Ariston Thermo PC 640 TGH Handleiding

Ariston Thermo Fornuis PC 640 TGH

Lees hieronder de 📖 handleiding in het Nederlandse voor Ariston Thermo PC 640 TGH (36 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 61 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/36
AUS
1
HOB
PC 640 T X AUS
PC 640 N T X AUS
PC 750 T GH AUS
Contents
Installation, 2-7
Positioning
Electrical connection
Gas connection
Data plate
Burner and nozzle specifications
Description of the appliance, 8
Overall view
Start-up and use, 9
Practical advice on using the burners
Precautions and tips, 10
General safety
Disposal
Maintenance and care, 11
Switching the appliance off
Cleaning the appliance
Gas tap maintenance
Troubleshooting, 12
Operating Instructions
Français, 13 Español, 25English,1
FR ES
AUS
AUS
2
! Before operating your new appliance please read this
instruction booklet carefully. It contains important
information for safe use, installation and care of the
appliance.
! Please keep these operating instructions for future
reference. Pass them on to possible new owners of the
appliance.
Compliance with standards
This cooktop must be installed by an authorised
person in accordance with the requirements of local
gas and electrical authorities, as well as the latest
published versions of the following standards:
AS/NZS 5601 Gas Installations and pipe sizing
SAA Wiring Rules.
Positioning
! Keep packaging material out of the reach of children. It
can become a choking or suffocation hazard (
see
Precautions and tips
).
! The appliance must be installed by a qualified and
authorised professional according to the instructions
provided. Incorrect installation may cause harm to people
and animals or may damage property.
Kitchen Ventilation
Where the total input of all appliances exceeds 3
MJ/h for each cubic metre of the room or enclosure
volume, the space shall be ventilated by one of the
methods detailed below. For the purpose of
assessing the adequacy of ventilation, the space
that cannot be isolated by doors is the ‘volume of a
room’.
Natural ventilation direct from outside
Two permanent openings shall be provided directly
to outside. The openings shall be located to ensure
the distance between the top of the upper opening
and the ceiling of the room or enclosure, and the
distance between the bottom of the lower opening
and the floor of the room or enclosure does not
exceed 5% of the height of the room or enclosure.
The minimum free ventilation area provided by each
opening shall be calculated using the following
formula:
A = 3 × T
where
A = the minimum free ventilation area (cm2)
T = the total gas consumption of all appliances
(MJ/h)
The minimum vertical dimension of any free
ventilation opening shall be 6 mm.
NOTE 1 When used in this Clause, the term directly
to outside’ means any one of the following options,
provided that the ventilation path is unobstructed by
building material or insulation:
(a) Directly through an outside wall (preferred
option).
(b) Through to an outside wall but offset.
(c) Into a cavity ventilated to outside.
(d) Into an under floor space ventilated to outside.
(e) Into a roof space ventilated to outside.
NOTE 2
The two openings may be combined
provided that the top and bottom of the opening
reach the limits set by this Clause.
Natural ventilation via adjacent room
Two permanent openings shall be provided in the
room or enclosure. The openings shall be located to
ensure the distance between the top of the upper
opening and the ceiling of the room or enclosure,
and the distance between the bottom of the lower
opening and the floor of the room or enclosure does
not exceed 5% of the height of the room or
enclosure.
The minimum free ventilation area provided by each
opening shall be calculated using the following
formula:
A = 6 × T
where
A = the minimum free ventilation area (cm2)
T = the total gas consumption of all appliances
(MJ/h)
These requirements shall apply to all subsequent
rooms until a room is ventilated to outside, in
accordance with the previous section, or the total
input of the appliances does not exceed 3 MJ/h for
each cubic metre of the total volume of the
enclosure and rooms.
The minimum vertical dimension of any free
ventilation opening shall be 6 mm.
NOTE: :
: : : The two openings may be combined
provided that the top and bottom of the opening
reach the limits set by this Clause.
Liquid petroleum gas sinks to the floor as it is heavier
than air. Therefore, rooms containing LPG cylinders
must also be equipped with vents to allow gas to
escape in the event of a leak. As a result LPG
cylinders, whether partially or completely full, must not
be installed or stored in rooms or storage areas that are
below ground level (cellars, etc.). It is advisable to
keep only the cylinder being used in the room,
positioned so that it is not subject to heat produced by
external sources (ovens, fireplaces, stoves, etc. ) which
could raise the temperature of the cylinder above 50°C.
Installation
AUS
3
Adjacent cabinetry
The location of connection points is given in the
table on page 5 . For trouble-free operation of
appliances installed in housing units, the minimum
distances shown in fig.4 should be observed. It is
recommended that the adjacent kitchen surfaces
should be capable of withstanding temperatures of
65°C. Also, the following must be observed:
The appliance should be installed next to
cabinetry which is no taller than the top of the
cooker hob.
The wall in direct contact with the back panel of
the cooker must be made of non-flammable
material. During operation of the cooker, the back
panel of the cooker could reach a temperature of
50°C above room temperature.
Kitchen cabinets installed next to the cooker that
are higher than the top of the hob, must be at
least 600 mm from the edge of the hob itself.
If the hood is installed below a wall cabinet, the
latter must be at least 700 mm (millimetres) above
the surface of the hob.
Cabinets installed adjacent to the hood must be
at least 420 mm above the hob,
The following minimum
clearances to combustible
materials must be observed:
Minimum clearance from
edge of burner to side wall
must be 200 mm.
Minimum clearance from
edge of burner to rear wall
must be 55 mm.
Range hoods
Range hoods and overhead exhaust fans must be
installed according to manufacturers instructions
but in no case shall clearance from hob burners be
less than 600 mm for range hoods and 750 mm for
overhead exhaust fans.
If the hood is installed below a wall cabinet, the
latter must be at least 700 mm (millimetres) above
the surface of the hob.
Fitting the cooktop above an oven
When installing the cooktop above an oven, both the
electricity supply cable and the gas pipe or flexible
hose must not touch hot parts of the oven housing.
When installing above a built-under oven without
forced cooling ventilation, suitable air vents should
be provided for (inlet at least 200 cm² from the
bottom, outlet at least 120 cm² from the top part) to
allow adequate ventilation inside the housing unit.
Also a wooden panel should be installed beneath
the hob as insulation, positioning it at a minimum
distance of 15 mm from the hob housing
The installation cavity should have the dimensions
indicated in the figure. Fastening hooks are provided,
allowing you to fasten the hob to tops that are between
20 and 40 mm thick. To ensure the hob is securely
fastened to the top, we recommend you use all the
hooks provided.
555 mm
55 mm
475 mm
Hook fastening diagram
Hooking position Hooking position
for top H=20 mm for top H=30 mm
Front
Hooking position Back
for top H=40 mm
! Use the hooks contained in the accessory pack
Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This
must be placed at a minimum distance of 20 mm from
the lower part of the hob.
Ventilation
To ensure adequate ventilation, the back panel of the
cabinet must be removed. It is advisable to install the
oven so that it rests on two strips of wood, or on a
completely flat surface with an opening of at least 45 x
560 mm (
see diagrams
).
600mm min.
420mm min.
700mm min.


Product specificaties

Merk: Ariston Thermo
Categorie: Fornuis
Model: PC 640 TGH

Heb je hulp nodig?

Als je hulp nodig hebt met Ariston Thermo PC 640 TGH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis Ariston Thermo

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis