Intrusion Alarm Systems | B443 Plug-in Cellular, HSPA+ (3G+)
B443 Plug-in Cellular, HSPA+ (3G+)
www.boschsecurity.com
uRemote programming and monitoring of compatible
Bosch control panels
uConfigured directly from Bosch Remote
Programming Software eliminating the need for
separate configuration
The B443 provides 3G/4G IP communication over a
GPRS/EDGE/UMTS/HSPA+ cellular network by
plugging into any compatible Bosch control panel or
B450 Conettix Plug-in Communicator Interface. Typical
applications are:
• Alarm reporting to a central station
• Remote control panel programming through Remote
Programming Software with supported control panels
• Remote monitoring and control through a mobile
application with supported control panels
• Personal notification using SMS for compatible
control panels
The B443 is built for a wide variety of secure
commercial and industrial applications. Flexible end-
to-end path supervision, 128-bit to 256-bit AES
encryption, and anti-substitution features make B443
desirable for high security and fire monitoring
applications.
Notice
Cellular capability requires an Installer Services
account and appropriate data plan.
System overview
Callout
Callout
Callout
Callout Callout á…³
á…³
á…³
ᅳᅳ Description
Description
Description
Description Description Callout
Callout
Callout
Callout Callout á…³
á…³
á…³
ᅳᅳ Description
Description
Description
Description Description
1 B443 7 Remote PC’s networkᅳ ᅳ
connection
2 Compatible control panel 8 Remote PC running Remoteá…³ á…³
Programming Software
3 Antenna cable 9 Personal SMS notificationá…³ á…³
4 Magnetic base antenna 10 Ethernet connectioná…³ á…³
5 Base station on wirelessá…³
carrier’s network
11 Central monitoring stationá…³
6 IP network cloud á…³
Functions
IP communication via Cellular
The B443 uses Conettix IP protocol, SIA DC-09 UDP,
and CVS-IP on supported control panels that supports:
• Flexible polling intervals
• Resistance to Denial of Service attacks
• Anti-replay/anti-substitution keys using Conettix
Easy installation, troubleshooting, and
maintenance
• No networking expertise required at field site (no
firewall or router settings)
• No computer or special tools required for installation
and troubleshooting
• Diagnostic LEDs for on-site troubleshooting
LED Function
Blue (STATUS) System status Indicator
Red Unacceptable signal strength
Yellow Marginal signal strength
1 Green Good signal strength
2 Green Very good signal strength
Remote programming of Bosch control panels
The B443 supports secure remote programming of
compatible Bosch control panels.
Personal notification and control
On supported control panels, the B443 supports the
Bosch Remote Security Control mobile application and
can be configured for SMS personal notification
reports to mobile phones.
Certifications and approvals
Region Regulatory compliance/quality marks
Europe CE EMC, LVD, R&TTE, RoHS B443
EN5013
1
EN-ST-000245 EN-
ST-000245_B450_B450-
M_442_443_2021_04_25
USA UL UL 365 - Police Station Connected Bur-
glar Alarm Units
UL UL 636 - Holdup Alarm Units and Sys-
tems
UL UL 864 - Standard for Control Units and
Accessories for Fire Alarm Systems
UL UL 985 - Household Fire Warning Sys-
tem Units
UL UL 1023 - Household Burglar Alarm Sys-
tem Units
UL UL 1076 - Proprietary Burglar Alarm
Units and Systems
UL UL 1610 - Central Station Burglar Alarm
Units
CSFM see www.boschsecurity.com (the Bosch
website)
Region Regulatory compliance/quality marks
FCC Part 15 Class B
FDNY-
CoA
6307 B465_NYC_CoA_6307
FDNY-
CoA
6173
FDNY-
CoA
6286 D7412GV4 D9412GV4 NYC COA
6286 2018-2021
FDNY-
CoA
6196
Canada ULC CAN/ULC S303 - Local Burglar Alarm
Units and Systems
ULC CAN/ULC S304 - Standard for Signal Re-
ceiving Center and Premise Burglar
Alarm
ULC CAN/ULC S545 - Residential Fire Warn-
ing System Control Units
ULC CAN/ULC S559 - Fire Signal Receiving
Centres and Systems
ULC ULC-ORD C1023 - Household Burglar
Alarm System Units
ULC ULC-ORD C1076 - Proprietary Burglar
Alarm Units and Systems
ULC S1871-20121210
IC ICES-003 - Information Technology
Equipment (ITE)
Singapore iDA
Installation/configuration notes
Mounting considerations
Mounting considerations
Mounting considerations
Mounting considerationsMounting considerations
The module plugs into any compatible control panel,
available in a variety of enclosures.
Wiring considerations
