Audio-Technica ES925H/DS5 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Audio-Technica ES925H/DS5 (4 pagina's) in de categorie Microfoon. Deze handleiding was nuttig voor 40 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
1
â– Introduction
Thank you for purchasing this product. Before using the product, read through
the user manual to ensure that you will use the product correctly. Please keep
this manual for future reference.
â– Features
• Modular microphone system comprised of an ES Series capsule, gooseneck
assembly, and power module.
• RGB LEDs built into both the desk stand power module and gooseneck
assembly indicate the on/off status of the microphone.
• Includes external control function for device control from the capacitive touch
switch.
• The capacitive touch switch can be set to any of three operating modes:
“touch-on/touch-off”, “touch-to-talk” and “touch-to-mute”.
â– Safety precautions
Although this product was designed to be used safely, failing to use it correctly
may result in an accident. To ensure safety, observe all warnings and cautions
while using the product.
â– Cautions for the product
• Do not subject the product to strong impact to avoid malfunction.
• Do not disassemble, modify or attempt to repair the product.
• Do not handle the product with wet hands to avoid electric shock or injury.
• Do not store the product under direct sunlight, near heating devices or in a
hot, humid or dusty place.
â– Notes on use
• Do not swing or pull the product. Doing so may cause disconnection or
damage.
• The circuitry in the microphone takes about 30 seconds to stabilize after power
is supplied. You may hear some audio disturbance during startup.
• The connectors are equipped with a special RFI-shielding mechanism. If you
remove or replace the connector, you may adversely affect the microphone’s RFI
immunity. The Audio-Technica Crimp Tool (ATCT) and shield parts are required to
shorten the cable and reinstall the connector while maintaining the RFI immunity.
• Install the microphone on a flat, unobstructed mounting surface. Make sure
that the sound source is not below the mounting surface.
• Depending on the surface finish of a table, the desk stand power module may
leave marks on the table.
• Do not excessively bend the gooseneck assembly, rotate the ends of the
capsule, or pull on them. Doing so may cause disconnection or malfunction.
• The product is a modular system comprised of a microphone element,
gooseneck assembly and power module. Make sure the parts are firmly
attached before use.
• Do not remove the rubber O-ring on the power module connecting part at the
lower section of the gooseneck assembly.
• When attaching parts, remove the black cap on the capsule connecting part
of the gooseneck assembly. Do not remove the silicone part at the end of
the capsule connecting part.
Silicone part
Do not remove
â– Switch settings
To reduce low-frequency ambient noise (such as footsteps or air conditioning
noise), room reverberation, and mechanically coupled vibrations as much as
possible, turn on the low-cut filter switch ( ) on the bottom of the power
module.
ES925H6/DS5
ES925H12/DS5
ES925H15/DS5
ES925H18/DS5
ES925H21/DS5
ES925H24/DS5
User Manual
HYPERCARDIOID CONDENSER
MODULAR GOOSENECK MICROPHONE
WITH 5-PIN DESK STAND POWER MODULE
2
â– Assembly
1. • Insert the gooseneck assembly (c) while rotating it into the desk stand
power module (d).
• Tighten until it does not rotate, and use the hex wrench (h) to tighten the
set screw (g) and set the gooseneck assembly in place.
• Connect the capsule (b) to the gooseneck assembly, and attach the
windscreen (a).
* If the parts are not sufficiently tightened together, problems may occur
such as the LED colors of the gooseneck assembly and power module
not matching or sound is not output.
a
b
c
g
h
d
2. Connect the included cable to the connector (e) on the reverse side of the
desk stand power module, and pass the cable through the wire slot (f).
e
f
â– LED color
1 2 3
OFF RED GREEN
YELLOW
4 5 6 7
BLUE
MAGENTA
CYAN WHITE
â– Wiring
1
2
5
3
4
SHIELD : GND (PIN1)
YELLOW : HOT (PIN2)
RED : COLD (PIN3)
BLACK : GND (PIN1)
BLUE : CONTACT CLOSURE (PIN5)
WHITE : LED CONTROL (PIN4)
3
â– Switch setting and functions
Contact
Closure
GND
MIC
4
6
7. LED status
3. Action 4. Contact
closure
status
2. Switch
Function 6. LED color
5.
Audio
status
1. Control


Product specificaties

Merk: Audio-Technica
Categorie: Microfoon
Model: ES925H/DS5

Heb je hulp nodig?

Als je hulp nodig hebt met Audio-Technica ES925H/DS5 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Microfoon Audio-Technica

Handleiding Microfoon

Nieuwste handleidingen voor Microfoon

Sony

Sony ECM-322BMP Handleiding

22 November 2024
Sony

Sony ECM-S1 Handleiding

22 November 2024
Sony

Sony ECM-W3S Handleiding

22 November 2024
Sony

Sony ECM-W3 Handleiding

22 November 2024
Sony

Sony ECM-M1 Handleiding

22 November 2024
Sony

Sony XLR-H1 Handleiding

22 November 2024
Sony

Sony ECM-678 Handleiding

22 November 2024
Sony

Sony ECM-XYST1M Handleiding

22 November 2024