AMX HPX-N102-USB-PC Handleiding

AMX USB Hub HPX-N102-USB-PC

Lees hieronder de πŸ“– handleiding in het Nederlandse voor AMX HPX-N102-USB-PC (2 pagina's) in de categorie USB Hub. Deze handleiding was nuttig voor 9 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
QUICK START GUIDE
HPX-N102-USB-PC HydraPort Dual Charging USB Module
Overview
The HPX-N102-USB-PC Dual Charging USB Module (FG553-13) can be used in
conjunction with HydraPort HPX-600/900/1200/1600 and HydraPort Touch (7”/10”)
Connection Ports.
This module provides two user-accessible USB Power connections on the face of the
module, providing 2.1A USB power connections from the user's equipment to a remote
power supply (FIG. 1):
The HPX-N102-USB-PC receives it’s power from the (included) PSU2.1 USB Power
Supply (FG423-25). The PSU2.1 features two powered USB ports that provide up to
2.1A max per port (4.2A total across both ports):
Product Specifications
Installation
The following instructions describe installing the HPX-N102-USB-PC into HydraPort
HPX-600/900/1200/1600 and HydraPort Touch (7”/10”) Connection Ports.
For instructions on installing modules into the HPX-1600 Retractable Connection Port
(US and International versions), refer to the HPX-1600 Installation Manual - available to
view or download from www.amx.com.
Caution: Only use a manual screwdriver for the mounting instructions in this document.
Over-tightening the screws can hinder performance or damage the product.
1. Existing HydraPort Installations
For new HydraPort installations, skip to Step 2.
For existing HydraPort installations, the HydraPort Base Assembly must be un-mounted
from the surface before the HPX-N102-USB-PC module can be installed:
1. Cut/remove any cable ties that would restrict the removal of the HydraPort Base
Assembly.
2. Loosen the four mounting screws (located inside and at each end of the
HydraPort base assembly), in order to rotate the retaining tabs from under the
mounting surface.
Note that when the cover of the HydraPort base is open, only two of these screws
are visible. To access the other two mounting screws, tip the cover over to the
opposite open position (see FIG. 3).
3. Once the retaining tabs have been rotated out from under the mounting surface,
the HydraPort assembly can be lifted away from the mounting surface.
FIG. 4 provides a cutaway view of the End Cap, showing the retaining tabs in both
the loose position and the tightened (secure) position:
FIG. 1 HPX-N102-USB-PC DUAL USB POWER MODULE
FIG. 2 PSU2.1 - 2-PORT USB POWER SU PPLY
HPX-N102-USB-PC MODULE - SPECIF ICATIONS
Dimensions
(HWD):
Module: 0.98” x 2.05” x .276” (25 mm x 66 mm x 7 mm)
Note that β€œDepth” (D) represents the depth of the module faceplate
relative to the front of the connection ports.
Weight: .35 lbs (0.16 Kg)
USB Ports: (2) Type A USB Ports
USB Cables: (2) USB cables 6β€˜ (1.83 m) - connect the module to the USB Ports on
the PSU2.1 USB Power Supply
Enclosure: Matt black finished face plate (Polycarbonate plastic).
Compatibility: β€’ HPX-600: 6 Module Connection Port - (FG560-01-SL/BL)
β€’ HPX-900: 9 Module Connection Port - (FG560-02-SL/BL)
β€’ HPX-1200: 12 Module Connection Port - (FG560-03-SL/BL)
β€’ HPX-1600: 16 Module Retractable Connection Port
- (US - FG550-01-SL/BL, International - FG550-SL/BL)
β€’ HPX-MSP-7: 8 Module HydraPort Touch Connection Port
- (BL - FG571-07)
- (SL - FG571-08)
β€’ HPX-MSP-10: 10 Module HydraPort Touch Connection Port
- (SL - FG571-09)
- (BL - FG571-10)
Accessories: β€’ PSU2.1 USB Power Supply (FG423-25) (included)
PSU2.1 USB POWER SUPPLY - SPECIF ICATIONS
Dimensions (HWD): 1.26” x 2.17” x 3.15” (3.2 cm x 5.5 cm x 8 cm)
Weight: .25 lbs (93.3 g)
2 USB Ports/LEDs: β€’ 2 Charging Ports provide 2.1A USB charging (max per port)
β€’ 4.2A total is provided across both ports.
β€’ Blue LEDs on each USB port light to indicate that power is available.
Cable length =
6 feet (1.83 m)
USB Port
Power Status LED
(lights to indicate power)
Power Status LED
(lights to indicate power)
USB Port
PSU2.1 USB POWER SUPPLY - SPECIFICATIONS (CONT.)
Included
Accessories:
4 Power Plug Adapters:
β€’ NEMA 1-15 (for North America)
β€’ BS 1363 (for UK and Ireland)
β€’ CEE 7/16 Europlug (for most European countries)
β€’ AS/NZS 3112 (for Australia and New Zealand)
FIG. 3 HYDRAPORT BASE ASSEMBLY (SHOWN MOUNTED) - MOUNTING SCREWS LOCATIONS
FIG. 4 HYDRAPORT BASE ASSEMBLY (SHOWN MOUNTED) - MOUNTING SCREWS LOCATIONS
Β© 2015 Harman. All rights reserved. Hydraport, AMX, AV FOR AN IT WORLD, HARMAN, and their respective logos are registered trademarks of
HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective
companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom β€’ +44 1904-343-100 β€’ www.amx.com/eu/
93-0553-13 REV: B
Last Revised: 8/05/2015
2. Remove the End Cap and Existing Modules
Remove the End Cap as well as existing modules (as necessary, depending on how you
want the modules arranged) from one end of the HydraPort base assembly.
1. Remove the (silver) pivot screw and pivot pawl assembly in the center of the End
Cap (FIG. 5).
2. Remove the six (black) sheet metal screws that secure the End Cap to the
HydraPort assembly (locations circled in red below).
3. Gently slide the End Cap out of the HydraPort base assembly.
3. Insert the Dual USB Module into the HydraPort Base
1. Orient the module relative to the HydraPort base assembly so that the Module’s
faceplate is facing up, towards the mounting surface (FIG. 6).
2. Align the Mounting Notches on the module with the Mounting Rails on the
HydraPort base.
Note: Module faceplates are notched in a β€œtongue and groove" type fashion to ensure
that all modules are oriented correctly in the HydraPort. Note the orientation of the
notched faceplate on each module before sliding the module(s) into the HydraPort
assembly.
3. Slide the module into position.
4. Install any remaining modules into the HydraPort base.
4. Re-Install the End-Cap
Caution: Do not use a high-powered torque screwdriver. Over-tightening these screws
can damage the product.
1. Align the Mounting Notches on the End Cap with the Mounting Rails on the
HydraPort base.
2. Slide the End Cap into the HydraPort base until it is fully inserted against the end
of the base assembly.
3. Secure the End Cap with the six (black) sheet metal screws (removed in
Step 2 - 2; see FIG. 5).
4. Replace the (silver) pivot screw and pivot pawl assembly (removed in Step 2 - 1,
see FIG. 5) in the center of the End Cap.
5. Mount the HydraPort into the Mounting Surface
Caution: Do not use a high-powered torque screwdriver. Over-tightening these screws
can damage the product.
Note: For detailed instructions on installing the HydraPort base assembly, refer to the
HPX-600/900/1200/1600 and HydraPort Touch (7”/10”) Installation Guides (available
online at www.amx.com).
1. Carefully insert the HydraPort base into the cutout in the mounting surface.
2. Tighten the four mounting screws (loosened in Step 1, see FIG. 4) located inside
and at each end of the HydraPort base assembly, to rotate the retaining tabs into
locking position under the mounting surface.
3. Replace any cable ties that were removed in Step 1.
Connecting the USB Module to the PSU2.1 USB Power Supply
Plug the two USB cables from the USB module into the USB ports on the included
PSU2.1 Power Supply (see FIG. 2).
USB Power Supply Installation
Install the Appropriate Power Adapter
The PSU2.1 USB Power Supply comes with Power Adapters to accommodate various
wall outlet types. Select the Power Adapter that is appropriate for your locale and
mount it on the PSU2.1:
1. Align the mounting slots on the Power Adapter with the metal prongs on the
PSU2.1
2. Slide the adapter into place, until it β€œclicks” into it’s secure position (FIG. 7):
3. Plug the power supply (with Power Adapter installed) to a wall outlet.
Note that the (blue) Power Status LEDs light to indicate that the PSU2.1 is
receiving power.
4. Plug both USB cables from the USB Module into the PSU2.1.
Note: The PSU2.1 USB Power Supply is also available to purchase separately from AMX
(FG423-25).
Additional Documentation
Refer to the Products > Architectural Connectivity catalog page on www.amx.com
(Dealer Site) for additional product documentation.
FIG. 5 HYDRAPORT BASE ASSEMBLY (SHOWN MOUNTED) - MOUNTING/PIVOT SCREW LOCATIONS
FIG. 6 INSTALLING THE HPX-N102-USB-PC MODULE
HydraPort Base Assembly
Mounting Surface
End Cap
Interlocking tabs
PSU2.1 INCLUDED POWER ADAPTERS
NEMA 1-15 BS 1363 CEE 7/16 Europlug AS/NZS 3112
FIG. 7 INSTALLING A POWER ADAPTER ON THE PSU2.1
Power
Adapter
Release Button: Press to
release the power adapter
for removal.
PSU2.1
Power
Supply
Outputs


Product specificaties

Merk: AMX
Categorie: USB Hub
Model: HPX-N102-USB-PC

Heb je hulp nodig?

Als je hulp nodig hebt met AMX HPX-N102-USB-PC stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding USB Hub AMX

Handleiding USB Hub

Nieuwste handleidingen voor USB Hub