PACKAGE TERMINAL
AIR CONDITIONER/HEAT PUMP
Installation Instructions & Owner’s Manual
Standard and Remote Applications
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to know the
product better than the customer. This includes all safety
precautions and related items.
Prior to actual installation, thoroughly familiarize yourself
with this Instruction Manual. Pay special attention to all safety
warnings.
Often during installation or repair it is possible to place yourself
in a position which is more hazardous than when the unit is in
operation.
This manual must be left with the owner of the equipment.
19001 Kermier Road • Waller, TX 77484 • www.amana-ptac.com
© 2022 Daikin Comfort Technologies Manufacturing, L.P.
is a registered trademark of Maytag Corporation or its related companies
and is used under license. All rights reserved.
IO-931A
11/2022
This equipment complies with FCC radiation exposure limits. To ensure
compliance, human proximity to the antenna shall not be less than
20 cm during normal operations.
ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL,
ADJUST, SERVICE OR REPAIR(HEREINAFTER, “SERVICE”)
THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD
SERVICE THE EQUIPMENT. THE MANUFACTURER WILL
NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY
DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE
PROCEDURES. IF YOU SERVICE THIS UNIT, YOU ASSUME
RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE
WHICH MAY RESULT. IN ADDITION, IN JURISDICTIONS
THAT REQUIRE ONE OR MORE LICENSES TO SERVICE
THE EQUIPMENT SPECIFIED IN THIS MANUAL, ONLY
LICENSED PERSONNEL SHOULD SERVICE THE EQUIPMENT.
IMPROPER INSTALLATION, ADJUSTMENT, SERVICING OR
REPAIR OF THE EQUIPMENT SPECIFIED IN THIS MANUAL,
OR ATTEMPTING TO INSTALL, ADJUST, SERVICE OR REPAIR
THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT
PROPER TRAINING MAY RESULT IN PRODUCT DAMAGE,
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
WARNING
This device, which was assembled by Daikin Comfort Technologies
Manufacturing, L.P., contains a component that is classied as an
intentional radiator. This intentional radiator has been certied by the
FCC: FCC ID TF7M90-1000. And this international radiator has an
Industry Canada ID: IC 27830-M90IC1000.
And this device meets the applicable Industry Canada technical
specications.
The manufacturer of the intentional radiator (model no. M90H or M90S)
or FCC ID: TF7M90-1000 is Everex Communications Inc, which can be
contacted by (510)-687-0075 (www.everexcomm.net).
This device complies with Part 15 of the FCC’s Rules. Operation of this
device is subject to two conditions:
(1) This device may not cause harmful interference; and
(2) This device must accept any interference received, including
interference that may cause undesirable operation.
And this device meets the applicable Industry Canada technical
specication.
The FCC responsible party is Daikin Comfort Technologies
Manufacturing, L.P. , and may be contacted by calling 713-861-2500, or
at 19001 Kermier Rd., Waller TX 77484. (www.DaikinComfort.com)
2
WARNING
CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY
THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE
USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment o and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and
receiver.
—Connect the equipment into an outlet on a circuit dierent
from that to which the receiver is connected.
—Consult the dealer or an experienced radio/ TV technician
for help.
Contents
Unit Features 2 .................................................
Installation Instructions 5 .....................................
Wiring 7 ..........................................................
Operating Instructions 8 ......................................
LED to possible Error Code Mapping 9 .....................
Control Board User Inputs* 13 ...............................
Discharge Grille Orientation Options 14 ..................
Remote Thermostat ....................................... 15
PTAC Connect App ......................................... 19
Conguration Settings Chart ............................. 28
Wiring Diagrams 34 ............................................
IMPORTANT NOTE TO THE OWNER
This manual is to be used by qualied, professionally trained HVAC
technicians only. Goodman does not assume any responsibility
for property damage or personal injury for improper service
procedures or services performed by an unqualied person.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.
NOTE: Maximum allowable pressures for the low-pressure and
high-pressure side of the refrigeration system are 223 PSIG and
669 PSIG respectively. This unit is IPX4 rated.
Remember, it is responsibility to install the product safely your
and to know it well enough to be able to instruct a customer in
its safe use.
Safety is a matter of common sense...a matter of thinking before
acting. Most dealers have a list of specic good safety practices...
follow them.
The precautions listed in this Installation Manual are intended
as supplemental to existing practices. However, if there is a
direct conict between existing practices and the content of this
manual, the precautions listed here take precedence.
IMPORTANT NOTE TO THE SERVICER
Read this manual and familiarize yourself with the specic items
which must be adhered to before attempting to service this unit.
The precautions listed in this Installation Manual are intended
as supplemental to existing practices. However, if there is a
direct conict between existing practices and the content of this
manual, the precautions listed here take precedence.
RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION.
UNIT FEATURES
This unit has many features which are dierent than those found
on conventional PTAC units. The servicer must be familiar with
these features in order to properly service the unit.
• LCDI Power Cords - Underwriters Laboratories and the
National Electric Code (NEC) now require power cords that
sense current leakage and can open the electrical circuit
to the unit on units rated at 250 volts or less. In the event
that unit does not operate, check the reset button located
on or near the head of the power cord as part of the normal
troubleshooting procedure.
3
LCDI Power Cord
• Automatic 3-minute compressor lockout - After the
compressor cycles o, it will not restart for three minutes.
• Automatic 2nd stage electric heat - If the room
temperature falls to 4°F below the set point temperature,
the reverse cycle heat is shut o and the electric strip heat
is turned on.
• Automatic freeze protection - Whenever power is supplied
to the unit and the master switch is in the ON position,
automatic freeze protection is active. If the unit senses
temperature below 40°F, the fan motor and electric strip
heat are turned on. Freeze protection can be turned o, if
required.
• Random restart delay - To help eliminate power surges
after a power outage, the unit is equipped with a two to
four minute random restart delay feature. Whenever the
unit is plugged in with the master switch turned on and the
mode switch set in the cool or heat mode, a random restart
will occur. A random restart condition can be avoided by
setting the mode switch in the fan only or o position
before applying power to the unit.
• Fuse holder - On all 265 volt units, fuse holders are factory
installed. Check for blown fuse if unit does not operate.
Fuse holder is located behind the front. Replacement fuses
may be purchased from the Parts Department or contact
your sales representative for part numbers.
Control Panel
• Indication LEDs - The controal board has LEDs that indicate
board status and Error code. The LED is visible from the
top left of the unit when the front cover is remeoved.
Refer to the Error Table for LED status and Diagonostics.
• Load shedding - When input terminals have been congured
for load shedding operations. If at any time a switch is
closed between the IN1 and COM or IN2 and COM terminals
as congured, the compressor and electric heater will
lockout until the switch is opened.
• Transfer fan - The control board allows for an external
(transfer) fan connection.
• Front mounting hole - A mounting hole location is provided
to give the owner the option of securing the front to the
chassis. The mounting hole must be drilled at the dimple
indicating the correct location below a louver. The owner
must supply one 1/2 inch long #8 sheet metal screw per
unit. The screw must be removed before the front can be
removed.
Chassis Front
Front Mounting Screw accessed through louvers.
Goodman Part number Manufacturer's Part number Usage (ref)
A3410402 SLC015 15 AMP
A3410403 SLC020 20 AMP
A3410404 SLC025 25 AMP
A3410405 SLC030 30 AMP
Fuse Part Numbers
Product specificaties
Merk: | Amana |
Categorie: | Airco |
Model: | PTH093J25AXXX |
Heb je hulp nodig?
