Crestron CLW-DIMEX-P Handleiding
Lees hieronder de đ handleiding in het Nederlandse voor Crestron CLW-DIMEX-P (2 pagina's) in de categorie Dimmer. Deze handleiding was nuttig voor 2 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2

CLW-DIMEX-P
CameoÂź Wireless In-Wall Dimmer, 120 V
Operations & Installation Guide
Description
The CrestronÂź CLW-DIMEX-P is a CameoÂź in-wall dimmer that features îeld-replaceable,
engravable buttons. Along with the entire line of new Cameo products, it can be
conîgured with various button layouts and designer colors, making the CLW-DIMEX-P
more versatile and affordable than previous generations of in-wall dimmers. Its streamlined
design matches the entire line of Cameo dimmers, switches, and keypads, making it a
great addition to new or retroît installations. In addition to its attractive look and feel,
inîNET EXÂź communication technology brings proven reliability to the CLW-DIMEX-P.
CLW-DIMEX-P Speciîcations
Additional Resources
Visit the product page on the Crestron website (www.crestron.com) or
scan the QR code to the right for additional information and the latest
îrmware updates.
WARNING: To avoid îre, shock, or death, turn off power at circuit breaker or fuse and
test that power is off before wiring!
WARNING: New installations should be checked for short circuits prior to installing a
CLW-DIMEX-P dimmer. With power off, close the circuit and restore power. If the lights
do not work or a breaker trips, check and correct the wiring or îxture (if necessary).
Install the dimmer only when the short is no longer present. The warranty is void if the
dimmer is installed and operated with a shorted load.
CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO
OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE, A
MOTOR-OPERATED APPLIANCE, A FLUORESCENT LIGHTING FIXTURE, OR A
TRANSFORMER-SUPPLIED APPLIANCE.
ATTENTION : GRADATEURS COMMANDANT UN BALLAST-AFIN DE RĂDUIRE LE
RISQUE DE SURCHAUFFE ET LA POSSIBILITĂ DâENDOMMAGEMENT Ă DâAUTRES
MATĂRIELS, NE PAS INSTALLER POUR COMMANDER UNE PRISE, UN APPAREIL
DâĂCLAIRAGE FLUORESCENT, UN APPAREIL OPĂRĂ DE MOTEUR OU UN APPAREIL
ALIMENTĂ PAR UN TRANSFORMATEUR.
NOTES: Observe the following points.
âą Codes: This product should be installed and used in accordance with appropriate
electrical codes and regulations.
âą Installation: This product should be installed by a qualiîed electrician.
âą Wiring: Use copper wire only. For supply connections, use wires rated for at least
75°C (167°F).
âą Lamp Type: For use with permanently installed incandescent, magnetic low voltage,
tungsten-halogen, or dimmable CFL only.
⹠Temperature: For use where temperatures are between 32° to 104°F (0° to 40°C).
âą Electrical Boxes: Devices mount in standard electrical boxes. For easy installation,
use 3 1/2 in (89 mm) deep electrical boxes. Several devices can be installed in one
electrical box (multigang). This requires derating of the dimming device. For a
smooth appearance, one-piece multigang faceplates (not supplied) can be installed.
âą Switches: Mechanical 3- or 4-way switches do not work with CLW-DIMEX-P
dimmers.
âą Spacing: If mounting one device above another, leave at least 4 1/2 in (115 mm)
vertical space between them.
Installation
NOTE: Before using the CLW-DIMEX-P, ensure the device is using the latest îrmware.
Check for the latest îrmware for the CLW-DIMEX-P at www.crestron.com/îrmware.
Firmware is loaded onto the device using Crestron Toolboxâą.
NOTE: The device may be warm to the touch during operation. This is normal.
Multigang Installations
In multigang installations, several devices are grouped horizontally in one electrical box.
For a smooth appearance, one-piece multigang faceplates (not supplied) can be installed.
NOTE : When installing into a multigang box, do not fully tighten devices to the box until
the faceplate has been aligned.
The load capacity for each device in the electrical box must be derated. Refer to the
following diagrams for derating information. The VA ratings are for input power to the
transformer. If you do not know the input power requirement of the transformer, use the
bulbâs wattage rating to determine proper rating.
Derating Information for CLW-DIMEX-P Dimmers
750 VA 600 VA 600 VA 600 VA 600 VA400 VA
The following describes the installation of a CLW-DIMEX-P dimmer.
1. Turn power off at the circuit breaker.
2. Wire the device as shown in the following diagrams.
NOTE : The dimmer can operate with or without a direct connection to the neutral.
NOTE: Switch mode requires a dedicated neutral.
Black
White
NEU DIM
HOT
REM
Line
120 V~ Load
White
Black
To One or More
CLW-SLVU-P1
(Optional)
3. Push all power wires back into the electrical box and fasten the device to the electrical
