Atlas Sound AT100D Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Atlas Sound AT100D (6 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 226 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
1/1
AtlasSound.com
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
©2012 Atlas Sound L.P. All rights reserved. Atlas Sound is a trademark of Atlas Sound L.P. All other trademarks are the property of their respective owners. All specs are subject to change without notice. ATS004344 RevA 5/12
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Attenuator Installations
Wiring
Each terminal will hold up to 2-16AWG stranded wire. For larger wires or home run situations, a small length of wire and a wire nut are
recommended. Attach wire according to label on terminal block as shown to the right (Non-PA Models will not have the "VDC+" and "VDC-"
terminals).
*Install the unit with the terminal block on top. This will ensure that the OFF position is in the bottom.
Schematics for Priority Attenuators Power Switching Req. for -PA Attenuators
Use 2nd external relay
when paging switch is part
of a paging microphone.
This will reduce hum and
noise pickup from the mic.
RELAY SPECIFICATIONS:
Coil Voltage: Coil Current: 24 VDC
10MA
Contacts: SPDT-2Amp Rating
Relay has a protective cover.
WIRING REQUIREMENTS: (1) PAIR FOR AUDIO, (1) PAIR FOR RELAY
(-RM) Rack Mount
Drill holes in panel using the template to the right. Peel off adhesive
backing on escutcheon overlay. Align hole openings with holes in
panel and affix to surface. Remove knob and nut from attenuator.
Insert bushing through large hole in panel making sure that the small
indentation on the bracket lines up with the small hole in the panel.
Fasten attenuator to panel with the nut. Fit attenuator knob on shaft.
Tighten screw on knob to secure.
Dimensional Specifications
-RM Models supplied without a faceplate. All other models supplied with a single
faceplate. Double gang stainless steel faceplate can be ordered separately.
MODEL A B C
AT10 21
8" (54mm) 234" (70mm) 134" (45mm)
AT35 21
8" (54mm) 234" (70mm) 134" (45mm)
AT100 21
2" (64mm) 234" (70mm) 134" (45mm)
7⁄ "mm16
316"mm
3⁄ "mm8
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435 AtlasSound.com 1/5
©2011 Atlas Sound L.P. All rights reserved. Atlas Sound and Strategy Series are trademarks of Atlas Sound L.P. All other trademarks are the property of their respective owners. ATS001063 RevD 10/13
Commercial Attenuators
AT Series, E408 Series
Features
Models Feature a Range of Attenuation Steps (1.5dB or 3dB Steps) as
Well as Continuous to Meet Application and Budget Requirements
Wall Plates are Stainless Steel with Stamped and Filled or Screen Printed
Dial Scale, and a Skirted Black Knob (White and Ivory Plastic Plates with
Matching Skirted Knobs Also Available in Decora Style-D Series Only)
Popular Rack Mount Attenuator Versions are Available on the AT and E408
Series for Mounting on to Blank Panels in Equipment Cabinets
• All AT Models Mount into Most 1-Gang E.O. Boxes. (234" Deep)
• AT and E408 Series are UL Listed
Genenal Description
AT Series Industry Standard Auto Transformer. High-quality auto
transformer series provides the advantages of excellent frequency
response, low insertion loss and reliable performance for volume control
application in 25V/70.7V systems. Attenuation is accomplished in ten
make before break steps plus positive Off position. (No stop between
maximum and Off position to prevent switch damage). Contacts are
silver plated for noise-free operation. Features a removable terminal
block. Includes stainless steel plate, with stamped and filled or screen
printed dial scale and a skirted black knob. (White and ivory plastic plates
with matching skirted knobs also available in Decora style-see AT model
description chart).
E408 Auto Transformer with Precision Level Control. Specially designed
for attenuation in masking and sound reinforcement systems where fine
tuning of level control is required. Employs a ten-position, non-shorting
rotary switch without stop. Attenuation rate is 1.5dB per step. (All other
specifications are the same as the AT Series including the UL listing).
PA Series Priority Paging Option. Priority paging feature by-passes
the effect of the attenuator to provide program level selection of
individual emergency and paging signals at the amplifier. Option is
available on all AT attenuators. The SPDT relay is operated with 24VDC
at 10mA. Includes protective relay cover to ensure lasting trouble-free