Als je hulp nodig hebt met Amana PTH093J25AXXX stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Amana
10 November 2024
10 November 2024
10 November 2024
10 November 2024
10 November 2024
10 November 2024
10 November 2024
10 November 2024
10 November 2024
14 Oktober 2024
Handleiding Airco
- Airco Electrolux
- Airco Bosch
- Airco Candy
- Airco Samsung
- Airco Delonghi
- Airco Panasonic
- Airco LG
- Airco AEG
- Airco Bauknecht
- Airco BEKO
- Airco Daewoo
- Airco Grundig
- Airco Honeywell
- Airco Inventum
- Airco Karcher
- Airco Medion
- Airco Remeha
- Airco Siemens
- Airco Toshiba
- Airco Unold
- Airco Vaillant
- Airco Whirlpool
- Airco Zanussi
- Airco Zibro
- Airco Adler
- Airco Airwell
- Airco Akai
- Airco Amcor
- Airco Apc
- Airco Arcelik
- Airco Argo
- Airco Balay
- Airco Bartscher
- Airco Bavaria
- Airco Be Cool
- Airco Bestron
- Airco Blaupunkt
- Airco Blumfeldt
- Airco Bodin
- Airco Bomann
- Airco Brandt
- Airco D-Let
- Airco Daikin
- Airco Daitsu
- Airco Defy
- Airco Dimplex
- Airco Dometic
- Airco Domo
- Airco Duracraft
- Airco Duux
- Airco Easy Home
- Airco Eco-De
- Airco Eden
- Airco Edgestar
- Airco Edy
- Airco Einhell
- Airco Emerio
- Airco Emerson
- Airco Eurom
- Airco Everglades
- Airco Evolar
- Airco Exquisit
- Airco Fairland
- Airco Ferroli
- Airco Finlux
- Airco Firstline
- Airco Fral
- Airco Frigidaire
- Airco Frilec
- Airco Fronius
- Airco Fuave
- Airco Fuji Electric
- Airco Fujitsu
- Airco G3 Ferrari
- Airco GE
- Airco General Electric
- Airco GlobalTronics
- Airco Gorenje
- Airco Gree
- Airco Gutfels
- Airco H.Koenig
- Airco Haier
- Airco Hisense
- Airco Hitachi
- Airco Holland Electro
- Airco Home Electric
- Airco Hotpoint
- Airco Hotpoint-Ariston
- Airco HQ
- Airco Hyundai
- Airco Iceberg
- Airco Innoliving
- Airco Insignia
- Airco Itho
- Airco Kalorik
- Airco Kelvinator
- Airco Kenmore
- Airco Klarstein
- Airco Koenic
- Airco Kogan
- Airco Korona
- Airco Lanaform
- Airco Lavorwash
- Airco Livington
- Airco Livoo
- Airco Logik
- Airco Maiko
- Airco Manta
- Airco Master
- Airco Maxicool
- Airco Meaco
- Airco Meireles
- Airco Melissa
- Airco Mesko
- Airco Mestic
- Airco Midea
- Airco Mistral
- Airco Mitsubishi
- Airco Moa
- Airco MPM
- Airco MundoClima
- Airco Nabo
- Airco Nedis
- Airco Philco
- Airco Prem-i-air
- Airco Primo
- Airco Princess
- Airco Profile
- Airco Progress
- Airco Proklima
- Airco Proline
- Airco Protector
- Airco Qlima
- Airco RCA
- Airco REMKO
- Airco Rotel
- Airco Rowenta
- Airco Royal Sovereign
- Airco Russell Hobbs
- Airco Sanyo
- Airco Sauber
- Airco Saunier Duval
- Airco Sencor
- Airco Sencys
- Airco Sharp
- Airco Sigma
- Airco SMC
- Airco Sonnenkonig
- Airco SPT
- Airco Starlyf
- Airco Stirling
- Airco Suntec
- Airco Tarrington House
- Airco Taurus
- Airco TCL
- Airco Team
- Airco Technisat
- Airco Teco
- Airco Tectro
- Airco Telefunken
- Airco Termozeta
- Airco Thomson
- Airco Tomado
- Airco Tosot
- Airco Toyotomi
- Airco Trilec
- Airco Tristar
- Airco Tronix