Wiring considerations
Wiring considerations
Wiring considerationsWiring considerations
The module connects to any compatible control panel
without tools or physical wiring for power. When used
with the B450, the B450 is wired to the control panel
data bus. The cellular module has a screw on SMA
antenna connection.
Cellular service considerations
Cellular service considerations
Cellular service considerations
Cellular service considerationsCellular service considerations
The module is shipped pre-activated for Bosch Cellular
service on the Verizon cellular network. A valid service
contract is required prior to ordering.
GPRS/EDGE/UMTS/HSPA+ required.
Compatibilities
Compatibilities
Compatibilities
CompatibilitiesCompatibilities
2 | B443 Plug-in Cellular, HSPA+ (3G+)
Control panels B9512G/B9512G-E, B8512G/B8512G-E
B6512
B6512/B5512/B4512/B3512, B5512E/
B4512E/B3512E control panel with firmware
v2.03 or higher (direct insertion)
The B443 is compatible with most Bosch control
panels when used with a B450 Conettix Plug-in
Communicator Interface. Refer to the B450
datasheet for complete control panel
compatibility listings.
Cellular 4 Bands GPRS: 850/900/1800/1900 MHz
5 Bands: UMTS/HSPA: 800/850/900/
AWS1700/1900/2100 MHz
Cellular technology compatibility
Device Cellular networks
2G
(CDMA)
3G
(CDMA
)
GPRS
(GSM)
HSPA+
(GSM)
4G
(LTE
)
B440/
B440-
C*
X X
B441/
B441-
C*
X
B442* X
B443* X X
B444* X
*Check for availability in your region.
Commercial Fire and Burglary applications
Approved for Commercial Fire/Burglary applications as
sole, primary, or secondary communications path
when the system is installed to the NFPA-72
specification
Parts included
Quan
tity
Component
1 B443 Conettix Plug-in HSPA+ Cellular Communicator
1 Antenna
1 Literature pack
Technical specifications
Electrical
Electrical
Electrical
ElectricalElectrical
Current
(operating)
Standby: 35 mA
Alarm: 150 mA
Voltage (operating) 12 VDC nominal
Mechanical
Mechanical
Mechanical
MechanicalMechanical
Board Dimensions 50 mm x 93.5 mm x 15.25 mm (2 in x 3.68 in x
0.60 in)
Antenna (included) • Magnetic base omni-directional
• 2.5 m (8.2 ft) cable with SMA connector
SIM card • 3V/1.8V SIM (compliant with GSM
11.12 recommendation)
Environmental
Environmental
Environmental
EnvironmentalEnvironmental
Operating
temperature
-10°C to +55°C (+14°F to +131°F)
Relative humidity 5 - 93% at +32°C (+90°F) non-condensing
Environmental
class
III
Usage Indoor
US certification Open Development Certified
Canada
certification
Rogers certified
North America
certification
PTCRB certified
CE certification EN50130-4, EN61000-6-3, EN60950
Ordering information
B443 Plug-in Cellular, HSPA+ (3G+)
Multi-function 3G/4G cellular communicator providing
IP communication over a GPRS/EDGE/UMTS/HSPA+
cellular network
Order number B443
Accessories
SIM-HSPA-ATT SIM card, AT&T US
Contains one AT&T (US) wireless network SIM card for
the B443 Conettix Plug-in HSPA+ Cellular
Communicator.
Order number SIM-HSPA-ATT
ITS-SIM-TMO SIM card, T-Mobile US
Contains one T-Mobile (US) wireless network SIM card
compatible with the B443 Conettix Plug-in HSPA+
Cellular Communicator.
Order number ITS-SIM-TMO
B443-ATT Plug-in HSPA withAT&T SIM
This kit contains one B443 communicator and one
AT&T SIM card.
Order number B443-ATT
B443-TMO HSPA+ PLUG-IN W/ TMO SIM
This kit contains one B443 communicator and one T-
Mobile SIM card.
Order number B443-TMO
3 | B443 Plug-in Cellular, HSPA+ (3G+)


Product specificaties

Merk: Bosch
Categorie: Niet gecategoriseerd
Model: B443
Kleur van het product: Zwart
Breedte: 50 mm
Diepte: 93.5 mm
Hoogte: 15.25 mm
Type stroombron: DC
Soort apparaat: Splitser voor mobiele netwerken
Datanetwerk: 3G, 4G
Aantal SIM cards: 1
Bedrijfstemperatuur (T-T): -10 - 55 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 93 procent

Heb je hulp nodig?

Als je hulp nodig hebt met Bosch B443 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Bosch

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Festo

Festo VPPI Handleiding

21 November 2024
Festo

Festo SFAB Handleiding

21 November 2024
Festo

Festo SFAH Handleiding

21 November 2024
Festo

Festo DRRD-12 Handleiding

21 November 2024
Festo

Festo SDE3 Handleiding

21 November 2024
Festo

Festo SFTE Handleiding

21 November 2024
Festo

Festo CRVZS-5 Handleiding

21 November 2024