performance. Terminations to the relay and attenuator are made via a
removable terminal block. (All other specifications except for dimensions
are the same as selected AT models).
RM Series Rack Mount Option. For attenuation convenience of
rack-mounted equipment in cabinets and consoles, the AT, E408
Series attenuators are available without mounting plate for rack panel
installation. Attractive matte black polycarbonate dial scale overlay with
adhesive backing replaces the mounting plate. Includes skirted black
knob. Overlay size is 29 square (51mm). (To order, simply add RM after
the selected attenuator model number. Example: AT10-RM or AT10-
PARM.) (Dial scale overlays to retrofit existing installations are available,
see Model HX23.)
AT10 / AT35 / AT100 Series
AT10 / AT35 / AT100 Series Face Plate Options
Attenuators are available in Classic Stainless
or Decora(Decora available in Ivory or White)
E408-100
RM Series
HX21-B HX22-W
Replacement Knobs
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435 AtlasSound.com 2/5
©2011 Atlas Sound L.P. All rights reserved. Atlas Sound and Strategy Series are trademarks of Atlas Sound L.P. All other trademarks are the property of their respective owners. ATS001063 RevD 10/13
Specfications
AT10-(PA)
Power Rating * 10 Watts
UL Listing
Attenuation Per Step 3dB
Total Attenuation 33dB**
Insertion Loss .4dB
Plate Size 1 gang
Resistance None
AT35-(PA)
Power Rating * 35 Watts
UL Listing
Attenuation Per Step 3dB
Total Attenuation 27dB
Insertion Loss .6dB
Plate Size 1 gang
Resistance None
AT100-(PA)
Power Rating * 100 Watts
UL Listing
Attenuation Per Step 3dB
Total Attenuation 27dB
Insertion Loss .6dB
Plate Size 1 gang
Resistance None
E408-100
Power Rating * 100 Watts
UL Listing
Attenuation Per Step 1.5dB
Total Attenuation 15dB
Insertion Loss .6dB
Plate Size 1 gang
Resistance None
* Continuous
** These units have two steps of 6dB before off position.
Note: Attenuation curve is steeper for a 25-volt line
Architect and Engineer Specifications
AT Series Attenuator(s) shall be Atlas Sound AT Series Model
____________ auto transformer or approved equal. The power rating shall
be __________ and attenuation range shall be _________dB. Attenuation
per step for AT-____ shall be 8 steps of 3dB and 6dB each for the last
two positions. Attenuator shall be a step type control with a positive off
position. There shall be no stop between the maximum and off positions
(AT Series only). Switch shall have silver plated contacts to eliminate
noise and contact loss. All terminations must be made via a removable
terminal block. Unit(s) shall be supplied with one of the following single
gang face plates to be noted by model number suffix: Standard stain less
steel faceplate (with dial scale to indicate attenuator position), Decora
style plastic face plate-Ivory color, Decora style plastic face plate-White
color. All models are designed to mount in a standard E.O. box.
E408 UL Listed attenuator shall be Atlas Sound Model E408-100 auto
transformer or approved equal. The power rating shall be 100W. The
at tenu ation per step shall be 1.5dB. Unit shall be a step type control with
a positive off position. There shall be no stop between the maximum and
off positions. Switch shall have silver plated contacts to elimi nate noise and
contact loss. The attenuator shall be mounted to a standard gang stainless
steel wall plate which mounts to a standard E.O. box.
RM Option Attenuator shall be Atlas Sound Model ____________
[(AT, E408 (-RM)] or ap proved equal. Face plate shall be replaced
by an adhesive matte black poly car bon ate dial scale escutcheon for
attachment to a rack mount panel. Escutcheon size shall be 2" SQ.
PA Option Specified AT Series attenuators include a priority relay. Relay
shall be an SPDT, 24 VDC type securely mounted to the attenuator
assembly wired at the factory. Relay shall include a protective cover.
AT10 (dc) (-PA) (-RM)
AT35 (dc) (-PA) (-RM)
AT100 (dc) (-PA) (-RM)
(-PA)
Priority
Announce Circuit
Option
(-RM)
Rack
Mount
Option
Faceplate Options:
d = D - Decora Style Faceplate
Ivory and White inserts, trim ring
and knobs icluded.
If there is not the above 1 letter suffix,
the attenuator is shipped with the
standard stainless steel faceplate or
is the RM version without a faceplate.


Product specificaties

Merk: Atlas Sound
Categorie: Niet gecategoriseerd
Model: AT100D

Heb je hulp nodig?

Als je hulp nodig hebt met Atlas Sound AT100D stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Atlas Sound

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd