VWM-01 / VWM-02 / VWA-01 & VWA-04
Installation Manual
Video Wall Mounting Kit
VWM-01 VWM-02
2 3 4 5
VWM-01 Enclosed Parts
M6x12
*1 pcs *4 pcs *4 pcs
M8x14
*2 pcs *2 pcs
1
2 3 4 5
VWM-02 Enclosed Parts
M6x12
*1 pcs *4 pcs *4 pcs
M8x14
*2 pcs *2 pcs
1
Optional Proles VWA-01 + Brackets VWA-04
VWA-01 L= 2.000 mm VWA-04
Single use In-line use
Videowall use
VWM-01:
Installation of single-use or in-li use ne
VWM-02:
Easy installation of Videowall. Push- ction for out fun
build-in videowall sy c cting ervice of , ea onne and s
t displays. he
(ev lowes line c ill VWM- ) en t an st be 01
OPTIONAL
VWA- : 01
To install displays raigh in li For easy st t one ne. and
fas in-line or videowall set .t up
VWA- ( tional) 01 op
VWM-01/02
VWM-02
VWM-01VWM-01VWM-01
Set-up Guide
VWM-01/02
VWM-02
Physical Dimensions (mm)
500
93+10
0
526
100
200
300
400
400
280
65 40
8.5
1050
Max.fine adjustment
6.5 mm
93+10
0
60
430
17.5
8.5
52.5
93-293
(stroke=200)
+10
0
532
500
40
52.5-252
100
200
300
400
Max.fine adjustment
6.5mm
10
8.5
50
8.5
400
46
74
VWM-01 VWM-02
Installation
Sli t wallbrackets (2) wit the slot nut in the slot of the aluminium profile (1).de he
Positio te t m a sleightly turn on t lts. na he nd he bo
VWM-01: Mo t the brackets (3) with screw (4 or 5) on the backside of the display.un
VWM-02: Screw only t screws (4 or 5) in the V holes of t display and k he ESA he eep
a clearance of 4 m m.
Screw now the brackets with Profile(s) t wall. Line-up t profile(s) by on he he
ad g justin the wallbrackets (2).
For videowall installation check dist ce (H + 1 mm) and distan ance (W- mm) 264
an he edd make sure t profiles are levell (horizontally as well as vertically).
To sav installation time we sug st to use our itional profile VWA- . e ge add 01
VWM-01: Hook t display with brackets to the aluminium profile a make sure he nd
that justing screw (c) does t touch the profile.ad no
VWM-02: Hook t mo les to the aluminimum profile a make sure t t adjustinghe du nd ha
screw (c) d s not touch the profile. Place lt (a) with associated washer in t oe bo he
sliding nut, but not do tighten. Place the two modules with a rizontal distance ho
according to the width of t V . he ESA
265 97.5
97.5
W
H
265 265
W - 264 mm
H + 1 mm
01
03
02
04
1
2
2
4 5
4 5
4 5
4 5
3
3
a
b
c
a
b
c
Installation
Place the screen(s) in the center of the aluminium profile. Adjust vertical positions by slightly turning screw (d) or balance horizontallity by adjusting
screw (e). if installation is perfect, fix the brackets at the profile by screw ( c).
For videowall installation keep a clearancy of 1mm between the screens.
1 mm !
400
2.1 - 4 mm
05
07
06
08
4x
e4x
c
4x
6
a
b
c
a
b
c
4 5
4 5
4 5
4 5
d
1 mm !
1 mm !
09
11
10
12
4x
4x
4 5
f
e
c
VWM-02: Hook the brackets (6) to the aluminimum profile. Place bolt (a) with associated washer in the sliding nut, fix bracket with bolt (c) into the washer
through (b) but do not tighten. Place the two brackets (6) with a horizontal distance according to the width of the VESA and push sleightly on the brackets
(6) so they push out. Hang the display in the open bracket (6) by glyding the screws (4) or (5) into the key holes.
VWM-02: After hanging screen(s) on pushed-out brackets (6) teight-up screws (4) or (5). Keep a distance of 1 mm between 2 screens.
Check horizontal positions and fine-tune it by turning screw (e).
Check virtical position in the push-open and push-closed position and be aware of the 1 mm free space when opening and closing the brackets.
Push the screen, mounted on a VWM-02, by pressing against the indicated positions until a slight click is heard. The screen is now locked in the closed
position. Turn screws (c) to teight-up the mounts.
Hang the remaining screens by repeating the steps 4 until 10. Consider a spacing between the screens of about 1mm.
Replace screen
Press on the screen until a slight click is heard. The screen is now unlocked and will come forward when loosening pressure. Sufficiently loosen the
screws (4) or (5) at the rear of the screen, so that the screen can be lifted out of the keyholes.
Remove the screen from the “Push to Open” modules and if needed replace it with a new screen. Tighten the bolts (from Step A) again. Push on the
screen until a slight click is heard. The screen is locked in the closed position. If a display on the lowest profile needs service, then only press on the
screen above untill a slight click is heard. Now release bolt (a) and lift slightly the lower display off the profile.
By using VMW-01 and VMW-02 in a combination, only the defect display needs to be uninstalled.


Product specificaties

Merk: Ag Neovo
Categorie: Niet gecategoriseerd
Model: VWA-04
Kleur van het product: Zwart, zilver
Gewicht: 80 g
Breedte: 40 mm
Diepte: 40 mm
Hoogte: 40 mm
Materiaal behuizing: Metaal
Montagewijze: Muur
Maximale gewichtscapaciteit: 80 kg
Paneelmontage-interface: - mm
Maximale schermgrootte: 65 "
Minimale schermgrootte: 42 "

Heb je hulp nodig?