Blaze B820 Handleiding

Blaze Heater B820

Lees hieronder de 📖 handleiding in het Nederlandse voor Blaze B820 (12 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
Revision B
Installaon Instrucons
Contemporary and Stylish
Keep instrucons for future reference
Glen Dimplex Australia proudly supports the acvies of Landcare Australia through its membership of the AHHA
B520
B820
1
CONTENTS
1. INSTALLATION ................................................................... 1
1.1. IMPORTANT INFORMATION .................................... 1
1.2. MASONRY INSTALLATION ........................................ 2
1.3. ZERO CLEARANCE INSTALLATION ............................ 4
1.4. INSTALLING THE BAFFLE PLATE ............................... 7
1.5. INSTALLING THE FIRE BRICKS 7 ..................................
1.6. TECHNICAL DRAWINGS 8 ...........................................
1. INSTALLATION
1.1. IMPORTANT INFORMATION
The unit must be installed according to all manufacturers’
instrucons included in manual. The manufacturer is not this
liable for installaons that do not meet the requirements
outlined in this manual.
Most building regulatory authories in Australia require any
wood heater installaon to comply with Installaon Standard
AS/NZS 2918. Diî…¼erent states and councils may have varying
regulaons. Check local building regulaons before installing
the appliance.
All Blaze wood heaters have been tested to ensure they will
meet the appropriate safety standard requirements if the
instrucons in this manual are followed. As the safety and
emissions performance can be aî…¼ected by altering the
appliance, no modicaons are allowed without wrien
permission from the manufacturer.
WE RECOMMEND THAT THE INSTALLATION OF YOUR BLAZE
WOOD HEATER BE CARRIED OUT BY A QUALIFIED INSTALLE R.
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE
INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE
APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING
CODE OR CODES.
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH
THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS
OF AS/NZS 4012 & AS/NZS 4013 WHERE REQUIRED BY THE
REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE
IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING
‘TESTED TO AS/NZS 4012 & AS/NZS 4013’.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED
FOR COMPLIANCE WITH AS/NZS 4012 & AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM
COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS
CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED
IN THE FIRST INSTANCE.
CAUTION: CRACKED AND BROKEN COMPONENTS, EG. GLASS
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION
UNSA . FE
THE INSTALLATION INSTRUCTIONS IN THIS MANUAL
APPLY TO THE BLAZE B52 AND B820 INSERT WOOD 0
HEATER MODELS.
THEY HAVE BEEN TESTED FOR EMISSIONS AND
EFFICIENCY AND COMPLY ACCORDING TO AS/NZS
4012:2014 & AS/NZS 4013:2014.
2
1.2. MASONRY INSTALLATION
Refer to this secon for clearance requirements and
instrucons if the heater is to be in a masonry installaon.
Clearances to Combusble Materials
The dimensions given in the table and image below represent
the minimum clearance (in millimetres) to combusble
materials, such as a mantelpiece with columns, when installed
in a non-combusble replace. If a combusble mantelpiece is
present, a Mantelpiece Shield must be installed (refer to
secon ‘Mantelpiece Shield’).
B520
B820
A (Width between mantelpiece columns)
900
1020
B (Height to mantelpiece from hearth)
970
1080
C (Height to mantelpiece above air vents)
400
450
D (Distance ide wall from side of facia) to s
200
250
Floor Protector (Hearth)
The dimensions given in the table and image below represent
the minimum hearth sizes (in millimetres), when installed in a
non-combusble replace, with either cement sheet (thermal
conducvity not greater than 0.33W/m K) or brick. º
ï‚· The dimensions can be larger than the minimum
dimensions given here if desired.
 The oor protector may be laid directly on the
combusble oor.
 For more details and variaons on oor protectors refer
to AS/NZS 2918 Clause 2.2, 3.3.1, & 3.3.2.
B820
Hearth Material (or
equivalent)
Cement
sheet
Brick
Cement
sheet
Brick
E (Thickness)
15
110
15
110
F (Width)
900
900
1000
1000
G (Depth from door)
400
300
500
300
For variaons to clearances relave to a combusble
mantelpiece refer to AS/NZS 2918 Clause 3.4.2.


Product specificaties

Merk: Blaze
Categorie: Heater
Model: B820

Heb je hulp nodig?

Als je hulp nodig hebt met Blaze B820 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater Blaze

Handleiding Heater

Nieuwste handleidingen voor Heater