Bogen SAX1R Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Bogen SAX1R (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 12 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
SAX1R
Stereo Aux Input
Module
Features
• Gain/Trim control
• Bass and treble
• Audio Gating with threshold and duration adjustments
• Variable signal ducking when muted or gated
• Fade back from mute level
• 4 levels of available priority
• Can be muted from higher priority modules
• Can mute lower priority modules
• Stereo signal or mono summed signal operation
Block Diagram
50 Spring Street, Ramsey, NJ 07446 U.S.A.
201-934-8500 • Fax: 201-934-9832
www.bogen.com
© 2005 Bogen Communications, Inc.
54-2054-01C 0906
Specifications subject to change without notice.
LIMITED WARRANTY; EXCLUSION OF CERTAIN DAMAGES
The Bogen SAX1R Module is warranted to be free from defects in material or workmanship for three
(3) years from the date of sale to the original purchaser. Any part of the product covered by this warranty
that, with normal installation and use, becomes defective will be repaired or replaced by Bogen, at our
option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department,
50 Spring Street, Ramsey, NJ 07446, USA. The product will be returned to you freight prepaid. This
warranty does not extend to any of our products that have been subjected to abuse, misuse, improp-
er storage, neglect, accident, improper installation or have been modified or repaired or altered in any
manner whatsoever, or where the serial number or date code has been removed or defaced.
THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE WARRANTY AND
THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WAR-
RANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED
AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen’s liability arising out of
the manufacture, sale or supplying of products or their use or disposition, whether based upon war-
ranty, contract, tort or otherwise, shall be limited to the price of the product. In no event shall Bogen
be liable for special, incidental or consequential damages (including, but not limited to, loss of profits,
loss of data or loss of use damages) arising out of the manufacture, sale or supplying of products,
even if Bogen has been advised of the possibility of such damages or losses. Some States do not
allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have
other rights which vary from State to State.
Products that are out of warranty will also be repaired by the Bogen Factory Service Department --
same address as above or call 201-934-8500. The parts and labor involved in these repairs are war-
ranted for 90 days when repaired by the Bogen Factory Service Department. All shipping charges in
addition to parts and labor charges will be at the owner's expense. All returns require a Return
Authorization number.
7/22/2008
Gain
Provides control over the level of input signal that can be applied to the
internal signal buses of the main unit. Allows a way to balance the input lev-
els of various devices so that the main unit controls can be set to relatively
uniform or optimum levels.
Bass & Treble (Treb & Bass)
Provides separate controls for Bass and Treble cut and boost. The Bass control
affects frequencies below 00 Hz and Treble affects frequencies above 8 kHz.1
Clockwise rotation provides boost; counterclockwise rotation provides cut.
Center position provides no affect.
Gate - Threshold (Thresh)
Controls the minimum necessary input signal level to turn on the module’s
output and apply mute signal to the main unit's buses. Clockwise rotation
increases the necessary signal level required to produce output and mute
lower priority modules.
Gate - Duration (Dur)
Controls the amount of time the output and mute signal of the module
remains applied to the main unit’s buses after the input signal falls below the
required minimum signal level (set by the threshold control).
Ducking (Duck)
Controls the level of the output signal from the module when it has been
requested to mute/gate its’ output. The range is adjustable from no reduc-
tion in level to full muting of the output signal.
Connections
Uses standard RCA connectors to make connections to the module’s input.
The inputs are quasi-balanced to reduce the chance of ground loops while still
being compatible with unbalanced signal sources.
When assigned to separate buses, the "A" labeled input will feed signal to all
"A" labeled controls and output on the main unit. Likewise for the "B" labeled
controls.
Jumper Selections
Priority Level*
This module can respond to 4 different levels of priority.
Priority 1is the highest priority. It mutes modules with
lower priorities and is never muted. Priority 2 can be muted
by Priority modules and mutes modules set for 3 or 4.1
Priority 3 is muted by either Priority or 2 modules and1
mutes priority 4 modules. Priority 4 modules are muted by
all higher priority modules.
*The number of priority levels available is determined by the
amplifier in which the modules are used.
Bus Assignment
This module can be set to operate in stereo mode, where
input A audio is delivered only to the main unit’s A channel,
and likewise for the B input. Or, the module can be set to
combine the stereo into a mono signal and make it available
to all buses within the main unit.
Module Installation
1. Turn off all power to the unit.
2. Make all necessary jumper selections.
3. Position module in front of desired module bay
opening, making sure that the module is right-
side up.
4. Slide module on to card guide rails. Make sure
that both the top and bottom guides are
engaged.
5. Push the module in to the bay until the faceplate
contacts the unit’s chassis.
6. Use the two screws included to secure the mod-
ule to the unit.
Gating
Gating (turning off) of the module's output when insuffi-
cient audio is present at the input can be disabled.
Detection of audio for the purpose of muting lower priori-
ty modules is always active regardless of this jumper setting.
WARNING:
Turn off power to unit and make all jumper
selections before installing module in unit.


Product specificaties

Merk: Bogen
Categorie: Niet gecategoriseerd
Model: SAX1R
Gewicht: 79 g
Stroomvoorziening: 24VDC
Frequentiebereik: 10 Hz - 40 kHz
Afmetingen (B x D x H): 25 x 76 x 76 mm

Heb je hulp nodig?

Als je hulp nodig hebt met Bogen SAX1R stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Bogen

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd