Air King 9236D Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Air King 9236D (8 pagina's) in de categorie Ventilator. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
3032730 Rev. E 10-17 1 of 8
Drum Fan
Models: 9236D, 9936D, 9942D,
9236C, 9936C, 9942C
Read all instructions before using this Fan.
IMPORTANT SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed
to reduce the risk of fire, electrical shock and injury to persons, including the following:
DO NOT use this fan to ventilate areas where flammable liquids or vapors are used, stored or are present, including paints,
gasoline, varnishes, floor refinishing products or solvents. ALWAYS read and follow all warnings and instructions on the
containers for these products!
ALWAYS be sure the plug fits tightly into the outlet. When plugs fit loosely into outlets, they may slip partially out of the outlet
and create a poor connection. This may cause outlets to overheat and create a potential fire hazard. Outlets in this condition
should be replaced by a qualified electrician.
ALWAYS unplug the power cord when servicing, cleaning or moving the Fan. DO NOT use the ON/OFF switch as the sole means
of disconnecting power. NEVER leave children unattended when the Fan is on or plugged in. ALWAYS turn off and unplug the
Fan when not in use.
BE CERTAIN that the power source for the Fan is 120V AC. DO NOT plug the Fan into 240V or other power source.
The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no
circumstances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be
replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and
all applicable local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only.
DISCARD PRODUCT IF THE ATTACHMENT PLUG IS DAMAGED. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL
INJURY, DO NOT REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES NOT
FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS PLUG.
REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK - DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES.
DO NOT USE A THREE-PRONG TO TWO-PRONG ADAPTER. IMPROPER CONNECTION MAY CREATE THE RISK OF
ELECTRICAL SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING
OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.
REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK - DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED
CONTROL DEVICES.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR PERSONAL INJURY, ALWAYS
FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS AND WARNINGS:
AVOID the use of extension cords, power strips, power taps, outlet style air fresheners or other cord connected device, as these devices
may overheat and cause a fire hazard.
DO NOT route power cord under rugs, carpets, runners or furniture. This may damage the cord or cause it to overheat creating a fire hazard.
ALWAYS place the Fan on a stable, flat, level surface while in operation to prevent the Fan from overturning.
NEVER insert or allow fingers or objects to enter grill openings while Fan is in operation or injury and/or damage to the Fan may occur.
DO NOT block, cover or obstruct air flow to or from the fan while in operation.
DO NOT use this Fan outdoors or near water or wet locations such as a bath tub, pool or hot tub. Use of this Fan in a wet location may
create a shock hazard.
DO NOT route power cord in or through areas such as doorways or where the cord may be damaged or create a tripping hazard.
NEVER use a single extension cord to operate more than one Fan or other electrical device.
DO NOT use this Fan in a window. Rain may create an electrical hazard.
DO NOT use this Fan if it has been damaged or is not functioning properly.
THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).This Fan is not suitable for use in agricultural facilities
including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7 (2008), or
applicable state or local codes or standards relating to electrical requirements for agricultural buildings.
THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).This Fan is not suitable for use in hazardous locations.
Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical requirements
for hazardous locations.
WARNING
WARNING
CAUTION
IMPORTANT INSTRUCTIONS - OPERATING MANUAL
OPERATING INSTRUCTIONS
SECTION 1
Operation
WARNING: THIS FAN SHOULD BE USED ONLY IN A CLEAN, DRY ENVIRONMENT.
MOUNTING OF THIS PRODUCT OR USE IN ANY WAY OTHER THAN SPECIFIED IN THE
INSTRUCTION SHEET WILL NULL AND VOID THE MANUFACTURERS WARRANTY.
1. Carefully unpack fan from the carton and place on a firm, level surface.
2. Plug cord into a properly grounded three-prong 120 V outlet and select the desired speed
setting from the control switch located on the side of the fan (Figure 1).
WARNING: DO NOT EXPOSE TO WATER OR RAIN.
www.airkinglimited.com
3032730 Rev. E 10-17 2 of 8
SECTION 2
Use and Care
WARNING: MAKE SURE FAN IS UNPLUGGED BEFORE STARTING INSTALLATION
OR SERVICING.
1. Cleaning the Fan: Use a mild detergent, such as dishwashing liquid, and dry with a soft
cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry all parts
before reconnecting to power supply. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
2. If fan guards have been removed for any reason, reinstall before reconnecting to power
source or operating fan.
CAUTION: DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANERS, ETC.
WHICH WILL DAMAGE THE FAN.
3. Storage: When not in use, keep fan in a clean dry place.
MOTOR IS PERMANENTLY LUBRICATED.
Troubleshooting Guide
Trouble Probable Cause Suggested Remedy
1. Fan does not operate. 1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker.
1b. Fan is not plugged in. 1b. Plug fan into a properly grounded three-prong outlet.
1c. A speed has not been selected. 1c. Using the switch on the fan’s controls, select a speed.
1d. Motor has stopped operating 1d. Call your dealer for service.
2. Fan is making rattling noise. 2a. Grill is loose. 2a. Unplug fan and check to make sure all bolts holding grill in place
are secure.
2b. Wheels are loose. 2b. Unplug fan and check to make sure wheel bolts are secure.
LIMITED WARRANTY
(Valid in the USA, its Territories, and CANADA Only)
WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials.
HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date of original purchase or until the original
purchaser of the product sells or transfers the product, whichever first occurs.
WHAT Air King WILL DO: Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model. For
all warranty claims, the product must be returned to Air King America, LLC at customer expense with proof of purchase within the warranty period. Contact the Air King customer service
department to obtain a Return Authorization (“RA”). DO NOT return products without an RA or the warranty claim will not be processed.
WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, shipping damage,
abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or replacement. Air King will pay return
shipping charges from Air King following warranty repairs or replacement.
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE OF
ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL Air King’S
LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR
OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL Air King’S LIABILITY UNDER ANY EXPRESS OR
IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these exclusions or
limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to province.
Proof of purchase is required before a warranty claim will be accepted.
CUSTOMER SERVICE:
Toll-Free (800) 233-0268
Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through Friday, 8am-4pm Eastern.
Please have your model number available, as well as the type and style (located on the label inside of your product).
Please do not return product to place of purchase.
www.airkinglimited.com
PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS AND MOST
HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.
Figure 1
H
I
O
F
F
L
O
W
www.airkinglimited.com
3032730 Rev. E 10-17 3 of 8
REPLACEMENT PARTS DIAGRAM
Models 9942D, 9942C
# Qty. Description Replacement Part #
1 2 Name Plate 02084613
2 24 Grill Screw with Washer 3032909
3 2 Grill 5097184BK
4 1 Blade 3032416
5 1 Set Screw 05090012
6 1 Motor 03032105
7 1 Drum 3032670
8 4 3032911Nut with Washer
9 2 Wheel Cap 3032921
10 1 Wheel Shaft 03032162
11 2 Wheel 03032171
12 2 Rubber Feet 03032170
13 1 Extension Bar 3032144
14 4 Screw 3032905
15 4 Nut 3032911
16 1 Power Cord/Strain Relief (US) 03032127
1 Power Cord/Strain Relief (Canada) 03032129
17 1 Switch 3032115
18 1 Belt 3032953
19 1 Large Pulley 3032951
20 1 03032124Belt Shaft Assembly
21 1 Small Pulley 3032950
22 1 Set Screw 5090075
1
2
3
910 11
5
4
7
8
17
6
16
13
12
3
2
18
19
22
21
20
Models 9936D, 9936C
# Qty. Description Replacement Part #
1 2 Name Plate 02084613
2 24 Grill Screw with Washer 3032909
3 2 Grill 03032183
4 1 Blade 3032413
5 1 Set Screw 05090012
6 1 Motor 03032105
7 1 Drum 3032660
8 4 3032911Nut with Washer
9 2 Wheel Cap 3032921
10 1 Wheel Shaft 03032162
11 2 Wheel 03032171
12 2 Rubber Feet 03032170
13 1 Extension Bar 3032144
14 4 Screw 3032905
15 4 Nut 3032911
16 1 Power Cord/Strain Relief (US) 03032127
1 Power Cord/Strain Relief (Canada) 03032129
17 1 Switch 3032115
18 1 Belt 3032953
19 1 Large Pulley 3032951
20 1 03032124Belt Shaft Assembly
21 1 Small Pulley 3032950
22 1 Set Screw 5090075
15
14


Product specificaties

Merk: Air King
Categorie: Ventilator
Model: 9236D

Heb je hulp nodig?

Als je hulp nodig hebt met Air King 9236D stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Air King

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator

Livoo

Livoo DOM510 Handleiding

20 December 2024
Orava

Orava SF-13 Handleiding

18 December 2024
EMOS

EMOS P56PR2 Handleiding

14 December 2024
Midea

Midea FTS30-13AR Handleiding

14 December 2024
Midea

Midea FTS35-9AR Handleiding

14 December 2024
Midea

Midea FTS30-9AR Handleiding

14 December 2024