READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOUR-
SELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
20" I-BEAM MOUNT FAN
20" (50.8 cm) MODEL 9520
OPERATING INSTRUCTIONS & PARTS MANUAL
DESCRIPTION
The Air King® 20" (50.8 cm) I-Beam mount fan features 3-speed pull cord
operation and a 3-paddle fan blade. This fan has a permanently lubricated
motor with a 9 ft. (2.74 m) 18/3 cord set and is constructed of sturdy,
powder coated steel.
SPECIFICATIONS
Motor ...................................... 120 V, 50/60 Hz
Blade diameter ........................ 20" (50.8 cm) Model 9520
Speeds .................................... 3
Control ..................................... Pull Cord
Air ow distribution .................. 360°
Approvals................................. UL/ETL Listed. Close mesh fan guard
meets OSHA requirements.....................
GENERAL SAFETY INFORMATION
1. Make certain that the power source conforms to the electrical
require
ments of the fan.
2. The power cord is equipped with a three-prong grounded plug that
must be inserted into a matching receptacle. Under no circumstances
should the grounding prong be cut off the plug. Where a two-prong wall
receptacle is encountered, it must be replaced with a properly grounded
three-prong receptacle installed in accordance with the National Electrical
Code (NEC) and all applicable local codes and ordinances. This work
must be done only by a qualied electrician, using copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS
NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE THE
RISK OF ELECTRICAL SHOCK. USE OF SUCH ADAPTERS IS NOT
PERMITTED IN CANADA.
3. Where possible, avoid the use of extension cords. If they must be used,
minimize the risk of overheating by ensuring that they are UL listed and
of the proper gauge and length. Never use a single extension cord to
operate more than one fan.
4. Do not insert ngers or foreign objects into the fan. Do not block or
tamper with the fan in any manner while it is in operation. Do not touch
the fan while in operation or just after it has been turned off, as some
parts may be hot enough to cause injury.
5. Unplug power cord before installing or servicing the fan.
WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE
SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR
SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.
6. This fan is intended for general use ONLY. It must NOT be used in
potentially dangerous locations such as î™­ammable, explosive, chemical
laden or wet atmospheres.
7. DO NOT mount fan near windows or bay doors. Rain may create an
electrical hazard.
8. Completely reassemble fan, according to instructions before
reconnecting to power supply.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE
THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE.
WARNING: THIS PLUG IS A SAFETY FEATURE, TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK AND PERSONAL INJURY. DO NOT REMOVE, REPLACE,
REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES
NOT FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE INCOR-
PORATED IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE CENTER
OR CALL 800-233-0268, MONDAY - FRIDAY, BETWEEN 8:00 A.M. AND 5:00
P.M. EST. IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED, CALL
THE TOLL FREE NUMBER FOR A REPLACEMENT LABEL.
MODEL
9520
SPEED
HIGH MED LOW
CFM 7510 5010 3735
M
3
/s 3.54 2.36 1.76
RPM 1560 1041 776
Amps 1.78 1.46 1.02
Watts 207 167 115
dB A 62 55 48
WARNING: BECAUSE OF SIZE AND WEIGHT OF THIS FAN, MAKE
SURE ALL PARTS ARE COMPLETELY ASSEMBLED ACCORDING TO
INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN FAN COMING
APART DURING OPERATION AND/OR PERSONAL INJURY.
I-BEAM MOUNT INSTALLATION
1. Locate the L-shaped pipe to the desired location on the I-Beam î™­ange.
Install the 5/16 x 2" U-Bolt over the pipe and through the clamping plate
holes. The at part of the clamping plate ts on the I-Beam ange and
the end with the slight bend goes against the pipe. Install î™­at washer,
lock washer and nuts. Finger tighten the nuts on the U-Bolt. (Figure 1)
2. Slide the clamping plate onto I-Beam î™­ange until U-Bolts contact
î™­ange.
3. Adjust L-shaped pipe so forward clamp plate is as close to the label
at the bend as possible.
4. Tighten nuts on bolt so pipe does not move.
5. Screw on the adapter mount as far as it will go on to the L-shaped
pipe. Tighten set screw in pipe coupling with provided allen key.
6. Align Yoke with grill mounting threads. Loosely attach one Grill Knob
and one Rubber Spacer to the Head Assembly. Attach the other Grill
Knob and Rubber Spacer to the Head Assembly and FIRMLY tighten.
Return to the rst Grill Knob and FIRMLY tighten. (Figure 2)
15084037Rev. A 9/07
5/16 Nut
5/16 Lock
Washer
5/16 Flat
Washer
1/4" Set Screw
Tighten
Bolt
Yoke
Fan Head
Figure 1
U-Bolts
Tighten Clamp
Plate Here
9. This Fan is not suitable for use in hazardous locations. Please refer to
