Operating Manual
Class III Approved Scales
Electronic Bed Scale
M600020
M600020-210322-Rev008-UM-e
2 M600020-210322-Rev008-UM-e
Contents
Introduction .............................................................................................................................................. 3
Assembly and set up ............................................................................................................................... 3
Scope of delivery .................................................................................................................. 3
Power supply ........................................................................................................................ 3
Replacing rechargeable batteries ....................................................................................... 4
Tips for handling the batteries ............................................................................................ 4
Quality features ........................................................................................................................................ 4
Display ..................................................................................................................................................... 5
Description ............................................................................................................................ 5
Connecting additional devices ........................................................................................... 5
Housing and connections ................................................................................................... 6
Safety ....................................................................................................................................................... 6
Settings .................................................................................................................................................... 6
Setting date and time ........................................................................................................... 7
Operation ................................................................................................................................................. 7
Modes of operation .............................................................................................................. 7
Before weighing ................................................................................................................... 7
Weighing ............................................................................................................................... 8
Tare function ......................................................................................................................... 8
Hold function ........................................................................................................................ 8
Determining the Body Mass Index (BMI) ........................................................................... 9
Print out a record ................................................................................................................. 9
Care, servicing and recalibration ............................................................................................................. 9
Cleaning ................................................................................................................................ 9
Error messages .................................................................................................................... 9
Waste disposal ................................................................................................................... 10
Storage and transport conditions .................................................................................... 10
Warranty .............................................................................................................................. 10
Recalibration ....................................................................................................................... 10
Technical specifications ......................................................................................................................... 11
Conformity declaration ........................................................................................................................... 12
M600020-210322-Rev008-UM-e 3
Introduction
This symbol means: "Consult operating instructions". To achieve accurate results, read the
instructions for use carefully before use and follow all instructions provided therein. Keep the
instructions for use for future reference.
Your ADE electronic bed-scale is a quality, sturdy and durable product manufactured under the high standards
and regulations for calibrated class III scales in accordance with national regulations in Germany. The scale is
designed and manufactured primarily for the daily practice in hospitals and dialysis centres.
ADE instruction manuals have been prepared to provide the user with all the necessary knowledge about the
safe use of ADE scales and their related accessory equipment.
For further questions about how to use the products or about this or other service manuals, feel free to contact
your local ADE representative or visit our web page at www.ade-hamburg.de
In order to achieve the best possible results kindly read and follow the operation manual in all respects.
Assembly and set up
The ADE bed scale is supplied in a fully assembled condition. Please insure that your scale is being placed
vibration-free at a dry place. Dismantle packaging and foil carefully and remove the transport securing devic-
es. Place the weighing feet on a plain, dry and level surface before the weighing procedure.
Scope of delivery
4 Weighing shoes/ measuring feet with integrated ramp (numbered 1-4)
4 Locking aids
1 Mains adapter
Equipment trolley with integrated terminal box for connection to weighing shoes (numbered 1-4) and al-
ready mounted indicator
Operating Manual including “Certificate of Conformity”
Power supply
Power is supplied either by the rechargeable battery in the display unit or by the mains power via the supplied
power unit. The imprinted voltage value at the mains adapter must match the mains voltage at the place of
use. Connect the mains cable to the indicator and to a socket.
The wall socket must be located near to the unit and be easily accessible. Please use only the mains adapter
supplied by ADE. The mains adapter is charging the battery pack during normal operation.
When the battery is being charged for the first time a sufficient charging period of approx. 24 hours is neces-
sary to achieve a full battery load.
If the unit is in battery mode and the display indicates – , the battery needed to be recharged with the mains Lo
adapter. For a full battery load a charging period of 12-16 hours is required with the scale being switched off.
If– still appears at the display inform your service partner. Lo


Product specificaties

Merk: Ade
Categorie: Weegschaal
Model: M600020

Heb je hulp nodig?

Als je hulp nodig hebt met Ade M600020 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Weegschaal Ade

Ade

Ade Amina Handleiding

9 December 2024
Ade

Ade MP901600 Handleiding

9 December 2024
Ade

Ade M111600 Handleiding

9 December 2024
Ade

Ade M108800 Handleiding

9 December 2024
Ade

Ade M319660 Handleiding

9 December 2024
Ade

Ade Nina BM 707 Handleiding

14 November 2024
Ade

Ade HWZ-221128 Handleiding

5 Augustus 2024
Ade

Ade MWSK-240717 Handleiding

5 Augustus 2024

Handleiding Weegschaal

Nieuwste handleidingen voor Weegschaal