Bogen ZX3 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Bogen ZX3 (32 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 203 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
Zone Controller with
Universal Telephone Interface
UTI312 Model
Installation and Use Manual
© 2005 Bogen Communications, Inc.
All rights reserved.
Specifications subject to change without notice.
54-2120-01D 1203
Notice
Every effort was made to ensure that the information in this manual
was complete and accurate at the time of printing. However,
information is subject to change.
FCC Statement (Part 15) - Radio Frequency Interference
The Universal Telephone Interface generates and uses radio frequency
energy and if not installed and used in strict accordance with the
manufacturer's instructions, may cause interference to radio and
television reception. Testing is being conducted for compliance with
the limits for a Class B device in accordance with the specifications in
Part 15 of the FCC Rules and Canadian D.O.C. regulations. This testing
is designed to provide reasonable protection against such interference.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause interference to
radio or television reception, which can be determined by turning the
UTI312 unit off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient the radio or TV receiving antenna.
- Relocate the UTI3 2 unit with respect to the radio or TV receiver1
or vice-versa.
- Plug the UTI3 2 unit into a different outlet so that it and the radio1
or TV receiver are on different branch circuits.
If necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions. The user may find
the following booklet, "How To Identify and Resolve Radio-TV
Interference Problems," helpful. This booklet was prepared by the
Federal Communications Commission (FCC) and is available from the
U.S. Government Printing Office, Washington, DC 20402. Stock order
No. 004-000-00345-4.
Federal Communications Commission (FCC) Statement
(Part 68)
This equipment is component registered with the Federal
Communications Commission (FCC) in accordance with Part 68 of its
rules. In compliance with the rules, be advised of the following:
Registered equipment may not be used with Coin Telephone Lines.
Equipment may be used with Party Lines in areas where state tariffs
permit such connections and when equipment is adaptable for such
service.
This equipment is registered as follows:
Registration Number - CD2PA13BUTI312
Ringer Equivalence - 1.4B
If trouble is experienced, the equipment should be disconnected from
the interface to determine if this equipment, or the telephone line is
the trouble source. If the equipment is determined to be
malfunctioning, it should not be reconnected until repairs are effected.
Repairs to this equipment, other than routine repairs, can be made
only by the manufacturer or its authorized agents.
If the equipment causes harm to the telephone network, the local
telephone company may temporarily discontinue your service and, if
possible, notify you in advance. If advance notice is not practical, you
will be notified as soon as possible. You will be given the opportunity
to correct the problem and informed of your right to file a complaint
with the FCC.
The local telephone company may make changes in its facilities,
operations, or procedures that could affect the proper functioning of
your equipment. If they do, you will be given adequate notice in writing
to allow you an opportunity to maintain uninterrupted telephone
service.
Important Safety Information
Always follow these basic safety precautions when installing and using
the system:
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the product.
3. DO NOT block or cover the ventilation slots and openings. They
prevent the product from overheating. DO NOT place the product
in a separate enclosure or cabinet, unless proper ventilation is
provided.
4. Never spill liquid on the product or drop objects into the
ventilation slots and openings. Doing so may result in serious
damage to the components.
5. Repair or service must be performed by a factory authorized
repair facility.
6. The product is provided with a UL-CSA approved, 3-wire ground
type plug. This is a safety feature. DO NOT defeat the safety
purpose of the grounding type plug. DO NOT staple or otherwise
attach the AC power supply cord to building surfaces.
7. DO NOT use the product near water or in a wet or damp place
(such as a wet basement).
8. DO NOT use extension cords. The product must be installed
within 6 feet of a grounded outlet receptacle.
9. DO NOT install telephone wiring during a lightning storm.
10. DO NOT install telephone jacks in a wet location unless the jack
is specifically designed for wet locations.
11. Never touch uninsulated wires or terminals, unless the line has
been disconnected at the paging or controller interface.
12. Use caution when installing or modifying paging or control lines.
Contents
3
Introduction ......................................................4
Voice Channel ..............................................................4
Background Music........................................................4
Signaling Tones ..............................................................4
Other Features ............................................................4
Package Contents ........................................................4
Panel Descriptions............................................5
Installation ........................................................6-7
Mounting ........................................................................6
ZX3 Module Installation & Jumper Selections ......7
Telephone Interface
Wiring Connections & Setup ..........................7-10
Telephone System Connections ..............................7
PBX Analog Station Port ............................................7
PBX Loop Start Trunk Port ......................................8
PBX Ground Start Trunk Port ..................................8
Trunk Disconnect ........................................................9
PBX Page Port Contact..............................................9
PBX Page Port VOX ....................................................9
Override Input ..............................................................10
90V Night Ring Input ..................................................10
Other Connections ..........................................11
Night Ringer Contact..................................................11
Tone Trigger Inputs 1& 2 ..........................................11
Background Music Inputs ..........................................11
UTI312 AUX Contacts ..............................................11
ZX3 Module Connections................................12
ZX3 Module Paging Output Connections ............12
ZX3 AUX Contacts ....................................................12
ZX3 Power Supply Output........................................12
Controls ............................................................ 31
Paging Level....................................................................13
Music Level ....................................................................13
Tone Level......................................................................13
Night Ring Level ..........................................................13
Limiter Threshold ........................................................13
Features & Operation ......................................1 14- 7
Zones .............................................................................. 41
Paging Zone Groups....................................................14
All-Call Zone Group ..................................................14
Auto Select Zone Group ..........................................15
Override Zone Group & Tone..................................15
Night Ring Zone Group & Tone ..............................15
Tone Trigger 1& 2 Zone Groups & Tones ............15
Code Call Zone Group & Tones..............................16
AUX Relay Contact ....................................................16
Flexible Dialing..............................................................16
Confirmation Tone ......................................................16
Pre-Announce Tone ....................................................16
Dialing Time-out ..........................................................17
DTMF Block ..................................................................17
Trunk Disconnect ........................................................17
Timers ............................................................................ 71
Calling Party Controlled Disconnect ......................17
Setup Tone......................................................................17
Reset Default Values ....................................................17
Priority Levels ..............................................................17
System Programming ......................................18-22
Paging Zone Groups ....................................................18
All-Call Zone Group ..................................................18
Auto Select Zone Group ..........................................18
Tone Zone Groups ......................................................19
Code Calling..................................................................19
DTMF Block ..................................................................19
Timers ............................................................................ 91
AUX Relay Contact ....................................................20-21
Flexible Dialing..............................................................22
Flexible Dialing Reference Chart..............................22
Feature Codes & Defaults ..............................23-26
Specifications ....................................................27
Block Diagram, UTI312 ..................................28
Block Diagram, ZX3 ........................................29
Limited Warranty ............................................30


Product specificaties

Merk: Bogen
Categorie: Niet gecategoriseerd
Model: ZX3

Heb je hulp nodig?

Als je hulp nodig hebt met Bogen ZX3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Bogen

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg GTA-6 Handleiding

21 November 2024
Smeg

Smeg KIT6CX Handleiding

21 November 2024
Senal

Senal SCS-98 Handleiding

21 November 2024
Senal

Senal ASM-6 Handleiding

21 November 2024
Senal

Senal ASM-MNTKIT Handleiding

21 November 2024
Senal

Senal SMS-45 Handleiding

21 November 2024
Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024