box with the provided screws.
4. Attach the decorative faceplate.
5. Ensure all buttons, including the program button, actuate without sticking.
NOTE : To operate the device in Switch mode, follow the instructions in "Switching
Between Dim Mode and Switch Mode" before restoring power.
6. Restore power at the circuit breaker.
NOTE : For optimal performance, the neutral should be connected. If the neutral is
not connected, the minimum required load is 50 watts.
Changing the Button Assemblies
The button assembly can be removed and replaced with other button assemblies.
1. Remove the button assembly by squeezing the sides of the bezel near the bezel
snaps.
NOTE: When the button assembly is removed, power to the unit and load is
removed automatically.
2. Remove the button from the front of the button assembly.
3. Insert the new buttons through the front of the bezel and snap them into place.
Ensure that the LED strip is on the left side.
4. Attach button assembly to the device. Ensure that the LED strip is on the left side.
5. Once power has been restored, press and hold the program button. After 5 seconds,
the LEDs associated with the old button layout begin to flash. Continue to hold the
button and proceed to step 6.
Squeeze at the arrow
points and pull to
remove the button
assembly.
Gently spread the
frame apart to remove
the buttons.
Gently spread the
frame apart to insert
the buttons.
Operation
Basic Operation
The operations described in this guide assume the CLW-DIMEX-P is operating in Local
mode (without the use of a control system). The device can also operate in Remote mode,
in which button behavior is dictated entirely by the control system program. The
CLW-DIMEX-P is shipped with a rocker switch already installed. In this conîguration, the
unit functions as described below.
The LEDs indicate the load
level. When all loads are
off, the top LED remains
dimly lit to act as a night
light.
In Switch mode, the top
LED indicates the on or off
status only. All other LEDs
are off.
Press to turn on the
load. Press and hold
to raise the light level.
Press to turn off the
load. Press and hold
to lower the light level.
1. For details, refer to the CLW-SLVU-P Installation Guide (Doc. 7364) at www.crestron.com/manuals.
* Derating applies for multigang installations. Refer to âMultigang Installationsâ for more information.
Switching Between Dim Mode and Switch Mode
The CLW-DIMEX-P is capable of operating in Switch mode. Toggling between Dim and
Switch mode is useful if the load is not dimmable or if it is preferred to not dim the load.
1. Open the air-gap switch as described in âDisconnecting the Power.â
2. While power is off, press and hold the top and bottom button caps (regardless of
button conîguration) simultaneously while closing the air-gap switch.
3. After 5 seconds, the top LED blinks 3 times to indicate Dim mode or 5 times to
indicate Switch mode.
4. To commit the new setting, release the buttons within the next 5 seconds.
6. While holding the program button, press all of the buttons in the new layout. The
LED next to the pressed button lights.
NOTE: If the rocker switch is installed, press the top and bottom of the rocker.
7. After all of the buttons have been pressed, release the program button to save the
settings.
NOTE: Changing the button conîguration alters the deviceâs behavior. Refer to
the "Default Button Functions" for details.
YesNo
Do not insert the wires behind the screw head.
Insert the wires into the wire entry holes.
Step 5:
Press and hold
the program
button.
Step 7:
Release the
program button
to save the
settings.
Step 6:
Tap each of the
installed buttons
on the device.
âą Low Voltage Applications: Use with core and coil (magnetic) low voltage transformers
only. Do not use any solid-state electronic low voltage transformers. Operation of a
low voltage circuit with all lamps inoperative or removed may result in current îow in
excess of normal levels. To avoid transformer overheating and premature transformer
failure, Crestron recommends the following:
> Do not operate low voltage circuits without operative lamps in place.
> Replace burned-out lamps as quickly as possible.
> Use transformers that incorporate thermal protection or fuse transformer primary
windings to prevent transformer failure due to overcurrent.
SPECIFICATION
DETAILS
Load Ratings
Incandescent or
Tungsten Halogen
750 watts*
Magnetic Low Voltage 750 VA/750 watts*
Minimum Load 25 watts (with dedicated neutral connected);
50 watts (no dedicated neutral)
Power Requirements 120 Vac, 60 Hz, line power
Environmental
Temperature 32° to 104°F (0° to 40°C)
Humidity 10% to 90% RH (non-condensing)
Enclosure 1-gang mountable in a 3 1/2 inch deep electrical box;
Requires decorator style faceplate (not included)

