AFX Vaportite VTL476000LAJD2 Handleiding

AFX Verlichting Vaportite VTL476000LAJD2

Lees hieronder de 📖 handleiding in het Nederlandse voor AFX Vaportite VTL476000LAJD2 (2 pagina's) in de categorie Verlichting. Deze handleiding was nuttig voor 5 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Model #: VTL243500LAJD2
VTL476000LAJD2
LED Outdoor Luminaires
Ceiling Mount - Vapor Tight
120 277 - VAC / 60Hz
Page 1 of 2 8061547 R0
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this xture. Failure to comply with these instructions could result in potentially
fatal electric shock and/or property damage.
It is recommended that a qualied electrician perform all wiring. This xture must be wired in accordance with all national and local electrical codes.
Do not handle any energized xture or attempt to energize any xture with wet hands or while standing on a wet or damp surface or in water.
This xture is designed for use in a 120-277VAC, 60Hz fused circuit. This xture is compatible with 0-10V dimming circuit.
To reduce the risk of electrical shock, and to assure proper operation, this xture must be adequately grounded. To accomplish proper grounding, there must be a separate
ground wire (green) contact between this xture and the ground connection of your main power supply panel.
This xture is intended to be used for general door lighting in dry, damp or wet locations. For wet locations, xture must be mounted at least 48 inches above ground out
level.
Disclaimer
Changes or modications not expressly approved by the party responsible for compliance could void NOTE: This equipment the user’s authority to operate the equipment.
has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-005 (B) / NMB-005 (B). These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modications to this xture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
Assembly Instructions
Step 1 Preparing for installation
A. at fuse or circuit Disconnect electrical power
breaker box before installing or servicing any part
of this xture.
B. Carefully remove the LED xture from the carton.
C. Release the diuser (2) from the xture (1) by
unlatching all mechanical latches. Diuser is
tethered to the latch on both ends.
D. lip Release LED plate assembly (6) from c
brackets. LED plate is tethered to housing (1).
E. Identify location of mounting brackets on xture
relative to power source. Holes are supplied for
power connection at end or through the top. Fitting
is supplied for cord connection If top is used for .
connection, remove knockout and install plastic
cap (6) onto the front end for water tight seal.
F. set of replacement plastic latches are provided if A
factory install metal latches (8 are not desirable. ed )
Pull on the latch to unsnap it from the groove. To
install snap new latch by aligning pin onto the
receiving groove in reverse order of removal.
Step Mounting fixture 2
A. Select location for mounting the xture. Two
brackets (3) are supplied with drywall anchors &
screws (4) & (5 Follow drilling dimension for ).
brackets spacing for 48” or 24” fixture.
B. To locate, hold xture assembly up to ceiling with
power supply hole located over entryway for power
supply wires. Mark the locations of the mounting holes for brackets (3 on the ceiling. )
C. Take thexture down and punch a small hole into the ceiling at each location using a nail or awl to see if there is a wood joist. Attach to surface using fasteners and
sealing washers (not provided) appropriate to ceiling materials.
D. If there is a joist, use a suitable wood screw (4) to mount the xture housing. Where there is no joist to screw into, use drywall anchors (4) & (5) or toggle bolts (not
provided) of suitable length to mount housing securely to the ceiling.
E. Mount the xture with appropriate fasteners while passing the supply wires into the opening of the housing.
Wiring All wiring must take place inside junction box (not included)
Caution: Note: Make sure power is o at fuse or circuit breaker box. Check power wires for damage or scrapes. Use wire suitable for at least °C (194°F). 90 Most dwellings
built before 1985 have supply wire rated to 60C. Consult a qualied electrician ensure correct branch circuit conductor before installing.
Step 3 Wiring fixture
A. Make all wire connections to appropriate wire. Secure with wire nut and power connectors (supplied).
B. Strip o 1/2" insulation to expose bare wires on supply power source black (L) and white (N).
C. Connect the green wire from the xture to the supply power source ground wire.
D. Connect the black wire from the xture to the black (L) wire from supply power source. Connect the white wire from the xture to the For none dimming xture.
white (N) wire from supply power source. Pink and purple wires are not to be used and must be individually capped to prevent shorting.
E. . Connect the pink wire from thexture to the dimmer source gray wire. Connect the purple wire from the xture to the dimmer source For (0-10V) dimming xture
purple wire. Connect the white wire from the xture to the neutral (N) wire from dimming source per dimmer wiring instructions. Connect the black wire from thexture
to the control line (L) wire from dimmer supply power source per dimmer wiring instructions.
Model #: VTL243500LAJD2
VTL476000LAJD2
LED Outdoor Luminaires
Ceiling Mount - Vapor Tight
120 277 - VAC / 60Hz
Page 2 of 2 8061547 R0
Limited Factory Warranty
AFX warrants this xture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 5 years from date of
purchase. This warranty covers all component parts and extends only to replacement of defective xture or components; it does not cover failure due to improper installation,
misuse, mishandling or damage incurred in transit.
F. Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed outside of wire connectors.
G. -install LED plate to the clip brackets in the housing (1). Re
Step 4 Color changing temperature adjustment, CCT (if desired)
A. Adjust CCT switch according to the desired color temperature as shown below. Note: Fixture is preset to 3000K from factory.
Step 5 Diuser installation
A. Install diuser (2) onto housing by securing latches, rotating/alternating around edge of housing and capturing diuser with rounded lip. Snap latches closed. Twelve
latches for 48” and six for 24” version.
Step 6 store power at fuse or circuit breaker box Re


Product specificaties

Merk: AFX
Categorie: Verlichting
Model: Vaportite VTL476000LAJD2

Heb je hulp nodig?

Als je hulp nodig hebt met AFX Vaportite VTL476000LAJD2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Verlichting AFX

Handleiding Verlichting

Nieuwste handleidingen voor Verlichting