Westinghouse WRJ911US Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Westinghouse WRJ911US (4 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 39 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Universal Cooker Hood Installation and Operation Manual
The instructions in this manual are for cooker hood models:
WRJ600U, WRJ603U, WRJ611U, WRJ900U,WRJ911U,RHN6, RHN9.
These cooker hoods are domestic appliances which have been manufactured and tested to comply with Australian and New Zealand
Standard AS/NZS 3350.2.31.
Safety Warnings
?Young children should be supervised to ensure they do not play with the cooker hood.
?The cooker hood is not intended for use by young children or infirm persons without supervision.
?Ensure the cooker hood is switched off before carrying out maintenance, to avoid any possibility of electric shock.
?Grease filters must be removed every four weeks (maximum) for cleaning to reduce the risk of fire.
?Do not under the cooker hood.flamb e¢
?This cooker hood is not recommended for .barbeques
?The exhaust air from the cooker hood must not be discharged into any heating flue, which may carry combustion products
from other sources.
?Exhaust air must not be discharged into a wall cavity, unless the cavity is designed for the purpose.
?There must be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning gas
or other fuels.
?Always cover lit gas burners with pots or pans when the cooker hood is in use.
?Always switch off gas burners before you remove pots or pans.
Cleaning
Wipe the cooker hood body and flue with a sponge or soft cloth soaked in warm soapy water. Do not use oven cleaners or
other abrasive materials.
Electrical Connection
?Check that the mains voltage matches with the voltage on the data plate inside the cooker hood.
?Check that the installation complies with standards of local gas and electricity authorities.
?If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in
order to avoid a hazard.
Accessories
?Use 125mm round exhaust ducting for best performance.
?When using flexible duct always install duct with the wire helix pulled taut to minimise pressure loss.
?Try to keep exhaust duct short and straight.
?Keep bends in the exhaust duct to a minimum.
?Do not reduce the size or restrict exhaust duct.
Ducting Accessories AR125RC
AR125F
AR125FD
AR125WV
Roof cowl
Flue
1200mm length
Alternative flue connection
1 metre flexible duct with joiners
Wall vent
(includes 400mm of flue)
Flue collar
1 supplied
with hood
Flue joiner
-plain AR125FJ
-damper
AR125FJD
Flashing
Not Supplied
90 bend
AR125B
Flue
600650
GAS
ELECTRIC
Stainless Steel Models
Before installing the cooker hood, remove all protective plastic covering from stainless steel surfaces.
Use at least 4 screws (not provided) and the mounting holes provided to securely mount the cooker hood.
Make sure that the cooker hood is level and free from twist.
Ducted installation
Select required exhaust outlet, remove hole
plug and snap fit flue exhaust collar.
RECIRCULATE
EXHAUST
Setting of circulation air doors - single fan models
Setting of circulation air doors - dual fan models
RECIRCULATE
EXHAUST
c
L
c
L
60
100
79
25
25
30
25
Air Recirculating Outlet
Rear Fixing Points (4)
143
Recommended
Top Fixing Points
Recommended
90cm wide models
60cm wide models
nominal width 598
nominal width 898
(use 2 from each end)
160
500
Top and Rear Exhaust Outlets
35
300
30
105
Cooker Hood Operation
Best results are obtained by using a low speed for normal conditions and a high speed when odours are more concentrated. Turn the
hood on a few minutes before you start cooking. It should by left on after cooking for about 15 minutes or until all odours have
disappeared.
Slide switch controls
Light switch:
Extractor fan switch:
Slide position I:
Slide position II:
Slide position III:
This switch is used to turn the light
fitted in the hood on and off.
Used to select fan speeds
Fan speed Lo.
Fan speed Med.
Fan speed High.
Press button switch controls
Light switch: ON Depress light button to turn light . Press light
button to turn light .OFF
Extractor fan switch interlocked switching: Select a fan
speed, depress button to turn fan . Press button to turn On (O)
fan .OFF
Replacing lamps:
Ensure the appliance is switched off before carrying out
maintenance, to avoid any possibility of electric shock.
Remove grease filter to replace lamp. Replace with 40W
(maximum) E14 candle lamp.
Recirculating accessory:
Optional carbon filter ARCFD for recirculating mode only.
Maintenance:
Clean grease filters every three to four weeks maximum. Greasy
filters are a fire risk.
Remove the grease filters, soak and agitate in hot soapy water.
Rinse, drain and shake well before replacing filters.
Do not use oven cleaners or other caustic materials.


Product specificaties

Merk: Westinghouse
Categorie: Afzuigkap
Model: WRJ911US

Heb je hulp nodig?

Als je hulp nodig hebt met Westinghouse WRJ911US stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Westinghouse

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap

Miele

Miele DA 6520 D Handleiding

21 November 2024
Miele

Miele DA 420-4 Handleiding

21 November 2024
Miele

Miele DA 2660 Handleiding

21 November 2024
XO

XO R230W Handleiding

21 November 2024
Ilve

Ilve AGK90 Handleiding

20 November 2024
Ilve

Ilve AGQ90 Handleiding

20 November 2024
Ilve

Ilve AGQ60 Handleiding

20 November 2024
Ilve

Ilve AGQ120 Handleiding

20 November 2024
Ilve

Ilve AGK120 Handleiding

20 November 2024