Casablanca Isotope 59023 Handleiding

Casablanca Ventilator Isotope 59023

Lees hieronder de 📖 handleiding in het Nederlandse voor Casablanca Isotope 59023 (16 pagina's) in de categorie Ventilator. Deze handleiding was nuttig voor 68 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Isotope ®
1
42900-01 • 07/10/13 • © Casablanca Fan Company
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and
proper installation. Therefore, before attempting to install and operate your Casablanca fan, read this Owner’s Manual
completely and carefully. Retain this manual and other included documentation for future reference.
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off at the circuit breaker or
fuse box before attempting any installation procedure.
Isotope ® Owner’s Manual
READ AND SAVE THESE INSTRUCTIONS!
CONTENTS
INTRODUCTION 3 ...........................................................................................
MOUNTING RECOMMENDATIONS .......................................................................... 4
FAN INSTALLATION ........................................................................................5
MOTOR HOUSING INSTALLATION ...........................................................................6
BLADE INSTALLATION ......................................................................................10
LIGHT BULB AND GLASS INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
WALL CONTROL INSTALLATION ............................................................................12
WALL CONTROL OPERATION 13 ...............................................................................
TROUBLESHOOTING TIPS ..................................................................................15
CARE RECOMMENDATIONS ................................................................................16
2
42900-01 • 07/10/13 • © Casablanca Fan Company
PLEASE INSPECT ALL PACKAGING PRIOR TO DISCARDING!
Your Casablanca fan was crafted with pride and care and inspected thoroughly prior to shipment.
Before you begin to assemble and install your Casablanca fan, remove all parts from the carton and
check them against the Parts Guide in this manual.
Make sure all parts are included in the box using the
Parts Guide on the following pages.
If there are missing or broken parts:
Call 1-888-227-2178 Monday through Friday, 7 a.m.
to 4 p.m. Your request will be handled immediately.
Replacement parts will be sent to you via Federal
Express.
Proper Parts Handling
Do not remove light bulbs from their packaging until you
are ready to install them.
Before discarding packaging materials, be certain that all
parts have been removed.
Use a clean, dry paintbrush to remove small Styrofoam
pieces that may remain after unpacking.
Do not brush Styrofoam into wiring cavities.
The blades in each pack are matched for equal weight to
assure smooth fan operation. If more than one fan is
being installed, do not mix blades from different cartons.
When cleaning, painting, or working near your fan, be
cautious of the fan and blades.
Always turn power to the ceiling fan OFF before replacing
light bulbs or working on your fan.
Never insert anything into the path of the fan blades while
the fan is in operation.
Never install a fan over a pool or spa.
Never operate a fan that has been damaged in any way.
Install the fan according to the instructions in this
manual.
If the fan does not work:
Refer to the Troubleshooting Tips in this Owner’s Manual.
Call Technical Support at 1-888-227-2178.
Contact your local Authorized Service Center.
Our Web site at www.CasablancaFanCo.com contains
additional information on Casablanca products,
troubleshooting, and Authorized Dealer or Service
Centers. Please do not return this product to the store.
Please take a moment to locate the model number for your fan (see below) and record this information on the Warranty
page inside the front cover of your Owner’s Manual if it does not appear there already. The model number is found on
the fan identiîš½cation sticker afîš½xed to the fan under the trim ring in the location shown below:
Isotope®
HANGER TYPE
MODEL #C30G45L
Memphis, TN
C30G45L
Fan Identication Sticker
Model Number
RECORD MODEL NUMBER BEFORE INSTALLATION!
Isotope
®
3
42900-01 • 07/10/13 • © Casablanca Fan Company
Circuit Breaker
(Trip breaker for the
circuit you will be
working on)
Fuse Box
(Remove fuse for the
circuit you will be
working on)
18"
84"
70"
SAFE USE
INTRODUCTION
BEFORE YOU START
From bottom
edge of blade
to îš¾oor
From wall to
end of blade
Dimensions indicated are the minimum
allowable for proper installation.
• CAUTION: RISK OF ELECTRICAL SHOCK! Installation is to be in accordance with the National Electrical Code, ANSI/
NFPA 70-1999, and local codes. If you are unfamiliar with the wiring codes, you should use a qualiîš½ed electrician.
To avoid overheating and possible damage to other equipment, do not install control to a receptacle, îš¾uorescent
light îš½xture, motor-operated appliance, or transformer-supplied appliance.
• This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling
fan installations. If it is not, a new box must be installed.
• This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. The maximum
current requirement for the fan with light îš½xture is 1.67 amps. The fan uses about .83 amp or 100 watts. Maximum
light current is about .83 amps or 100 watts of lighting.
• Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy, make
sure all wires are within the canopy and that no wires are being pinched.
• WARNING: Do not bend the blade brackets when installing the brackets, balancing the blades, or cleaning the fan.
Do not insert foreign objects in between the rotating fan blades.
Unpacking
Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them against
the parts listed in the Parts Guide. Before discarding packaging materials, be certain that all parts have been removed.
For the best performance and for your warranty to remain valid,
useîš«onlyîš«genuineîš«Casablancaîš«blades,îš«lightîš«îš¿xtures,îš«andîš«accessories.
• The blades in each pack are matched for equal weight
to assure smooth fan operation. If more than one fan
is being installed, be careful not to mix blades from
different cartons.
• Inspect the contents of your carton for possible
shipping or handling damage. If parts are missing or
damaged, call 1-888-227-2178.
• It is always a good idea to have an assistant to help
with the installation.
• When cleaning, painting, or working near your fan,
be very careful of the fan and blades. Always turn the
power OFF to the ceiling fan before working on it or
replacing lightbulbs.
• Never insert anything into the path of the fan blades
while the fan is in operation.
• Never install a fan over a pool or spa.
• Never operate a fan that has been damaged
i n a ny w ay. Fo r as s i s t a n c e i n o b t a i n i n g
se r v i c e , c a l l C a sa b l an c a Fan Comp an y a t
1-888-227-2178 or contact your local authorized
Casablanca dealer.
From wall to
center of fan


Product specificaties

Merk: Casablanca
Categorie: Ventilator
Model: Isotope 59023

Heb je hulp nodig?

Als je hulp nodig hebt met Casablanca Isotope 59023 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Casablanca

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator