Airpura G700DLX Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor Airpura G700DLX (2 pagina's) in de categorie Luchtreiniger. Deze handleiding was nuttig voor 2 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
To close the ī†¼lter chamber
Replace
the gasket
Position the
indentation in the cover
into the center of the
HEPA ī†¼lter
Replace
the 4 screws
and tighten
Turn the Airpura
back on casters
OPER ATING
&
FILTER REPLACEMENT
DIRECTIONS
G700
DLX
Insert the tube
into the ī†¼lter
chamber inside
the Preī†¼lter
Let the spiral
open to ī†¼ll
the opening
Open the top of the
spiral to make a
slight funnel
Insert the
Carbon canister into
the funnel and hold it
straight
Position the
Preī†¼lter inside
the ī†¼lter
chamber
Place a felt gasket at
the bottom of the
ī†¼lter chamber
Unfold the ī†¼lter slider
(Supplied with replacement
ī†¼lters or on request
Part#6F 001)
Roll it
into a spiral
Let the canister
slide down
theī†¼lter slider
Pull the ī†¼lter slider up
out of the cavity using
both hands and let the
canister slide to the
bottom of the cavity
Remove the ī†¼lter
slider and fold it
for further use
Slide in the
Hepa ī†¼lter
To open the ī†¼lter chamber
Turn over
the Airpura
Remove the 4
retaining screws
Take of f
the cover
Remove
the gasket
Odors, airborne
chemical control
26 lbs German Carbon Filter
13"H in x 13.25"OD in x 7"ID
Carbon Bed
3ā€ deep
Particle removal
HepaBarrier
Air Flow 635 cfm
More cfm than any other
home unit available
Preī†¼lter
570 in2 x 1 in
Housing
Powder coat steel
Poly Preī†¼lter 600 2-pack
12 months
26 lbs German Carbon Filter
24 months
Preī†¼lter Carbon
Alternates Cotton Preī†¼lter
TarBarrier Preī†¼lter
26 lbs anthracite Carbon ī†¼lter 100%
26 lbs coconut shell carbon ī†¼lter
Air puriī†¼ers models and ī†¼lter conī†¼gurations
Technical speciī†¼cations
Size
23 in x 15 in
Weight
45 lbs total
Watts
120 on high / 40 on low
Sound Level
30.2* db on low (at 6 feet)
63.0 db on high (635 cfm)
*at test conditions
HepaBarrier 600CT Filter
(95ā€‰% eī†¾cient @ 1 Microns)
12-16 months
3067330 60950
TO BEGIN USING YOUR
AIRPURA
Inspect the exterior of your Airpura to verify there is no damage from shipping.
If any damage is noted, please follow the instructions from the distributor returns
policy.
Wipe the unit with a damp cloth to remove any dust from packaging
Plug the unit into a regular grounded 110 volt outlet
Turn on the unit to MAX and allow it to run for at least 30 minutes
Set the variable speed control to the level you wish
The most eī†¾cient way to use your Airpura for regular air quality maintenance
is to run it at a low speed 24 hours a day 7 days a week.
Always maintain a humidity level of 40% in your home to ensure the
unit is operating at optimal levels. When using purifer with a
dehumidiī†¼er, please keep dehumidiī†¼er at least 6 feet away.
FILTER MAINTENANCE AND REPLACEMENT
The Preī†¼lter
Can be vacuumed from the exterior of the unit once a month or more often.
Should be replaced at least after 12 months of use
To vacuum the Preī†¼lter
Use the brush attachment on your vacuum cleaner
Vacuum slowly around the mesh surface of the ī†¼lter chamber
IMPORTANT SAFETY NOTE
Please ensure air puriī†¼er is turned OFF when plugging into a power source.
Failure to do so may result in motor potentially stalling and/or burning.
MaxMin
Off
1
MaxMin
Off
2
MaxMin
Off
3


Product specificaties

Merk: Airpura
Categorie: Luchtreiniger
Model: G700DLX

Heb je hulp nodig?

Als je hulp nodig hebt met Airpura G700DLX stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Luchtreiniger Airpura

Airpura

Airpura G700DLX Handleiding

22 Februari 2025
Airpura

Airpura F600 Handleiding

22 Februari 2025

Handleiding Luchtreiniger

Nieuwste handleidingen voor Luchtreiniger