Aerospace Logic FL206 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Aerospace Logic FL206 (3 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 58 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
Aerospace Logic Inc.
Tel. 416 628 0725 - -
www.aerospacelogic.com
This document set is appl le to the following part number configurationsicab :
Part Number
Description
FL201D
Fuel level instrument for digital
senders, one tank
Part Number
Description
FL202D
Fuel level instrument for digital
senders, two tanks
Part Number
Description
FL203D
Fuel level instrument for digital
senders, three tanks
Part Number
Description
FL204D
Fuel level instrument for digital
senders, four tanks
Part Number
Description
FL205D
Fuel level instrument for digital
senders, five tanks
Part Number
Description
FL206D
Fuel level instrument for digital
senders, six tanks
FL20XD Fuel Level Resistive - Digital
Document # S200-FL20X 001D-
Rev 1.1 02/28/2017
Page 2 2 of
Aerospace Logic Inc.
Tel. 416-628 0725-
www.aerospacelogic.com
The Fastest Way To Install And Start Using This Product
NOTE: This product is certified as a primary replacement, new or secondary instrument
only when installation is performed in accordance with the documented instructions and
procedures.
1. Review the Warranty Statement before performing any tasks. Do not remove the
instrument from the sealed package until you agree with the stated terms.
2. If this instrument is to be installed in a certified aircraft, verify that the aircraft
model is listed on the Eligibility List (Canadian registered aircraft) or the
Approved Model List (USA and all other countries).
If it is NOT listed, contact your local authority and obtain the necessary
requirements or approvals before proceeding further.
For all other vehicles, including experimental aircraft continue with Step 3.
3. Follow the Installation Instructions exactly as noted, referring to the Wiring
Diagram as and when required. Note: The installation process has been
optimized based on the sequence of components to be installed. Installing the
product in any other way will, in all likelihood, take longer and be more complex.
Ensure that one of the Intensity Control options has been installed in accordance
with document # S200- - . DDC INST
4. Perform the Instrument Setup using the required data as listed in the Instrument
Setup procedure.
5. Validate that all functions perform as outlined in the Operations Guide.
6. Complete all regulatory documentation, if required.
F XD L20 Product Specifications
Document # S200-FL202D 006-
Rev 1.1 02/28/2017
Page 1 1 of
Aerospace Logic Inc.
Tel. 416-628 0725-
www.aerospacelogic.com
Certification / Compliance
TSO C55a
Environmental 160F -DO
A1CAASXXXXXXZBXXBBBCSBA1C11XXAX
Software 178B -DO
DC Power Source Input voltage 6 to 36 VDC
Power consumption 100mA
Load dump tolerance +60V
Direct spike tolerance - +/ 60V
Cable spike tolerance - > +/ 1KV
Operating Temperature Constant operating -15ÂșC to +55ÂșC
Short term operating (1hr) - Âș ÂșC 40 C to +70
Storage - Âș ÂșC 55 C to +85
Signal Input 5.0V Pulse Width Modulated (10Hz 300Hz)-
Sender Type TSO C55a Qualified SendersDigital
Display Fuel Quantity US Gallons or Litres
Accuracy C - Fuel Quantity AS405 +/ 1 USG
- Frequency +/ 0.1Hz
Range 0 to 120 USG (defined by fuel sender/tank size)
Display Sunlight readable LCD
80/80/80/80 Degree viewing angle
Annunciator Output 100mA sink with reverse EMF protection
Interface Connector - DB 25
Software Functionality
Primary Fuel level in all tanks
Trend Graph Graphic display of level vs time
Dimensions 6” 2.45” X 2.45” X 0.9
Weight (excluding harness) 4.05 oz
Finish Black anodized 6061 aluminum


Product specificaties

Merk: Aerospace Logic
Categorie: Meetapparatuur
Model: FL206

Heb je hulp nodig?

Als je hulp nodig hebt met Aerospace Logic FL206 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Aerospace Logic

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur