Operation Manual
Waste Water Pump
62820 62821,
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.
https://www.XPOtool.com Item 62820, 62821 Page 2
The Tool Experts
05 2022-1
The information contained in this document may alter at any time without previous notice. It is prohibited
to copy or spread any parts of this document in any way without prior written allowance. All rights re-
served.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing
from you.
Send an e-mail to:
service@wiltec.info
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany
To return orders for exchange, repair, or other purposes, please use the following address. Attention!
To allow for a smooth execution of your complaint or return, it is important to contact our customer
service team before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
https://www.XPOtool.com Item 62820, 62821 Page 3
The Tool Experts
05 2022-1
Introduction
Thank you for purchasing this quality product. To minimise the risk of injury we urge that our clients
take some basic safety precautions when using this device. Please read the operation instruc-
tions carefully and make sure you have understood its content.
Keep these operation instructions safe.
Safety instructions
Operation of the pump
• Familiarise yourself with the use of the pump, its limitations, and possible dangers.
• Make sure that the power source meets the requirements of your device.
• Disconnect the pump from the mains before carrying out maintenance work.
• Release the pressure in the system before performing maintenance on a component.
• Drain the liquid from the system before carrying out maintenance on the pump.
• Secure the discharge line before starting the pump. An unsecured discharge line may recoil and
cause injury and/or damage to property.
• Before each use, check the hose for wear and damage. Make sure that all connections are
properly secured.
• Occasionally check the pump and system components. Keep the pump and the system free of
residues and contaminants. Carry out maintenance when necessary.
• Provide means to relieve pressure on pumps whose discharge line may be shut off or clogged.
Personal safety
• Always wear safety goggles when working with or on a pump.
• Keep your work area clean, tidy, and well lit. Stow away tools and accessories when no longer
using them.
• Keep bystanders away from your work area.
• Child-proof your workplace by using padlocks and master switches and removing ignition keys.
• When connecting an electrically driven pump, all electrical and safety regulations must be fol-
lowed.
• The pump motor is equipped with an automatic resetting thermal protection and can restart
unexpectedly.
• This device is designed for 230 V operation only. To reduce the risk of electric shock, make sure
the device is connected to a properly installed safety plug. Danger of electric shock!
• All wiring should be done by a qualified electrician.
• Keep the mains cable away from sharp objects, hot surfaces, oil, and chemicals. Avoid bending
the cable. Immediately replace or repair damaged or worn cables.
• Use cables of sufficient size to minimise voltage drop on the motor.
• Do not touch a running engine. Modern motors can develop high temperatures during operation.
Additional precautions
• Have the following things checked by an expert before using the pump: earth connection, neutral
line.
• Residual current circuit breakers must comply with the relevant safety regulations and work
without faults.
• Electrical connections must be protected from humidity.
• If there is a risk of flooding, the electrical connections must be directed to higher spot.a
• The circulation of aggressive liquids and abrasives must be avoided absolutely.
• The waste water pump must be protected from frost and from running dry.
• The pump must be supplied via a residual current circuit breaker (RCD) with a rated fault oper-
ating current of no more than .30 mA


Product specificaties

Merk: WilTec
Categorie: Waterpomp
Model: 62821

Heb je hulp nodig?

Als je hulp nodig hebt met WilTec 62821 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Waterpomp WilTec

WilTec

WilTec 63910 Handleiding

7 December 2023
WilTec

WilTec 50967 Handleiding

17 November 2023
WilTec

WilTec 50453 Handleiding

17 November 2023
WilTec

WilTec 52007 Handleiding

17 November 2023
WilTec

WilTec 50965 Handleiding

17 November 2023
WilTec

WilTec 50266 Handleiding

17 November 2023
WilTec

WilTec 50268 Handleiding

17 November 2023
WilTec

WilTec 51541 Handleiding

17 November 2023
WilTec

WilTec 50921 Handleiding

17 November 2023
WilTec

WilTec 51561 Handleiding

17 November 2023

Handleiding Waterpomp

Nieuwste handleidingen voor Waterpomp