Cadac 2 Cook 2 Classic Handleiding

Cadac Fornuis 2 Cook 2 Classic

Lees hieronder de 📖 handleiding in het Nederlandse voor Cadac 2 Cook 2 Classic (88 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 43 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/88
503-0617 LEV9
MODEL No: 202M0
28mBar & 50mBar
USER INSTRUCTIONS
LIVE THE BRAAI LIFE
NOTE! PRODUCT MAY VARY FROM ILLUSTRATIONS
2 COOK CLASSIC 2
PERMIT 1002-145/2-RSA-17-A
GB DE DK ES FR IT NL NO PL SE SI FI
11
CAUTION
Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
must be provided.
IMPORTANT
Read these instructions carefully so as to familiarise yourself with the appliance before ting the appliance to a gas cylinder.
Retain these instructions for future reference.
GB
1. General
• This is an economic gas appliance designed for an optimal cooking experience using environment friendly LP gas.
• The appliance conforms to BS EN 484: 2019 and SANS 1539:2017
• This appliance may only be used with an approved hose and regulator (A 2.8kPa hose and regulator supplied with this unit in South
Africa)
• Note that gures in this user manual are shown for visual purposes only and may differ to your appliance.
• Please read all the instructions and warnings on the appliance before use.
• It is important that all gas connections have been correctly connected to prevent any gas leaks.
• Do not use a leaking, damaged or malfunctioning appliance.
• This appliance requires a hose and regulator to operate.
• Ensure that the appliance is used in a well-ventilated area.
• Handle the appliance with care, do not drop it.
• When using a pot, the minimum recommended pot size is 150mm and maximum pot size is 300mm.
• The gas cylinder is to be used in an upright position only.
• Read the instructions before using the appliance.
• For outdoor use only!
2. Safety information
These instructions are for your safety and to help you avoid risk of injury and/or damage. All
warranties will become void if you do not follow these instructions.
• The hose and seal on the regulator must be checked for wear or damage before every use
and before connecting to the gas cylinder.
• In the event of light back (where the ame burns back and ignites at the jet) immediately
turn off the gas supply by rst closing the control valve onthe gas cylinder and then the
appliance valve. After the ame is extinguished remove the regulator and check the
condition of its seal, replace the seal if in doubt. Re-light the appliance. Should the ame
persistently light back again return the product to your authorised CADAC repair agent.
• Ensure the appliance is used away from ammable materials. Minimum safe distances;
above the appliance 1.2 m, at the rear and sides 600mm.
• Do not use an appliance that is leaking, damaged or which does not operate properly.
• Ensure that the gas cylinder is tted or changed in a well-ventilated location, preferably
outdoors, away from any sources of ignition, such as naked ames and away from other
people.
• Keep gas cylinders away from heat and ame. Do not place on a stove or any other hot
surface.
• Ensure that the assembled product is stable and does not rock.
• Never leave the appliance unattended when lit.
• If there is a leak on your appliance (smell of gas), turn off the gas supply, rstly at the gas
cylinder and then on your appliance by turning the respective knobs fully clockwise. Take
them outside immediately into a well-ventilated ame-free location where the leak may be
detected and stopped.
• This appliance consumes oxygen and needs ventilation for optimum performance and for
safety of those in close proximity.
• Room ventilation is important for the efcient performance of the appliance and for the
safety of the occupants in the room.
• The room where this appliance is used should have a window or a door that can be opened
or partially open during use. If there is no window or door available for room ventilation,
extra ventilation must be installed for your sefety.
• If you wish to check for leaks on your appliance, do it outside. Do not try to detect leaks
using a ame, use soapy water. The correct way is to smear the joints with soapy water. If
bubbles form then there is a gas leak. Immediately turn off the gas supply rst by closing the control valve on the gas cylinder and
then the appliance valve, check that all the connections are properly tted. Re-check with soapy water. If a gas leak persists return the
product to your CADAC dealer for inspection / repair.
• Do not modify the appliance. Do not use it for anything for which it has not been designed.
• During use, parts of the appliance will become hot (particularly the burner) Avoid touching hot parts with bare hands. The use of
gloves is recommended.
• Keep young children away from the appliance at all times.
• Do not twist or pinch the hose.
• Do not move the appliance during use.
• Do not use the appliance without the Potstands being in place and properly located.
• Turn off the gas supply at the gas container after use.
• Do not modify the appliance, any modication may be dangerous.


Product specificaties

Merk: Cadac
Categorie: Fornuis
Model: 2 Cook 2 Classic

Heb je hulp nodig?

Als je hulp nodig hebt met Cadac 2 Cook 2 Classic stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis Cadac

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis