Quick Guide Start
UHF 6 Pro Series Reader
Version: 1 .0
Date: August 2018
1
1. Product Summary
UHF 6Pro series is a new generation of RFID UHF series product of our
company's independent research and development of the long distance card
reader system for parking lots.
The product adapts Impinj R2000 card reader chip, and the card reader part
adapts module integrated design. It has stable card reading performance, good
card reading performance consistency, long service span, minimized external
interference, and the product adapts waterproof casing design.
The product also fully meets the CE, FCC technology requirements of the
product, and has obtained CE, FCC and other security certifications.
2. Overview
Front View
Lateral View and Interface
NOTE:
Antenna
Working Frequency:
UHF 6E Pro: 865MHz ~ 868MHz
UHF 6F Pro: 902MHz ~ 928MHz
Read Range:
Handheld stable 18 meters
Mounting
Bracket
Cable Definition
NO Color Function
1 Red +12V
2 Black GND
3 Purple Trigger Point
(Active- low)
4 0 Green Wiegand D
5 White Wiegand D1
6 USB Connector
Cables
USB
2
1) In "Trigger Read" work mode, the reader will not read cards before a low level
signal to "Trigger Point" is delivered. "Trigger Point" is mainly used for
working with the ground sensor of vehicle parking system.
2) isIn "Always Read" work mode, once the card in the effective range, the
reader will output the card number via Wiegand continually.
3. Technical Parameter
Working Voltage DC9V ~ 12V
Working Current 1.2A +/- 10%
Working Temperature - ~ 20 ℃+60 ℃
Working Humidity <95%(+25°C)
Interface Protocol EPC global UHF Class 1Gen2/ ISO 18000-
6C,ISO
18000- 6B
Working Frequency 865MHz~868MHz;902MHz~928MHz
Output Power 10dBm ~ 33dBm
Communication Interface
Wiegand 26/34; USB
Reading Distance Stable 18 meters
Atenna Gain 9dBI
Dimension 310mm*310mm*90mm( ) ±5mm
Length of cable 1400±50mm
4 . Safety Precautions
1) The reader working voltage ranges from DC9V to DC16V, it is recommended
to use DC12V /3A power supply.
2) Please wire according to the cable definition.
5 . Modifying Setting via Demo


Product specificaties

Merk: ZKTeco
Categorie: Toegangscontrolesysteem
Model: UHF 6Pro

Heb je hulp nodig?

Als je hulp nodig hebt met ZKTeco UHF 6Pro stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Toegangscontrolesysteem ZKTeco

Handleiding Toegangscontrolesysteem

Nieuwste handleidingen voor Toegangscontrolesysteem