Disconnecting the Power
Power to the dimmer and load can be disconnected by pushing on the air-gap switch.
Push here to open the
air-gap.
Air-Gap Switch in the
Open Position
NOTE: If the dimmer remains powered after the air-gap is opened, the HOT and DIM
terminals have been connected in reverse. Turn off power at the circuit breaker or fuse
and adjust the connections.
NOTE: Power to the load is automatically disconnected when the button assembly is
removed. For instructions on removing the button assembly, refer to âChanging the
Button Assemblies.â
Setting Preset Levels
The CLW-DIMEX-P can recall and store up to three presets depending on the installed
button conîguration.
1. Adjust the light level to the desired level.
2. Enter Programming mode by quickly tapping the program button as shown below.
The LEDs of buttons that are capable of storing a preset will îash.
NOTE: Programming mode is disabled when the load is off.
3. Press and hold the desired preset button until the LED blinks (approximately two
seconds). Release the button to store the new level.
If a button is not pressed, the device exits Programming mode after approximately
îve seconds.
NOTE: A delayed off can be added via control system programming.
Preset 1
Single Button Press and Hold (Hold for More than 1/2 Second)
Single Button Press
Double Button Press (Press Twice within 1/2 Second)
Off Off
Preset 1
Full On
Full Off
Raise
Lower
Raise Raise
Raise
Raise Raise
Lower Lower Lower Lower Lower
Full On Full On
Full On
Full On
Full On
Full On
Full On
Full On
Full Off
Full Off
Full Off
Preset 1
Preset 1
Preset 1
Preset 1
Preset 2
Off
Raise
Raise
Lower Lower
Preset 1
Toggle
Preset 1
Toggle
Off
Default Button Functions
The îgures below illustrate the default functions available for each physical button
conîguration and tap or hold actuation sequence.
Troubleshooting
The following table provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
CLW-DIMEX-P Troubleshooting
Master and Slave Operation
For more information on master and slave operation, refer to the CLW-SLVU-P Installation
Guide (Doc. 7364).
Preset 1
Preset 2
Preset 3
Off
Step 3:
Hold the button to
store a new level.
Step 2:
Quickly tap the
program button.
LEDs îash to indicate
the buttons that can
be programmed.
This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
CAUTION: Changes or modiîcations not expressly approved by the manufacturer responsible for
compliance could void the userâs authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more if the
following measures:
Wireless Communications
The device connects to the Crestron network via the inîNET EX communications protocol.
Use the procedures outlined below to join or leave an inîNET EX network and to verify
communications between the device and the control system.
Joining an inîNET EX Network
Before a device can be used in a lighting system, it must îrst join an inîNET EX network by
being acquired by an inîNET EX gateway.
NOTE: A device can be acquired by only one gateway.
1. Put the inîNET EX gateway into Acquire mode from the unit itself or from Crestron
Toolbox, as described in its manual at www.crestron.com/manuals.
NOTE: In an environment where multiple gateways are installed, only one gateway
should be in Acquire mode at any time.
2. Place the device into Acquire mode.
a. Tap the top button three times, and then press and hold it down
(tap-tap-tap-press+hold) until the top LEDs on the device îash once (this can take
up to 10 seconds).
b. Release the button to start the acquire process. The top LED blinks slowly to show
that the device is actively scanning the inîNET EX network.
âą The top two LEDs turn on for 5 seconds to show that the device has been
successfully acquired to the infiNET EX network.
âą The top LED blinks fast to indicate that the device was not successfully acquired
by the infiNET EX network. Tap the setup button to acknowledge failure to
acquire the infiNET EX network. Ensure the gateway is in Acquire mode and
within range before attempting the acquire process again.
3. Once all devices have been acquired, take the gateway out of Acquire mode. Refer to
the gatewayâs manual for details.
Leaving an inîNET EX Network
To leave an inîNET EX network, put the device into Acquire mode, as described in âJoining
an inîNET EX Networkâ above, when no gateway is in Acquire mode.
Verifying Communications Status
To check the communications status of the device, tap the setup button three times and
then press and hold it down (tap-tap-tap-press+hold) for up to 2 seconds. The LED blinks to
indicate the communications status. Refer to the following table for details.
Crestron Electronics, Inc. Operations & Installation Guide - DOC. 6820F
15 Volvo Drive Rockleigh, NJ 07647 (2024291)
Tel: 888.CRESTRON 03.15
Fax: 201.767.7576 Speciîcations subject to
www.crestron.com change without notice.
âą Reorient or relocate the receiving antenna
âą Increase the separation between the equipment and receiver
âą Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
Industry Canada (IC) Compliance Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and
maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio
interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Industrie Canada (IC) Déclaration de conformité
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioĂ©lectrique subi, mĂȘme si le
brouillage est susceptible d'en compromettre le fonctionnement.
The product warranty can be found at www.crestron.com/warranty.
The speciîc patents that cover Crestron products are listed at patents.crestron.com.
Crestron, the Crestron logo, Cameo, Crestron Toolbox, and inîNET EX are either trademarks or
registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. UL and
the UL logo are either trademarks or registered trademarks of Underwriters Laboratories, Inc. in the
United States and/or other countries. Other trademarks, registered trademarks, and trade names may be
used in this document to refer to either the entities claiming the marks and names or their products.
Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible
for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2015 Crestron Electronics, Inc.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une
antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans
le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir
le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse
pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
Le présent émetteur radio , IC: 5683C-CWD6790, a été approuvé par Industrie Canada pour fonctionner
avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise
pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur
au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
⹠Type d'antenne: Inversé-F, Gain admissible maximal: 2.66 dBi, Impédance: 50 Ohms
To satisfy RF exposure requirements, this device and its antenna must operate with a separation distance
of at least 20 centimeters from all persons and must not be colocated or operating in conjunction with any
other antenna or transmitter.
LED COMMUNICATIONS STATUS
Turns on for 5 seconds The device is communicating with the control system.
Blinks three times The device is communicating with the gateway, but the
gateway is not communicating with the control system.
Blinks twice The device was previously joined to the network but is
not communicating with the gateway.
Blinks once The device is not joined to the network.
TROUBLE
PROBABLE CAUSE(S)
COREECTIVE ACTION
The dimmer does not
function.
The dimmer is not
receiving line power.
Verify that the power
connections are correct
and that the circuit
breaker is closed.
The load is not
operational (e.g., lamps
are burned out).
Verify that the load is
operational and that the
air-gap switch is closed.
The device is in Remote
mode.
Check the SIMPL program
to verify the operating
mode.
The dimmer does not
dim.
The device is in Switch
mode.
Remove power from the
device. Reapply power
and press and hold the
top and bottom buttons
for 5 seconds. If the LED
blinks 3 times, the device
is in Dim mode; if it blinks
5 times, it is in Switch
mode.
The dimmer remains
powered and air-gap
switch is opened.
The HOT and DIM
terminals are wired in
reverse.
Turn off power at the
circuit breaker or fuse and
adjust the connections.
The dimmer cycles off
occasionally when near
full brightness.
The load connected is
less than 25 watts.
Increase the load on the
circuit to at least 25 watts.
A neutral wire is required
for loads less than 50
watts.
The load connected is
less than 50 watts.
Connect the neutral to the
dimmer.
Product specificaties
Merk: | Crestron |
Categorie: | Dimmer |
Model: | CLW-DIMEX-P |
Breedte: | 44 mm |
Diepte: | 44 mm |
Hoogte: | 105 mm |
Soort: | Dimmer |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 10 - 90 procent |
RF-zendfrequentie: | 2400 MHz |
Heb je hulp nodig?
Als je hulp nodig hebt met Crestron CLW-DIMEX-P stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Dimmer Crestron

