B-Air Vantage VG-1500 Handleiding

B-Air Ontvochtiger Vantage VG-1500

Lees hieronder de đź“– handleiding in het Nederlandse voor B-Air Vantage VG-1500 (16 pagina's) in de categorie Ontvochtiger. Deze handleiding was nuttig voor 46 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Model: VG 1500
Industrial Dehumidifier
Operating Instructions
Read and save these instructions.
This instruction manual provides important
information concerning the use and care of the B-Air
Vantage 1500 Commercial Dehumidifier – Model VG
1500. Please read and follow these instructions in
order to ensure the safe operation and maximum
performance of your unit.
For any questions relating to the use and operation
of the unit, please contact: 877.800.2247 or email
info@b-air.com
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adaptor.
Use of an extension cord is not recommended
(see electrical safety section below)*.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Electrical Requirements
For 115V, 60Hz operation, a common grounded
outlet on a 15 amp circuit is required. If used in a
wet area, a ground fault interrupter (GFI) is required.
Built in Electrical Safety
For your safety and protection, this machine is
manufactured with a grounded plug on its power
cord. The power cord must be plugged into a
properly grounded receptacle. If a grounded
receptacle does not exist, have one installed by a
certified electrician. Do not cut or remove the
grounding prong on the power cord plug. We
recommend that this electrical circuit/receptacle
operate under a separate breaker or fuse.
*If use of an extension cord is unavoidable, it must
have a minimum of 12 AWG conductors if it is 25
feet long or less and 10 AWG conductors if it is
greater than 25 feet long.
Water Removal
The dehumidifier is equipped with an internal
condensate pump to remove the water that is
collected from the air. This allows the water to be
pumped 25 feet with the attached hose. For
emptying of the condensate pump for storage see
STORAGE section of this manual.
REQUIREMENTS FOR SAFE OPERATION
Never allow unauthorized individuals or children to
operate the unit at any time.
It is recommended that anyone operating the
VG 1500 wear the proper personal protective
equipment and follow safe work practices in
accordance with federal, state, provincial and
employer regulations.
Check condition of power cord(s) before using them.
Damaged cords can cause fatal electric shock
and/or equipment damage.
Power cord(s) should never be exposed to water,
heat, sharp, or abrasive objects; in addition, they
should never be kinked or crushed. Avoid tightly
wrapping the cords to prevent kinking of the internal
wires. Always replace damaged power cords
immediately.
Never pull the unit by the power cord.
Avoid running over power cords with utility
equipment and vehicles.
CAUTION: As with any piece of electrical
equipment, always make sure that the unit is
turned “OFF” prior to disconnecting it from an
electrical outlet. Failure to do so will cause
“arcing”, and could result in personal injury, fire
hazards and/or damage to the unit. Do not
disconnect the power cord from supply
receptacle while the unit is operating.
WARNING: To reduce risk of electrical shock, do
not expose this unit to water or rain – it is
certified for INDOOR USE ONLY. Do not touch
the electrical outlet or power cord(s) with wet
hands or while standing on a wet or damp
surface.
WARNING: Risk of electrical shock, or contact
with moving parts leading to personal injury or
death! Turn unit OFF and disconnect power cord
from supply receptacle before taking off any
removable covers.
WARNING: The dehumidifier will restart without
warning after a temporary power interruption. If
all covers are not in place, the intended
protection from the motorized impeller will not
be present - keep clear of the motorized impeller
to reduce the risk of injury.
WARNING: To reduce risk of fire or electrical
shock, do not use the AT450S with any solid-
state speed control device.
CAUTION: For general dehumidification use
only. Do not use to dehumidify hazardous or
explosive materials and vapors.
WARNING: This dehumidifier is not classified as
“intrinsically safe” and should not be used in the
following hazardous locations as defined by the
Underwriters Laboratories: Class I Division 1,
Class I Division 2, Class I Zone 0, Class I Zone 1,
Class I Zone 2, Class II Division 1, Class II
Division 2, Class III Division 1, Class III Division
2. Refer to the UL web site:
http://www.ul.com/hazloc/define.htm.
For use in potentially hazardous locations that
fall outside of the above designations, always
consult a certified industrial hygienist before
use. Do NOT use this equipment in any
atmosphere that is or may be immediately
dangerous to life or health (IDLH), combustible,
flammable, explosive, oxygen deficient, and/or
contains odors, vapors, gases or particulates
that exceed permissible exposure levels. Such
atmospheres may require the use of intrinsically
safe equipment, specific engineering controls,
and personal protective equipment in
accordance with Occupational Safety and Health
Administration (OSHA), Environmental
Protection Agency (EPA), Canadian Standards
Association (CSA), and other federal, state,
provincial and local regulations.
WARNING: Pressurized Unit. This equipment is
factory-charged with R-410A refrigerant and is
under pressure. Only qualified personnel should
attempt repairs to the refrigeration system. Do
not puncture or cut into the refrigeration piping.
WARNING: The unit should never be operated
without the compressor terminal cover properly
secured in place on top of the compressor;
otherwise, serious injury or death could result.
The cover is required to be securely in place to
allow proper operation for the safety overload,
and to act as a shield if the hermetic terminals
blow out of the compressor shell.
OPERATION
1. Place dehumidifier inside area to be dried.
2. Make sure all windows and doors are closed to
the outside and seal off the wet area from any
unaffected areas.
3. Route condensate hose into a drain, or a very
large container.
4. Press the On/Off button to activate the
dehumidifier.
Power Button
The dehumidifier is turned on or off by pressing the
power button. When the dehumidifier is started, the
hour meter will display the cumulative hours.
Purge Button
In normal operation, the pump will automatically
empty the reservoir. Pressing this button allows
manual emptying of the reservoir. Press and hold
the pump purge button until its reservoir is empty.
Always manually purge the water reservoir before
transport or storage. Turn off the power and allow
the plugged in dehumidifier to rest 5 minutes before
the final purge. The purge button can be activated
even when the power button is in the off position.
Time Counter
The counter will accumulate and display the total
running hours of the unit in 1/10 of an hour. This
counter cannot be reset, and therefore might show
some hours on a new product that has had quality
control testing performed on it.
Defrost Indicator
Under certain conditions, ice may build up on the
evaporator coil. When that occurs, the unit will
automatically go into a defrost cycle, during which
the “Defrost Indicator” lamp will be lit. When the ice
has melted, the defrost cycle will end and the
system will reverse back to normal operation.


Product specificaties

Merk: B-Air
Categorie: Ontvochtiger
Model: Vantage VG-1500

Heb je hulp nodig?

Als je hulp nodig hebt met B-Air Vantage VG-1500 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ontvochtiger B-Air

Handleiding Ontvochtiger

Nieuwste handleidingen voor Ontvochtiger