IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical
requirements of the Fan.
3. Use this Fan only as described in this manual. Any other use not
recommended by the manufacturer may cause re, electrical shock,
or injury to persons.
4. To reduce the risk of personal injury and electric shock, the Fan
should not be played with or placed where small children can
reach it.
5. Unplug power cord before servicing, or moving the Fan.
WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH
AS THE SOLE MEANS OF DISCONNECTING POWER WHEN
INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE
POWER CORD.
6. This Fan must NOT be used in potentially dangerous lo-
cations such as ammable, explosive, chemical-laden or
wet atmospheres.
7. DO NOT use Fan in or near a window. Rain may create an
electrical hazard.
8. Completely reassemble Fan, according to instructions, before
reconnecting to power supply.
9. The power cord is equipped with a three-prong grounded plug
that must be inserted into a matching receptacle. Under no
circumstances should the grounding prong be cut off the plug.
Where a two-prong wall receptacle is encountered, it must
be replaced with a properly grounded three-prong receptacle
installed in accordance with the National Electrical Code (NEC)
and all applicable local codes and ordinances. This work must
be done only by a qualied electrician, using copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG
ADAPTER IS NOT RECOMMENDED. IMPROPER CONNECTION
MAY CREATE THE RISK OF ELECTROCUTION. USE OF SUCH
ADAPTERS IS NOT PERMITTED IN CANADA.
10. Where possible, avoid the use of extension cords. If they must
be used, minimize the risk of overheating by ensuring that they
are UL listed. Never use a single extension cord to operate more
than one Fan.
11. Do not operate any Fan with a damaged cord or plug or after the
Fan malfunctions, has been dropped or damaged in any manner.
Return Fan to authorized service facility for examination, electrical
or mechanical adjustment or repair.
12. Do not insert or allow ngers or foreign objects to enter any
ventilation or exhaust opening as it may cause an electric shock
or re, or damage the Fan. Do not block or tamper with the Fan
in any manner while it is in operation.
13.Locate the Power Cord so the Fan or other objects are not resting
on it. Do not run Power Cord under carpeting. Do not cover Power
Cord with throw rugs, runners, or the like. Arrange Power Cord
away from room trafc and where it will not be tripped over.
14.This Fan is not intended for use in wet or damp locations.
Never locate a Fan where it may fall into a bathtub or other
water container.
15. Do not use Fan outdoors.
16.This Fan is not suitable for use in hazardous locations. Please
refer to National Electric Code (NEC) Article 500 or applicable
state or local codes or standards relating to electrical requirements
for Hazardous locations. THIS FAN DOES NOT MEET THE
REQUIRMENTS OF NEC ARTICLE 500 (2002).
WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED
CONTROL DEVICES.
CAUTION: BECAUSE OF THE SIZE AND WEIGHT OF THIS
FAN, MAKE SURE ALL PARTS ARE COMPLETELY ASSEMBLED
ACCORDING TO INSTRUCTIONS. FAILURE TO DO SO COULD
RESULT IN FAN COMING APART DURING OPERATION AND/OR
PERSONAL INJURY.
24" / 30" OSCILLATING WALL MOUNT FAN
MODEL 9025, 9035, 9074, 9075
24" / 30" NON-OSCILLATING WALL MOUNT FAN
MODEL 9024, 9030, 9070, 9071
4Rev. A 9/07 5084414
1Rev. A 9/07 5084414
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING.
WARNING: DO NOT IMMERSE FAN IN WATER!
CLEANING: Use a soft cloth and mild soap solution such as liquid dish washing detergent. Dry all parts completely before reconnecting to
power supply.
CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners, etc. as they will damage the Fan. NEVER use
ALCOHOL OR SOLVENTS.
SERVICING: All other servicing, with the exception of general user maintenance, should be performed by an authorized service representative. Call
1-800-233-0268, Monday through Friday, between the hours of 8:00 a.m.and 5:00 p.m. EST for the location of your nearest service center.
LUBRICATION: Precision bearings are sealed at the factory for life and do not require further lubrication.
STORAGE: Store the Fan, with these instructions, in a clean and dry place.
GENERAL SAFETY INFORMATION
When using electrical appliances,
basic precautions should always be followed
to reduce the risk of re, electric shock and injury to person,
including the following:
FOR OSCILLATING MODELS:
3. Push down oscillation knob on motor OSCILLATION:
housing to make fan head move from side to side.
NOTE FOR OSCILLATING MODELS: FAN IS SHIPPED
WITH 90º OSCILLATION ANGLE. FOR 45º OSCILLATION
ANGLE, CONNECT THE OSCILLATION LINK TO THE INNER-
MOST HOLE IN THE CAM GEAR. (Inset A)
1.
2.
3.
(Inset A)
Cam Gear
90˚
45˚
IMPORTANT INSTRUCTIONS - OPERATING MANUAL
SAVE THESE INSTRUCTIONS
LIMITED WARRANTY
WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials.
HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date of original
purchase or until the original purchaser of the product sells or transfers the product, whichever rst occurs.
WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace
the whole product with the same or comparable model.
WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed because of accident, improper handling or
operation, shipping damage, abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to
Air King for repair or replacement. Air King will pay return shipping charges from Air King following warranty repairs or replacement
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY),
LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS
THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING'S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY
INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY HOUSE
FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL AIR KING'S LIABILITY
UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE
UPON THE EXPIRATION OF THE WARRANTY PERIOD.
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages,
so these exclusions or limitations may not apply to you. This warranty gives you specic legal rights. You may also have other rights which vary from state to
state and province to province. Proof of purchase is required before a warranty claim will be accepted.
CUSTOMER SERVICE:
Toll-Free (800) 233-0268. Email: producthelp@laskoproducts.com
Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday
through Friday, 8am-5pm Eastern. Please have your model number available, as well as the type and style (located on the underside of your product). Please
do not return product to place of purchase.
Customer Service Dept., 820 Lincoln Ave., West Chester, PA 19380 (Please do not send product to this location)
www.laskoproducts.com
PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC
COMPONENTS AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.
IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL
2Rev. A 9/07 5084414 3Rev. A 9/07 5084414
GRILL AND BLADE ASSEMBLY (Figures 5 and 6)
NOTE: The assembly of the blade and grill is identical, regardless if the Fan has an oscillating motor or a non-oscil-
lating motor.
1. Install the onto the , lining up the six holes in the grill with the six threaded holes in the . Install (6) 10-32 X 5/16" Rear Grill Motor Motor
Hex Screws through the into the . Securely tighten all (6) screws.Rear Grill Motor (Figure 5)
2. Push the onto the , centering the Hub facing away from the motor, until it stops against the shaft . Align Fan Blade Motor Shaft (Inset A)
Square Head Bolt with at of the Motor Shaft. TIGHTEN VERY SECURELY WITH AN ADJUSTABLE WRENCH. Failure to securely tighten
the Bolt could result in damage to the Fan and/or personal injury.
3. Hold the Front Grill so that the name, in the center, is right side up and straight across. Starting at the top: Fasten Front Grill to Rear Grill
by sliding the hooked wires on the Front Grill over the outermost ring on the Rear Grill. (Figure 6 / Detail A). The bottom most hooks will
OPERATING INSTRUCTIONS
1. TO OPERATE: Plug cord into a grounded 120V, 60 Hz outlet. Select desired operating speed with pull cord on the rear of the motor:
First pull: High Second pull: Medium
Third pull: Low Fourth pull: OFF NOTE: THIS FAN IS VERY HEAVY.
Failure to securely hold onto head assembly while adjusting head angle
could result in personal injury.