1 April 2025

11 Maart 2025
Handleiding Dimmer
- Dimmer ABB
- Dimmer Arendo
- Dimmer BeamZ
- Dimmer Berker
- Dimmer DIO
- Dimmer Elro
- Dimmer Eminent
- Dimmer GAO
- Dimmer GE
- Dimmer Gira
- Dimmer Grasslin
- Dimmer Hager
- Dimmer Handson
- Dimmer InterBar
- Dimmer KlikaanKlikuit
- Dimmer Mercury
- Dimmer Paladin
- Dimmer Peha
- Dimmer Schneider Electric
- Dimmer Sonoro
- Dimmer Steinel
- Dimmer TP Link
- Dimmer Tronic
- Dimmer Trust
- Dimmer VAMA
- Dimmer Velbus
- Dimmer Velleman
- Dimmer Jung
- Dimmer Cotech
- Dimmer Eurolite
- Dimmer Merten
- Dimmer Chacon
- Dimmer American DJ
- Dimmer Chauvet
- Dimmer Fibaro
- Dimmer Eltako
- Dimmer Homematic IP
- Dimmer AMX
- Dimmer Adastra
- Dimmer Tradim
- Dimmer Vimar
- Dimmer Intertechno
- Dimmer EtiamPro
- Dimmer Ltech
- Dimmer Ehmann
- Dimmer Bearware
Nieuwste handleidingen voor Dimmer

2 December 2024

1 December 2024

1 December 2024

1 December 2024

1 December 2024

1 December 2024

1 December 2024

1 December 2024

1 December 2024

1 December 2024