Black And Decker PP610 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Black And Decker PP610 (48 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 203 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/48
1
INSTRUCTION MANUAL
POLE SAW
Thank you for choosing BLACK+ ! DECKER
PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON.
If you have a question or experience a problem with your BLACK+ go to DECKER purchase, http://www.blackanddecker.com/instantanswers
If you cant find the answer or do not have access to the Internet, call 1- -544-6986 from 8 a.m. to 5 p.m. EST Mon. - Fri. to speak with an 800
agent. Please have the catalog number available when you call.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
VEA EL ESPANOL EN LA CONTRAPORTADA. INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO.
CATALOG NUMBER
PP610
To register your new product, call 1-800-544-6986 or visit www.BlackandDecker.com/NewOwner
KEY INFORMATION YOU SHOULD KNOW:
READ INSTRUCTIONS THOROUGHLY
BEFORE OPERATING!
DO NOT OVER-TENSION CHAIN. Refer to “Adjusting Chain
Tension for proper method of tensioning chain.
Retighten chain frequently during first two hours of use.
2
provided on the circuit(s) or outlet(s) to be used for the pole saw.
Receptacles are available having built-in GFCI protection and may be
used for this measure of safety.
• WARNING: To reduce the risk of electric shock, use only with an
extension cord intended for outdoor use, such as an extension cord of
cord type SW-A, SOW-A, STW-A, STOW-A, SJW-A, SJOW-A,
SJTW-A. or SJTOW-A.
• Extension Cord. Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one heavy enough
to carry the current your product will draw. An undersized extension
cord will cause a drop in line voltage resulting in loss of power and
overheating. The following table, shows the correct size to use
depending on cord length and nameplate ampere rating. If in doubt,
use the next heavier gage. The smaller the gage number, the heavier
the cord.
- To reduce the risk of disconnection of pole saw cord from the
extension cord during operating make a knot as shown in Figure
below.
SAFETY GUIDELINES - DEFINITIONS
It is important for you to read and understand this manual. The information it
contains relates to protecting YOUR SAFETY and PREVENTING PROBLEMS.
The symbols below are used to help you recognize this information.
DANGER: Indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if
not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if
not avoided, may result in minor or moderate injury.
CAUTION: Used without the safety alert symbol indicates a
potentially hazardous situation which, if not avoided, may result in
property damage.
IMPORTANT SAFETY RULES
SAVE THESE INSTRUCTIONS
READ AND UNDERSTAND ALL INSTRUCTIONS.
WARNING: When using electric gardening appliances, basic
safety precautions should always be followed to reduce the risk of fire,
electric shock, and personal injury, including the following:
WARNING:
For safe operation read and understand owner’s manual.
• Avoid Dangerous Environment. Don’tusepolesawindamporwet
locations.
Don’t Use In Rain.
• Keep Children Away. All visitors should be kept at a distance from
work area.
• Dress Properly. Do not wear loose clothing or jewelry. They can be
caught in moving parts. Use of rubber gloves and substantial footwear
is recommended when working outdoors. Wear protective hair
covering to contain long hair.
• Use Safety Glasses. Always use face or dust mask if operation is
dusty.
• Use Right Appliance. Do not use pole saw for any job except that for
which it is intended.
• Ground Fault Circuit Interrupter (GFCI) protection should be
Minimum Gauge for Cord Sets
Volts Total Length of Cord in Feet
120V 0-25 26-50 51-100 101-150
240V 0-50 51-100 101-200 201-300
Ampere Rating
More Not more American Wire Gauge
Than Than
0 - 6 18 16 16 14
6 - 10 18 16 14 12
10 - 12 16 16 14 12
12 - 16 14 12 Not Recommended
3
Receptacles are available having built-in GFCI protection and may
be used for this measure of safety.
WARNING:
Some dust created by power sanding, sawing,
grinding, drilling, and other construction activities contains chemicals
known to cause cancer, birth defects or other reproductive harm.
Some examples of these chemicals are:
 •leadfromlead-basedpaints,
 •crystallinesilicafrombricksandcementandothermasonryproducts,and
 •arsenicandchromiumfromchemically-treatedlumber.(CCA)
Your risk from these exposures varies, depending on how often you do this
type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, such as those
dust masks that are specially designed to filter out microscopic particles.
• Avoid prolonged contact with dust from power sanding, sawing,
grinding, drilling, and other construction activities. Wear protective
clothing and wash exposed areas with soap and water. Allowing dust
to get into your mouth, eyes, or lay on the skin may promote absorption of
harmful chemicals.
WARNING:
Use of this tool can generate and/or disburse
dust, which may cause serious and permanent respiratory or
other injury. Always use NIOSH/OSHA approved respiratory
protection appropriate for the dust exposure. Direct particles away
from face and body.
CAUTION: Wear appropriate personal hearing protection during
use. Under some conditions and duration of use, noise from this
product may contribute to hearing loss.
Double Insulation
Double insulated tools are constructed throughout with two separate
layers of electrical insulation or one double thickness of insulation
between you and the tools electrical system. Tools built with this
insulation
system are not intended to be grounded. As a result, your tool
is equipped with a two prong plug which permits you to use extension
cords without concern for maintaining a ground connection. Double NOTE:
insulation does not take the place of normal safety precautions when
operating this tool. The insulation system is for added protection against
injury resulting from a possible electrical insulation failure within the tool.
•Usethe
extension cord retainer
(15)describedinthismanual.
• Avoid Unintentional Starting. Do not carry plugged-in pole saw with
finger on switch. Be sure switch is off when plugging in.
• Do not Abuse Cord. Never carry pole saw by cord or yank it to
disconnect from receptacle. Keep cord from heat, oil, and sharp edges.
• Do not grasp the exposed cutting blades or cutting edges when
picking up or holding the pole saw.
• Do Not Force Pole Saw. It will do the job better and with less likelihood
of a risk of injury at the rate for which it was designed.
• Do Not Overreach. Keep proper footing and balance at all times.
• Stay Alert. Watch what you are doing. Use common sense. Do not
operate pole saw when you are tired.
• Disconnect Pole saw. Disconnect the pole saw from the power supply
when not in use, before servicing, when changing accessories such as
chains, and the like.
• Store Idle Pole saws Indoors. When not in use, pole saw should be stored
indoors in dry, and high or locked-up place out of reach of children.
• Maintain Pole saw With Care. Keep cutting edge sharp and clean for
best performance and to reduce the risk of injury. Follow instructions
for lubricating and changing accessories. Inspect pole saw cord
periodically, and if damaged, have it repaired by an authorized service
facility. Inspect extension cords periodically and replace if damaged.
Keep handles dry, clean, and free from oil and grease.
• Check Damaged Parts. Before further use of the pole saw, a guard or
other part that is damaged should be carefully checked to determine
that it will operate properly and perform its intended function. Check for
alignment of moving parts, binding of moving parts, breakage of parts,
mounting, and any other condition that may affect its operation. A guard
or other part that is damaged should be properly repaired or replaced by
an authorized service center unless indicated elsewhere in this manual.
SAVE THESE INSTRUCTIONS
SPECIFIC SAFETY RULES
Electrical safety
This tool is double insulated; therefore no grounding wire is required. Always
check that the power supply corresponds to the voltage on the rating plate.
•GroundFaultCircuitInterrupter(GFCI)protectionshouldbeprovided
onthecircuit(s)oroutlet(s)tobeusedforthegardeningappliance.


Product specificaties

Merk: Black And Decker
Categorie: Niet gecategoriseerd
Model: PP610

Heb je hulp nodig?

Als je hulp nodig hebt met Black And Decker PP610 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Black And Decker

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd