Bosch B299 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Bosch B299 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 154 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Intrusion Alarm Systems | B299 Expansion module, SDI2
B299 Expansion module, SDI2
www.boschsecurity.com
uProvides point identification for up to 100
connected addressable initiating devices using
POPITs
uSupervises wiring to devices for circuit integrity
uExpands the number of points in the system
uCompact size
uInterconnect wiring connectors for easy installation
The B299 POPEX Module is an SDI2 compatible
device. The module communicates to the control panel
over the SDI2 bus, and provides support for up to 100
POPIT (Point Of Protection Input Transponder)
devices. This occurs over a single expansion loop using
two pairs of terminals.
System overview
Each module installs in the control panel enclosure or
in an adjacent approved enclosure. Future system
expansion is very economical as the module supports
zone expansion through supporting D9127U/T POPIT
modules and POPIT’ed detectors. The POPIT modules
can be placed anywhere along the two-wire data
expansion loop from the module.
Certifications and approvals
Region Regulatory compliance/quality marks
USA ANSI-
SIA
CP-01-2010-Control Panel Standard -
Features for False Alarm Reduction
UL Underwriters Laboratories
UL UL 1023 - Household Burglar Alarm Sys-
tem Units
UL UL 1076 - Proprietary Burglar Alarm
Units and Systems
Region Regulatory compliance/quality marks
UL UL 1610 - Central Station Burglar Alarm
Units
UL UL 1635 - Standard for Digital Alarm
Communicator System Units
UL UL 294 - Standard for Access Control
Units and Systems
UL UL 365 - Police Station Connected Bur-
glar Alarm Units
UL UL 609 - Standard for Local Burglar
Alarm Units and Systems
UL UL 636 - Holdup Alarm Units and Sys-
tems
UL UL 864 - Standard for Control Units and
Accessories for Fire Alarm Systems
(10th edition)
UL UL 985 - Household Fire Warning Sys-
tem Units (6th edition)
FM Central Station
FM Local Protective Signaling
FM Remote Station
CSFM California Office of The State Fire Mar-
shall
FCC Part 15 Class B
Region Regulatory compliance/quality marks
Canada ULC Underwriters Laboratories of Canada
ULC CAN/ULC S303 - Local Burglar Alarm
Units and Systems
ULC CAN/ULC S304 - Standard for Signal Re-
ceiving Center and Premise Burglar
Alarm
ULC CAN/ULC S545 - Residential Fire Warn-
ing System Control Units
ULC ULC-ORD C1023 - Household Burglar
Alarm System Units
ULC ULC-ORD C1076 - Proprietary Burglar
Alarm Units and Systems
IC ICES-003 - Information Technology
Equipment (ITE)
Installation/configuration notes
Mounting
Mount the module into the enclosure’s 3-hole
mounting pattern using the mounting screws and
mounting bracket.
Wiring
Use the control panel SDI2 terminals labeled R, Y, G, B
(PWR, A, B, COM) when wiring to the module.
Connect the control panel terminals to the module
terminals labeled R, Y, G, B (PWR, A, B, COM). You can
also use the SDI2 interconnect cable.
Compatibility
POPIT devices D9127U/T POPIT module
ZX776Z/ZX794Z PIR motion detector
ZX835 TriTech motion detector
ZX935Z/ZX938Z PIR motion detector
ZX970 TriTech motion detector
D278S 12V smoke base
D298S 24V smoke base
F220-B6PM POPIT smoke (master)
F220-B6PS POPIT smoke base
Parts included
Quan
tity
Component
1 Module
1 Hardware pack
Quan
tity
Component
1 Interconnect cable
1 Installation manual
Technical specifications
Properties
Dimensions 2.9 in x 5.0 in x 0.6 in
(73.5 mm x 127 mm x 15.25 mm)
Weight 11.2 oz (0.30 kg)
Environmental considerations
Relative humidity 5% to 93% at +32°C (+90°F)
Temperature (operating) 0°C to +49°C (+32°F to +120°F)
Power requirements
Current Standby: 35 mA + total device current
Alarm: 35 mA + total device current
Voltage (input) 12 VDC
Wiring
Terminal wire size 12 AWG to 22 AWG (2.0 mm to 0.65
mm)
SDI2 wiring Maximum distance – Wire size
(unshielded wire only): 200 ft (60 m) -
22 AWG (0.65 mm), 500 ft (152 m) -
18 AWG (1.02 mm)
POPIT loop wiring Maximum wire length: 1800 ft (548 m)
- 22 AWG (0.65 mm), 4600 ft (1402
m) - 18 AWG (1.02 mm)
Ordering information
B299 Expansion module, SDI2
Provides system expansion support for up to 100
POPIT devices
Order number B299
2 | B299 Expansion module, SDI2
Represented by:
Europe, Middle East, Africa: Germany: North America: Asia-Pacific:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
emea.securitysystems@bosch.com
emea.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
www.boschsecurity.com
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
onlinehelp@us.bosch.com
www.boschsecurity.us
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
© Bosch Security Systems 2020 | Data subject to change without notice
16544648587 | en, V10, 25. Jun 2020


Product specificaties

Merk: Bosch
Categorie: Niet gecategoriseerd
Model: B299
Gewicht: 300 g
Breedte: 73.5 mm
Diepte: 127 mm
Hoogte: 15.25 mm
Connectiviteitstechnologie: Bedraad
Type stroombron: DC
Kleur behuizing: Zwart
Ingangsspanning: 12 V

Heb je hulp nodig?

Als je hulp nodig hebt met Bosch B299 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Bosch

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Festo

Festo VPPI Handleiding

21 November 2024
Festo

Festo SFAB Handleiding

21 November 2024
Festo

Festo SFAH Handleiding

21 November 2024
Festo

Festo DRRD-12 Handleiding

21 November 2024
Festo

Festo SDE3 Handleiding

21 November 2024
Festo

Festo SFTE Handleiding

21 November 2024
Festo

Festo CRVZS-5 Handleiding

21 November 2024