2. TO ADJUST HEAD ANGLE: While holding head rmly, loosen knob under motor (turn counterclockwise). Tilt head to desired position
FIRMLY retighten knob under motor.
NOTE: Motor Head Adjustment Knob and the On/Off Pull Cord have the same location on oscillating or non-oscillating models.
CAUTION: THE SECONDARY SUPPORT CABLE
PROVIDED SHOULD BE USED ANYTIME THE
CIRCULATOR IS MOUNTED OVERHEAD FOR
ADDITIONAL SAFETY.
SECONDARY SUPPORT CABLE (Figures 7 and 8)
1. Loop one end of Cable around the Large Guard Wires of both the Front and Rear
Grills.
2. Attach a Cable Clamp with the "U" on the tail side of the loop leaving a tail
approximately 1 to 2 inches. Tighten Clamp Nuts. Make sure no part of the Cable
interferes with the Blade.
3. Wrap the other end of the Cable around a secure building joist, truss, or other sup-
port near the Fan. Take up all excess slack in the Cable.
CAUTION: USE ONLY THE MOUNTING HARDWARE WHICH
IS RECOMMENDED FOR USE ON THIS FAN.
4. Attach the remaining Cable Clamp as indicated in Step 2. The excess tail should be
trimmed to extend 1 to 2 inches past the Clamp.
5. Check the Assembly to assure the Blade is free of all obstructions.
CAUTION: Use of the secondary support cable does not guarantee
protection against injury of persons, mounting of both the circulator and
cable could fail if subjected to abuse, neglect or improper installation.
WALL BRACKET INSTALLATION (Figures 1 through 4)
NOTE: Always install the bracket to a minimum of 2" x 4" studding.
1. Insert the 7/16-14 x 3-1/2" Bolt through Flag Bracket, Wall Bracket and into the 7/16-14 Lock Nut. Tighten with Adjustable Wrenches. MAKE
CERTAIN THE DIRECTION OF THE FLAG BRACKET is as shown in . Figure 1
2. THE HARDWARE TO ATTACH THE WALL BRACKET TO THE WALL STUD IS NOT SUPPLIED. Locate the wall stud nearest to the desired
Fan location. Attach the Wall Bracket to the stud using (3) 5/16" diameter x 2" long Lag Screws.
3. Position the in the Flag Bracket Motor Neck and align the Pivot Hole with the Larger Hole in the Flag Bracket. (Figure 2)
4. Attach pull string to motor speed switch, if desired.
5. Insert the 1/2" X 1" Hex Bolt (3/4" head) through the Motor Neck, and the Flag Bracket. Place 1/2" diameter Split Lockwasher then the 1/2"
diameter Hex Nut (3/4" head) and tighten fully with 2 adjustable wrenches. (Figure 3)
6. From the same side of the Motor Neck,insert one 1/4-20 X 1 5/8" Carriage Bolt through the Arc-Shaped Slot in the Motor Neck and Hole in
the Flag Bracket. (Figure 3)
To Fasten: Place one 1/4" Flatwasher, one 1/4" Internal Tooth Lockwasher, a second 1/4" Flatwasher and then tighten the Adjustable Knob
over the remaining threads. Final assembly of the Motor to the Wall Mount Bracket is illustrated in Figure 4.
Figure 1
Detailed View of Hardware
Figure 2
Figure 3 Figure 4
Wall Bracket
7/16-14 X 3 1/2" Bolt
Flag Bracket
Figure 8
Large Guard
Wires
Figure 7
require the use of a athead screwdriver to complete assembly. Stand behind the Fan. Slip the at of the screwdriver between the Front
and Rear Grills, next to one of the unfastened hooks. (Figure 6 / Detail B) Pull screwdriver handle upwards towards the Rear Grill. Slip the
Front Grill hook over the Rear Grill outer ring with a push. Repeat procedure with remaining hooks.
CAUTION: DO NOT BEND WIRES ON THE FRONT OR THE REAR GRILLS.
Figure 5
Inset A
Non-Oscillating Motor Shown
Detail B
Bottom Hooks
Detail A
Top Hooks
Non-Oscillating Motor Shown
Figure 6
7/16-14 Lock Nut
Non-Oscillating Motor Shown
Placement of Motor to
Flag Bracket
Oscillating Motor Shown
Final Assembly of Motor to
Wall Mount Bracket Secondary
Support
Cable
Wall Mount Assembly
Motor Neck


Product specificaties

Merk: Air King
Categorie: Ventilator
Model: 9025

Heb je hulp nodig?

Als je hulp nodig hebt met Air King 9025 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Air King

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator

Livoo

Livoo DOM510 Handleiding

20 December 2024
Orava

Orava SF-13 Handleiding

18 December 2024
EMOS

EMOS P56PR2 Handleiding

14 December 2024
Midea

Midea FTS30-13AR Handleiding

14 December 2024
Midea

Midea FTS35-9AR Handleiding

14 December 2024
Midea

Midea FTS30-9AR Handleiding

14 December 2024