970-030
NO-PROOF-OF-PURCHASE LIMITED WARRANTY
See label on back of unit for details, or check
http://support.ACCUSPLIT.com
REGISTER NOW Please return
your AE520S Registration to the
Repair Center address in the
warranty, and we will let you
know about future products.
Email (preferred)
User
LCD Timer/Stopwatch/Clock
AE520S
Operating Instructions
SETUP
The unit operates on one ‘C’ size R14 battery that has a life expectancy in excess of one year.
Remove the battery cover and fit the R14 battery into the correct position. Replace the battery cover.
INTRODUCTION
ACCUSPLIT products use a common setting procedure called S1-2-3-4.
S1 = enter the setting mode
S2 = change the field to be set
S3 = change the field value(s)
S4 = exit the setting mode
TO SET CLOCK AND DATE
S1 - Slide the switch to the CLOCK SET (labeled as “SET”) position.
S3 - To set the time, press and hold the hour and minute buttons separately to fast forward to the correct
time. Press the second button to zero the second display.
S3 - To change between 12 and 24 displays, press the SPLIT/RESET button.
S2 - To set the date display, press the START/STOP button to alter the display.
S3 - To adjust the day, date and month, press the HOUR, MINUTE & SECOND BUTTONS respectively.
TO SET ALARM
S2 - Slide the switch to the ALARM (ringing alarm clock icon) position.
S3 - Set the alarm by pressing the HOUR & MINUTE buttons.
Turn the alarm function on by pressing the CLEAR button. The alarm sign will show on the left of the display.
To turn the alarm sound off, press either of the top buttons.
To turn the alarm function off, with the slide switch at ALARM, press the CLEAR button.
TO OPERATE STOPWATCH
Slide the switch to the Stopwatch icon (COUNT UP) position.
There are four modes of count up that are selectable, which can be changed by pressing the HOUR button.
STW 1 second to 23 hours, 59 minutes, 59 seconds.
STW + 1/100s 1/100 second to 59 minutes, 59.99 seconds
STW + DS 1/100 second to 9999.99 seconds
STW + DM 1/100 minute to 1999.99 minutes
The count up function operates using the START/STOP buttons with a lap option by pressing the
SPLIT/RESET button. When the lap is being held the display shows SPL above the seconds display. To
restart the count up after the lap time has been noted, press the SPLIT/RESET button. To stop and set
the time back to zero, press the START/STOP button and then the RESET button.
TO OPERATE MEMORY TIMER
S2 - Slide the switch to the hourglass icon (TIMER) position.
S3 - Press the HOUR MINUTE & SECOND buttons to set the time period required. If an error in setting
occurs, press the RESET button and start again. The memory facility will display MEM on the right of the
display, after setting the unit and before pressing the START button. When the set time has elapsed an
alarm will sound, which is turned off by pressing the STOP button. After the alarm has sounded, the
display will count up the time taken to turn off the alarm. After the STOP button has been pressed at the
end of the count down period, the last timing period that is stored in the memory is displayed.
The timing period can be stopped (”Time Out”) and re-started (”Time In”) by pressing the START/STOP button.
Product specificaties
Merk: | Accusplit |
Categorie: | Klok |
Model: | AE520S |
Heb je hulp nodig?
Als je hulp nodig hebt met Accusplit AE520S stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Klok Accusplit
13 Mei 2023
Handleiding Klok
- Klok Braun
- Klok IKEA
- Klok Casio
- Klok Fysic
- Klok Xiron
- Klok Ade
- Klok Alecto
- Klok Amplicom
- Klok Ascot
- Klok Audiovox
- Klok Auriol
- Klok Balance
- Klok Balance Time
- Klok BBrain
- Klok Dexford
- Klok Digi-tech
- Klok Ecom
- Klok Elro
- Klok Eurochron
- Klok Fisher Price
- Klok Geemarc
- Klok Gingko
- Klok Gira
- Klok Global Tronics
- Klok GlobalTronics
- Klok Glunz
- Klok Hager
- Klok Hama
- Klok Hermle
- Klok IHome
- Klok Irox
- Klok Karlsson
- Klok Kogan
- Klok Konig
- Klok Krontaler
- Klok La Crosse
- Klok Lenovo
- Klok Lexon
- Klok Livoo
- Klok Lorus
- Klok Lydion
- Klok Marquant
- Klok Mebus
- Klok Mondaine
- Klok Muse
- Klok Nedis
- Klok Perel
- Klok Profile
- Klok Ranex
- Klok RCA
- Klok Salter
- Klok Sempre
- Klok Taylor
- Klok Techno Line
- Klok Technoline
- Klok TFA
- Klok Tronic
- Klok United Office
- Klok Velleman
- Klok Ventus
- Klok Vitek
- Klok Weinberger
- Klok Jacob Jensen
- Klok Jung
- Klok Oregon Scientific
- Klok McIntosh
- Klok Camry
- Klok ECG
- Klok EMOS
- Klok Cresta
- Klok Citizen
- Klok Trevi
- Klok Zuiver
- Klok Chacon
- Klok Valcom
- Klok Dormakaba
- Klok AcuRite
- Klok ART
- Klok La Crosse Technology
- Klok AV:link
- Klok Elation
- Klok ASA
- Klok TFA Dostmann
- Klok Antelope Audio
- Klok Equity
- Klok DB Technologies
- Klok Focus Electrics
- Klok Pyramid
- Klok CyberData Systems
- Klok Electronics International
- Klok Antelope
- Klok Bearware
Nieuwste handleidingen voor Klok
14 December 2024
14 December 2024
14 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024