National Electric Code (NEC) Article 500 or applicable state or local
codes or standards relating to electrical requirements for Hazardous
locations. THIS FAN DOES NOT MEET THE REQUIRMENTS OF
NEC ARTICLE 500 (2002).
Commerical Style Fan
WARNING: This fan should be used only in a clean, dry
environment. Mounting of this product in any way other then
specied in the instruction sheet will null and void the
manufacturer's warranty.
MODEL 9520
5084037Rev. A 9/07 2
Secondary
Support
Cable
Figure 4
OPERATION
1. Plug in cord and select desired operating speed with pull cord.
2. WARNING: This fan should be used only in a clean, dry environment. Mounting
of this product in any way other then specied in the instruction sheet will null
and void the manufacturer's warranty.
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD BEFORE SERVICING.
CLEANING: Use a soft cloth and a mild soap solution such as liquid dish
washing detergent.
CAUTION: DO NOT USE GASOLINE, BENZINE, THINNER, HARSH
CLEANERS, ETC. WHICH WILL DAMAGE THE FAN.
Dry all parts with a soft cloth completely before reconnecting to power supply.
STORAGE: When not in use, keep unit in a clean dry place.
MOTOR IS PERMANENTLY LUBRICATED.
CAUTION: THE SECONDARY SUPPORT CABLE PROVIDED
SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED
OVERHEAD FOR ADDITIONAL SAFETY.
SECONDARY SUPPORT CABLE
1. Loop one end of Cable around the Large Diameter Wires of both the
Front and Rear Circulator Guard. (Figure 4)
2. Attach a Cable Clamp with the "U" on the tail side of the loop leaving
a tail approximately 1 to 2 inches. Tighten Clamp Nuts. Make sure no
part of the Cable interferes with the Blade. (Figure 4)
3. Wrap the other end of the Cable around a secure building joist, truss,
I-Beam or other support near the Fan. Do not attach cable to I-Beam
mount pipe. Take up all excess slack in the Cable. (Figure 3)
CAUTION: USE ONLY THE MOUNTING HARDWARE WHICH IS
RECOMMENDED FOR USE ON THIS FAN.
4. Attach the remaining Cable Clamp as indicated in . The excess Step 2
tail should be trimmed to extend 1 to 2 inches past the Clamp.
5. Check the Assembly to assure the Blade is free of all obstructions.
CAUTION: USE OF THE SECONDARY SUPPORT CABLE DOES NOT
GUARANTEE PROTECTION AGAINST INJURY OF PERSONS. MOUNT-
ING OF BOTH THE CIRCULATOR AND CABLE COULD FAIL IF SUB-
JECTED TO ABUSE, NEGLECT OR IMPROPER INSTALLATION.
Figure 3
Large Guard
Wires
Yoke Rubber
Spacer
Figure 2
PART BAG
Description Qty.
5/16 x 2" U-Bolt 2
Clamp Plate 2
5/16-13 Nut 4
5/16 Lock Washer 4
5/16 Flat Washer 4
Rubber Spacer 2
Grill Knob 2
Set Screw 1/4-20 1
Secondary Support Kit 1
Allen Key 1
LIMITED WARRANTY
WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials.
HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date of
original purchase or until the original purchaser of the product sells or transfers the product, whichever rst occurs.
WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or
replace the whole product with the same or comparable model.
WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed because of accident, improper handling
or operation, shipping damage, abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of
products to Air King for repair or replacement. Air King will pay return shipping charges from Air King following warranty repairs or replacement
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY),
LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS
THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING'S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY
INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY
HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL AIR
KING'S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH
LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these
exclusions or limitations may not apply to you. This warranty gives you specic legal rights. You may also have other rights which vary from state to state and province to
province. Proof of purchase is required before a warranty claim will be accepted.
CUSTOMER SERVICE:
Toll-Free (800) 233-0268. Email: producthelp@laskoproducts.com
Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be
reached Monday through Friday, 8am-5pm Eastern. Please have your model number available, as well as the type and style (located on the
underside of your product). Please do not return product to place of purchase.
Customer Service Dept., 820 Lincoln Ave., West Chester, PA 19380 (Please do not send product to this location) www.laskoproducts.com
PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY
REASONS, MANY ELECTRONIC COMPONENTS AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS
FOR INSTALLATION OR REPLACEMENT.


Product specificaties

Merk: Air King
Categorie: Ventilator
Model: 9520

Heb je hulp nodig?

Als je hulp nodig hebt met Air King 9520 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Air King

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator