Aim TTi EX354RD Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Aim TTi EX354RD (30 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 19 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/30
EX354RD & EX354RT
Bench Power Supplies
INSTRUCTION MANUAL
1
Table of Contents
Introduction 2
Specification 2
Safety 4
Installation 5
Connections 5
Operation - Main Outputs 6
Operation - Auxiliary Output 7
Operation General- 7
Maintenance 8
Instructions en Francais
Sécurité 9
Installation 10
Connexions 10
Fonctionnement - Sorties principales 11
Fonctionnement 12– S ortie Auxiliaire
Fonctionnement Généralités 12-
Maintenance 13
Bedienungsanleitung auf Deutsch
Sicherheit 14
Installation 15
Anschlüsse 15
Betrieb Hauptausgänge 15-
Betrieb Hilfsausgang 17
Betrieb - Allgemein 17
Wartung 18
I struzioni in Italiano
Sicurezza 19
Installazione 20
Collegamenti 20
Funzionamento 20- Uscite principali
Funzionamento 22 Uscita Ausiliaria
Funzionamento enerale 22- G
Manutenzione 23
Instrucciones en Español
Seguridad 24
Instalación 25
Conexiones 25
Operación 25- Salidas Principales
Operación 27 Salida Auxiliar
Operación General 27-
Mantenimiento 28
2
Introduction
The EX354RD and EX354RT provide high levels of power (up to 305 watts) in a compact and
attractive case style.
High resolution controls allow precise setting of voltage and current levels which are indicated on
accurate and legible digital meters.
Excellent line and load regulation are matched by low noise and good transient response. High
power efficiency ensures that the unit remains cool without any fan noise. Remote sense
terminals are provided so that good regulation can be maintained across remote loads at high
current.
The EX354RD has two independent and isolated outputs each with a 0 to 35V, 0 to 4A capability.
The outputs operate in constant voltage or constant current mode with automatic cross over and -
mode indication. Each output has its own on off switch. Where higher voltages or currents are -
required the outputs can be wired in either series or parallel to provide voltages up to 70 volts or
currents up to 8 Amps.
The EX354RT has, in addition, an Auxiliary ‘logic voltage’ output with a 5A current capability. To
reflect the increasing usage of low voltage logic devices, this output can be preset between -
1.5 volts and 5 volts via a front panel control.
The total power capability is 280 watts for the dual supply and 305 watts for the triple.
The EX orporates separate digital voltage and current meters on each main output. -R series inc
The meters use bright 14mm (0·56”) LED displays and have an update rate of 4 per second
providing near instantaneous response. Simultaneous metering of voltage and current provides
accurate information “at a glance” and avoids any possibility of misinterpretation. When an output
switch is set to “off”, the current limit setting is displayed enabling conditions to be set before the
load is connected. With the right hand main output off, the right hand meters can be used to - -
momentarily display the preset Auxiliary voltage and current limit.
The EX R series has been designed to meet the stringent requirements of relevant IEC -
standards for safety and EMC, including harmonics emissions. All outputs are intrinsically short
circuit proof, and are protected against external voltages and reverse currents.
Specification
MAIN OUTPUTS
Voltage Range:
0V to 35V minimum.
Current Range:
0A to 4A minimum.
Output Voltage Setting:
By coarse and fine controls.
Output Current Setting:
By single logarithmic control.
Operating Mode:
Constant voltage or constant current with automatic cross-over.
Output Switch:
Electronic. Preset voltage and current displayed when off.
Output Terminals:
Universal 4mm safety binding posts on 19mm (0.75”) pitch.
Sensing: Switchable between local and remote. Spring loaded push terminals -
for remote connection.
Output Protection: Output will withstand up to 40V forward voltage.
Reverse protection by diode clamp for reverse currents up to 3A.
Load Regulation:
<0.01% of maximum output for 90% load change, using remote sense.
Line Regulation:
<0.01% of maximum output for 10% line change.


Product specificaties

Merk: Aim TTi
Categorie: Niet gecategoriseerd
Model: EX354RD

Heb je hulp nodig?

Als je hulp nodig hebt met Aim TTi EX354RD stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Aim TTi

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd