AIC XD1100-1102 Handleiding
AIC
Disk array
XD1100-1102
Lees hieronder de 📖 handleiding in het Nederlandse voor AIC XD1100-1102 (72 pagina's) in de categorie Disk array. Deze handleiding was nuttig voor 65 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/72
Model
SSG-DR
SSG-DR
Documen
t
Date
Version
FC41-1102
-
SA11-1102
-
t
XM-UG-
A
02/09/20
1
1.05
X
1U
1
De
s
-
A1 FC
/
-
A1 SA
S
A
-XD1100-11
1
0
Stora
g
e
X
D1
1
1
0-
B
Use
r
s
cription
/
SAS to SA
S
S
to SAS/S
A
0
Solution
G
1
00 S
e
B
ay
R
r
’s Man
u
S
/SATA 1U
A
TA 1U10
S
G
roup
e
ries
R
B
O
u
al
10 Single E
x
S
ingle Expa
n
O
D
x
pander RB
O
n
der RBOD
O
D
1U10 RBOD User’s Manual
Copyright© 2010 Advanced Industrial Computer, Inc. Page 2 of 72
All Rights Reserved. Rev.1.05
Copyright
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any
form or by any means, electronic, mechanical, photo-static, recording or otherwise, without the
prior written consent of the manufacturer.
Trademarks
All products and trade names used in this document are trademarks or registered trademarks of
their respective holders.
Changes
The material in this document is for information purposes only and is subject to change without
notice.
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Warning:
• A shielded-type power cord is required in order to meet FCC emission limits and also to
prevent interference to the nearby radio and television reception. It is essential that only
the supplied power cord be used.
• Use only shielded cables to connect I/O devices to this equipment.
• You are cautioned that changes or modifications not expressly approved by the party
responsible for compliance could void your authority to operate the equipment.
Disclaimer:
Advanced Industrial Computer shall not be liable for technical or editorial errors or omissions
contained herein. The information provided is provided "as is" without warranty of any kind. To
the extent permitted by law, neither AIC or its affiliates, subcontractors or suppliers will be liable
for incidental, special or consequential damages including downtime cost; lost profits; damages
relating to the procurement of substitute products or services; or damages for loss of data, or
software restoration. The information in this document is
subject to change without notice.
1U10 RBOD User’s Manual
Copyright© 2010 Advanced Industrial Computer, Inc. Page 3 of 72
All Rights Reserved. Rev.1.05
SAFETY PRECAUTIONS
Before getting started, please read the following important cautions:
• All cautions and warnings on the equipment or in the manuals should be noted.
• Most electronic components are sensitive to electrical static discharge, therefore, be sure to ground
yourself at all times when installing the internal components.
• Use a grounding wrist strap and place all electronic components in static-shielded devices. Grounding
wrist straps can be purchased in any electronic supply store.
• Be sure to turn off the power and then disconnect the power cords from your system before performing
any installation or servicing. A sudden surge of power could damage sensitive electronic components.
• Do not open the system’s top cover. If opening the cover for maintenance is a must, only a trained
technician should do so. Integrated circuits on computer boards are sensitive to static electricity. Before
handling a board or integrated circuit, touch an unpainted portion of the system unit chassis for a few
seconds. This will help to discharge any static electricity on your body.
• Place this equipment on a reliable surface when install. A drop or fall could cause injury.
• Please keep this equipment from away humidity.
• Carefully mount the equipment into the rack, in such manner, that it won’t be hazardous due to uneven
mechanical loading.
• Do not leave this equipment in an environment unconditioned, out of operation or storage temperature
range may damage the equipment.
• This equipment is to be installed for operation in an environment with maximum ambient temperature
below 35°C.
• The openings on the enclosure are for air convection to protect the equipment from overheating. DO
NOT COVER THE OPENINGS.
• Never pour any liquid into ventilation openings. This could cause fire or electrical shock.