- Airco Trotec
- Airco Truma
- Airco Ufesa
- Airco Vestel
- Airco Vivax
- Airco Waeco
- Airco Westinghouse
- Airco White Knight
- Airco Whynter
- Airco Woods
- Airco Zelmer
- Airco Jocca
- Airco Jocel
- Airco Just Fire
- Airco OK
- Airco Olimpia Splendid
- Airco OneConcept
- Airco Oregon Scientific
- Airco Ozito
- Airco Becken
- Airco Black And Decker
- Airco Camry
- Airco Clatronic
- Airco Concept
- Airco ECG
- Airco Elba
- Airco Essentiel B
- Airco Guzzanti
- Airco Heinner
- Airco Khind
- Airco Orbegozo
- Airco Profilo
- Airco Trisa
- Airco Vox
- Airco Wilfa
- Airco Anslut
- Airco Kunft
- Airco Soler And Palau
- Airco Conrad
- Airco Ansonic
- Airco Aspes
- Airco Comfee
- Airco Corberó
- Airco Danby
- Airco Equator
- Airco Esatto
- Airco IFB
- Airco Infiniton
- Airco Koldfront
- Airco Listo
- Airco Orima
- Airco Svan
- Airco Ardes
- Airco Eldom
- Airco Teesa
- Airco Alpatec
- Airco ElectriQ
- Airco Heylo
- Airco HTW
- Airco Prime3
- Airco Avidsen
- Airco SereneLife
- Airco DCG
- Airco Kubo
- Airco Malmbergs
- Airco Challenge
- Airco Calor
- Airco Riffel
- Airco Broan
- Airco RIDGID
- Airco KDK
- Airco Bimar
- Airco Climadiff
- Airco Tripp Lite
- Airco Mabe
- Airco Equation
- Airco Godrej
- Airco Milectric
- Airco Orava
- Airco Simplicity
- Airco Cecotec
- Airco Baxi
- Airco Thermex
- Airco Keystone
- Airco Sanus
- Airco Carrier
- Airco Furrion
- Airco Rinnai
- Airco Carson
- Airco Artrom
- Airco Carrefour Home
- Airco Céliera
- Airco Commercial Cool
- Airco Coolix
- Airco Hokkaido
- Airco Kibernetik
- Airco Norpole
- Airco Senville
- Airco SHE
- Airco CyberPower
- Airco Perfect Aire
- Airco Be Quiet!
- Airco Ariston Thermo
- Airco Element
- Airco Dantherm
- Airco Argoclima
- Airco DEXP
- Airco Chigo
- Airco Elgin
- Airco Evapolar
- Airco EcoFlow
- Airco Liebert
- Airco Avalon Bay
- Airco NewAir
- Airco Braemar
- Airco ActronAir
- Airco Klimaire
- Airco Consul
- Airco SEEGER
- Airco LERAN
- Airco Friedrich
- Airco Aerian
- Airco Polocool
- Airco Convair
- Airco Companion
- Airco Volteno
- Airco Arcoaire
- Airco AFINTEK
- Airco Brivis
- Airco MRCOOL
- Airco B-Air
- Airco Monzana
- Airco Kaden
- Airco Geist
- Airco GoldAir
- Airco Avallon
- Airco Ravanson
- Airco Create
- Airco Columbia Vac
- Airco TURBRO
- Airco House & Luft
- Airco Daizuki
- Airco Bonaire
- Airco Evapcool
- Airco Vostok
- Airco American Comfort
- Airco Ocean Breeze
- Airco Quirky
- Airco Krone
- Airco KwiKool
- Airco Big Ass Fans
- Airco Arctic King
- Airco Omega Altise
- Airco Climachill
- Airco Heat Controller
- Airco Luma Comfort
- Airco AireMax
- Airco Kaco
- Airco Goodwe
- Airco Swegon
- Airco InAlto
- Airco JHS
- Airco FREONIC
- Airco ARCTIC WIND
- Airco Electroline
- Airco BLUEPALM
- Airco KuulAire
- Airco Cool-Space
- Airco BOSFOR
- Airco Aconatic
- Airco VänEE
- Airco Mayer
- Airco Yamazen
Nieuwste handleidingen voor Airco
12 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
10 November 2024
10 November 2024
10 November 2024
7 November 2024