturer responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a residential installation. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and
receiver
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV
technician for help
Industry Canada (IC) Compliance Statement
This device complies with Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference and (2)
this device must accept any interference, including
interference that may cause undesired operation of the
device.
Under Industry Canada regulations, this radio transmitter may
only operate using an antenna of a type and maximum (or
lesser) gain approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the
antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more
than that necessary for successful communication.
Industrie Canada (IC) Déclaration de conformité
Le présent appareil est conforme aux CNR d’Industrie
Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes: (1)
l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur
de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le
fonctionnement.
Conformément à la réglementation d’Industrie Canada, le
présent émetteur radio peut fonctionner avec une antenne
d’un type et d’un gain maximal (ou inférieur) approuvé pour
l’émetteur par Industrie Canada. Dans le but de réduire les
risques de brouillage radioélectrique à l’intention des autres
utilisateurs, il faut choisir le type d’antenne et son gain de
sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.)
ne dépasse pas l’intensité nécessaire à l’établissement d’une
communication satisfaisante.
To satisfy RF exposure requirements, this device and its
antenna must operate with a separation distance of at least
20 centimeters from all persons and must not be colocated in
conjunction with any other antenna or transmitter.
The product warranty can be found at
www.crestron.com/warranty.
The specic patents that cover Crestron products are listed at
patents.crestron.com.
Crestron, the Crestron logo, Crestron Toolbox, and inNET
EX are either trademarks or registered trademarks of Crestron
Electronics, Inc. in the United States and/or other countries.
Other trademarks, registered trademarks, and trade names
may be used in this document to refer to either the entities
claiming the marks and names or their products. Crestron
disclaims any proprietary interest in the marks and names of
others. Crestron is not responsible for errors in typography or
photography.
This document was written by the Technical Publications
department at Crestron.
©2015 Crestron Electronics, Inc.
Verifying Communications Status
To check the communications status of the device, tap
the button three times, and then press and hold SETUP
it down (tap-tap-tap-press+hold) for up to 2 seconds.
The LED blinks to indicate the communications status.
Refer to the following table for details.
LED COMMUNICATIONS STATUS
Turns on for 5 seconds Device is communicating with the control system.
Blinks three times Device is communicating with the gateway but the
gateway is not communicating with the control system.
Blinks twice Device was previously joined to the network but is not
communicating with the gateway.
Blinks once Device is not joined to the network.


Product specificaties

Merk: Crestron
Categorie: Controller
Model: INET-IOEX-IRCOM

Heb je hulp nodig?

Als je hulp nodig hebt met Crestron INET-IOEX-IRCOM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Controller Crestron

Handleiding Controller

Nieuwste handleidingen voor Controller