• Make sure the voltage of the power source is within the specification on the label when connecting the
equipment to the power outlet. The current load and output power of loads shall be within the
specification.
• This equipment must be connected to reliable grounding before using. Pay special attention to power
supplied other than direct connections, e.g. using of power strips.
• Place the power cord out of the way of foot traffic. Do not place anything over the power cord. The
power cord must be rated for the product, voltage and current marked on the product’s electrical ratings
label. The voltage and current rating of the cord should be greater than the voltage and current rating
marked on the product.
• If the equipment is not used for a long time, disconnect the equipment from mains to avoid being
damaged by transient over-voltage.
• Never open the equipment. For safety reasons, only qualified service personnel should open the
equipment.
• If one of the following situations arise, the equipment should be checked by service personnel:
¾ The power cord or plug is damaged.
¾ Liquid has penetrated the equipment.
¾ The equipment has been exposed to moisture.
¾ The equipment does not work well or will not work according to its user manual.
¾ The equipment has been dropped and/or damaged.
¾ The equipment has obvious signs of breakage.
¾ Please disconnect this equipment from the AC outlet before cleaning. Do not use liquid or detergent
for cleaning. The use of a moisture sheet or cloth is recommended for cleaning.
Product features and specifications are subject to change without notice.
Product specificaties
Merk: | AIC |
Categorie: | Disk array |
Model: | XD1100-1102 |
Gewicht: | 15500 g |
Stroomvoorziening: | 100 - 240VAC |
Frequentie van processor: | 553 MHz |
Vormfactor: | SFF |
Afmetingen verpakking (BxDxH): | 586 x 734 x 250 mm |
Interface: | Mini SAS 4x |
Type processor: | RISC |
Temperatuur bij opslag: | -20 - 60 °C |
Intern: | Nee |
Luchtvochtigheid bij opslag: | 10 - 90 procent |
Type behuizing: | Rack (1U) |
Capaciteit voedingsunit (PSU): | 300 W |
Redundante voeding: | Ja |
Maat: | 2.5 " |
Aantal geïnstalleerde processoren: | 1 |
Aantal storage drives geïnstalleerd: | 10 |
Afmetingen (B x D x H): | 482.6 x 482.6 x 44.4 mm |
Beheerplatform: | SNMP |
Soorten RAID: | 0,1,5,6,10 |
Overdrachtssnelheid: | 1.2 Gbit/s |
Bedrijfstemperatuur (T-T): | 0 - 35 °C |
Relatieve vochtigheid in bedrijf (V-V): | 20 - 80 procent |
Interne cache: | 512 MB |
Heb je hulp nodig?
Als je hulp nodig hebt met AIC XD1100-1102 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Disk array AIC
25 Oktober 2022
Handleiding Disk array
- Disk array HP
- Disk array Buffalo
- Disk array D-Link
- Disk array Dell
- Disk array Fantec
- Disk array Fujitsu
- Disk array Hitachi
- Disk array Icy Box
- Disk array LaCie
- Disk array Netgear
- Disk array QNAP
- Disk array Seagate
- Disk array Sharkoon
- Disk array Synology
- Disk array Western Digital
- Disk array Vantec
- Disk array IoSafe
- Disk array SilverStone
- Disk array Addonics
- Disk array Intel
- Disk array Supermicro
- Disk array G-Technology
- Disk array Tandberg Data
- Disk array Areca
- Disk array Icy Dock
- Disk array HGST
- Disk array Sonnet
- Disk array CRU
- Disk array Promise Technology
- Disk array OWC
- Disk array Raidsonic
- Disk array Rocstor
- Disk array Infortrend
- Disk array Glyph
- Disk array IDIS
- Disk array IStarUSA
- Disk array Enhance
Nieuwste handleidingen voor Disk array
18 November 2024
16 November 2024
25 Juli 2024
25 Juli 2024
25 April 2024
25 April 2024
25 April 2024
16 April 2024
16 April 2024
16 April 2024