Ade ZW60-45 Handleiding

Ade Weegschaal ZW60-45

Lees hieronder de 📖 handleiding in het Nederlandse voor Ade ZW60-45 (20 pagina's) in de categorie Weegschaal. Deze handleiding was nuttig voor 47 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/20
OPERATING MANUAL
Electronic table scales
Control scale - Model ZW60-45
ZW60-210531-Rev006-UM-en
2
ZW60-210531-Rev006-UM-en
Table of Contents
Table of Contents .................................................................................................................. 2
1. Applications ............................................................................................................... 3
2. Delivery contents ....................................................................................................... 3
3. Safety instructions ..................................................................................................... 3
4. Set up of the scales ................................................................................................... 4
5. Operating and display elements ................................................................................. 5
5.1 Operating Controls ................................................................................................... 5
5.2 Button terms and functions ...................................................................................... 5
5.3 Display symbols ....................................................................................................... 6
5.4 Battery status indicator ............................................................................................ 7
6. Operation ................................................................................................................... 7
6.1 Zeroing the scale ..................................................................................................... 7
6.2 Taring ...................................................................................................................... 7
6.3 Determining the weight ............................................................................................ 8
6.4 Weighing in percent ................................................................................................. 8
6.5 Piece counting ......................................................................................................... 8
6.5.1 Method 1: Unknown reference weight ............................................................ 8
6.5.2 Method 2: Known reference weight ................................................................ 8
6.6 Presetting the maximum and minimum values for audible alarm .............................. 9
6.7 Totaliser ................................................................................................................... 9
6.7.1 Manual totaliser .............................................................................................10
6.7.2 Automatic totaliser .........................................................................................10
7. Parameters ...............................................................................................................11
8. Care and maintenance ..............................................................................................13
8.1 Cleaning .................................................................................................................13
8.2 Error indication .......................................................................................................13
8.3 Storage and Transport ............................................................................................13
8.4 Disposal ..................................................................................................................14
8.5 Warranty .................................................................................................................14
9. Technichal Data ........................................................................................................15
10. Declaration of Conformity .........................................................................................16
ZW60-210531-Rev006-UM-en 3
This symbol means: "Consult operating instructions". To achieve accurate re-
sults, read the instructions for use carefully before use and follow all instruc-
tions provided therein. Keep the instructions for use for future reference.
1. Applications
The ZW60 series digital checkweighing scale provides accurate, fast and versatile checkwei-
ghing and simple counting options and is designed for checkweighing in applications not re-
gulated by law.
- The ZW60-45 scale has a rated capacity of 45 kg with a digit interval of 1 g.
- All scales are equipped with stainless steel weighing platforms and ABS plastic housings.
- All scales have sealed keypads with colour-coded membrane switches.
- The display is a highly readable liquid crystal display (LCD) with extra large digits (digit
height is 52 mm). The LCD display is equipped with a backlight that can optionally be enab-
led or disabled.
- All scales have an auto zero function, an audible alarm for preset weights, an automatic
taring, a preset taring and a totaliser that allows to save and recall the number of pieces as
a total sum.
- The scale can be switched between such units as kg, g, lbs and oz.
- Power is supplied via a 230 V mains connection or a 6 V 4 Ah rechargeable battery.
2. Delivery contents
Included in the delivery are:
- Scales
- Rechargeable battery (integrated into the scale)
- Weighing platform
- Power adapter
- User manual incl. declaration of conformity
3. Safety instructions
It is essential that you read, understand and follow all instructions in these instructions for use
as well as the country-specific installation standards, the applicable safety regulations and
accident prevention regulations.
- Handle the scale with care and always keep in mind that it is a precision measuring instru-
ment.
- Protect the weighing platform from impacts and vibrations and do not overload the scale.
- The scale may only be operated and maintained by trained and authorised skilled person-
nel. Handling errors can lead to injuries or damage the scale.
- Before first use, make sure that the mains voltage and current type stated on the name
plate match the mains voltage and current type at the place of use.
- Lay the cables so that they cannot lead to a trip hazard.
- Lay the cables so that they cannot pose a risk of strangulation.
- Operate the device only within the permissible ambient conditions.
- Do not expose the scale to high temperatures, whether from neighbouring devices or direct
sunlight.


Product specificaties

Merk: Ade
Categorie: Weegschaal
Model: ZW60-45

Heb je hulp nodig?

Als je hulp nodig hebt met Ade ZW60-45 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Weegschaal Ade

Ade

Ade Amina Handleiding

9 December 2024
Ade

Ade MP901600 Handleiding

9 December 2024
Ade

Ade M111600 Handleiding

9 December 2024
Ade

Ade M108800 Handleiding

9 December 2024
Ade

Ade M319660 Handleiding

9 December 2024
Ade

Ade Nina BM 707 Handleiding

14 November 2024
Ade

Ade HWZ-221128 Handleiding

5 Augustus 2024
Ade

Ade MWSK-240717 Handleiding

5 Augustus 2024

Handleiding Weegschaal

Nieuwste handleidingen voor Weegschaal