SCS30
Solar Powered
Hanging Scale
Operation Manual
CARDINAL SCALE MFG. CO.
8551-0967-0M Rev A PO BOX 151
ï‚·
WEBB CITY, MO 64870
12/14 PH
(
417
)
673-4631
ï‚·
FAX
(
417
)
673-5001
www.detectoscale.com
Technical Support: Ph: 866-254-8261 techsupport@cardet.com ï‚Ÿ
8551-0967-0M Rev A ï‚Ÿ SCS30 Operation
SPECIFICATIONS
Power: Solar Cell (min. 400 LUX)
Operating Temperature: 32 to 104º F (0 to 40 º C)
Display: Five digit, seven segment, 1.0 inch (25 mm) high LCD
Annunciators: lb, kg, 


 


 (Zero), (Solar Charge Status)
Capacity: 30lb x 0.02 lb (15kg x 0.01kg)
UNPACKING
Before beginning installation of your scale, make certain it has been received in good
condition. When removing the scale from its packing, inspect it for signs of damage, such as
exterior dents and scratches. Keep the carton and packing material for return shipment if it
should become necessary. It is the responsibility of the purchaser to file all claims for any
damages or loss incurred during transit. You should have the following items:
(1) SCS30 Scale
(2) S-Hooks
(1) Bow Assembly
(1) Ring Assembly
(2) Pan Bow Nuts
(2) Wing Nut 5/16-18
(1) Pan
SETUP
1. Insure that the light available is adequate to power
the scale (typically an average lighted room is 400
LUX. This is adequate to power the scale.
NOTE: Make sure nothing is shading the solar cell
from the available light. Low lighting will result in the
scale display showing Lo
Lo
Lo
LoLo.
2. Referring to Figure No. 1, install S-Hook on top loop
of scale.
3. Hang scale from a support that is strong enough to
support the scale PLUS the weight of the item to be
weighed.
4. Follow the Hanging Assembly instructions to
compete the required assembly.
5. The scale has been calibrated with the enclosed
hanging assembly. In order to display zero, the
hanging assembly must be attached.
6. Scale is now ready to use.
WARNING! Failure to attach the scale to a support of sufficient strength
using a connector to hold the scale PLUS the weight of the item to be
weighed can result in the scale coming loose and damaging the scale
and/or injuring the operator and persons nearby.
Figure No. 1
8551-0967-0M Rev A ï‚Ÿ SCS30 Operation
HANGING ASSEMBLY
The SCS30 is shipped with a bow and pan
hanging assembly. The hanging assembly is
made up of four (4) main components.
S-Hook
Bow
Ring and bow attachment hardware (Pan Bow
Nuts and 5/16-18 Wing Nuts)
Pan
Assemble the hanging assembly as illustrated in
Figure No. 2. The hanging assembly is then
attached to the lower loop on the scale. Place
pan in Ring.
OPERATION
1. Hang scale from a secure position with
minimum 400 LUX lighting level. Make sure
nothing is shading the solar cell from the
available light.
2. Referring to Figure No. 3, press Zero Button
to zero scale.
3. To change between units (lb to kg or kg to lb),
press and hold Zero Button for approximately
5 seconds.
4. Place item to be weighed in pan.
5. Display will show weight of item.
6. Remove product and press Zero Button if
required before weighing next item.
DO’S AND DON’TS
ï‚· DO hang scale from a support that is strong enough to support the weight of the scale
PLUS the weight of the material to be weighed. The more rigid the support the better.
ï‚· DO ensure that the scale is not shaded from the available light.
ï‚· DO avoid shock loading the scale, i.e. do not drop heavy loads in the pan.
ï‚· DO check the hanging assembly wing nuts on a regular basis to ensure they are tight.
 DO check on a regular basis the scale’s supporting hardware to ensure that it continues
to provide the strength necessary to support the weight of the scale PLUS the item to be
weighed.
ï‚· DO NOT spray; water directly on the scale.
ï‚· DO clean scale using a damp, soft cloth and mild detergent.
ï‚· DO NOT use acetone, alcohol, or other volatile solvents for cleaning.
Zero
Button
Figure No. 2
S-Hook
Bow
Rin
g
Pan
Figure No. 3
Pan Bow Nut
5/16-18 Win
g
Nut


Product specificaties

Merk: Cardinal Detecto
Categorie: Keukenweegschaal
Model: MCS-20P

Heb je hulp nodig?

Als je hulp nodig hebt met Cardinal Detecto MCS-20P stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Keukenweegschaal Cardinal Detecto

Handleiding Keukenweegschaal

Nieuwste handleidingen voor Keukenweegschaal

Catler

Catler KS 4020 Handleiding

15 December 2024
Vivax

Vivax KS-505P Handleiding

14 December 2024
Girmi

Girmi PS05 Handleiding

10 December 2024
Girmi

Girmi PS04 Handleiding

10 December 2024
Ardes

Ardes AR1PA4WW Handleiding

10 December 2024
Pyrex

Pyrex SB-720 Handleiding

9 December 2024
Rosti

Rosti Mensura Handleiding

5 December 2024
Smeg

Smeg KSF01 Handleiding

5 December 2024