Westinghouse WGen9500DFc Handleiding

Westinghouse Generator WGen9500DFc

Lees hieronder de 📖 handleiding in het Nederlandse voor Westinghouse WGen9500DFc (104 pagina's) in de categorie Generator. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/104
USER MANUAL
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer
service at 855-944-3571.
W 9500Gen DFc
Dual Fuel Portable Generator
Gasoline: 9500 Running Watts | 12500 Peak Watts
Propane: 8500 Running Watts | 11200 Peak Watts
2 | Westinghouse Outdoor Power Equipment, LLC
INTRODUCTION
INTRODUCTION
INTRODUCTION
WARNING: Operating, servicing, and maintaining
this equipment can expose you to chemicals including
engine exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects or other reproductive harm. To
minimize exposure, avoid breathing exhaust, and wear
gloves or wash your hands frequently when servicing
this equipment. For more information go to www.
P65warnings.ca.gov.
DISCLAIMERS
All information, illustrations, and speciî·”cations in
this manual were in effect at the time of publishing.
The illustrations used in this manual are intended as
representative reference views only. We reserve the right
to make any speciî·”cation or design change without notice.
ALL RIGHTS RESERVED
All rights reserved. No reproduction allowed in any form
without written permission from Westinghouse Outdoor
Power Equipment, LLC.
Read this manual before using or performing
maintenance on this product. Failure to follow
the instructions and safety precautions in this
manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
INTRODUCTION
INTRODUCTION
WARNING: Operating, servicing, and maintaining
this equipment can expose you to chemicals including
engine exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects or other reproductive harm. To
minimize exposure, avoid breathing exhaust, and wear
gloves or wash your hands frequently when servicing
this equipment. For more information go to www.
P65warnings.ca.gov.
DISCLAIMERS
All information, illustrations, and speciî·”cations in
this manual were in effect at the time of publishing.
The illustrations used in this manual are intended as
representative reference views only. We reserve the right
to make any speciî·”cation or design change without notice.
ALL RIGHTS RESERVED
All rights reserved. No reproduction allowed in any form
without written permission from Westinghouse Outdoor
Power Equipment, LLC.
DANGER
Read this manual before using or performing
maintenance on this product. Failure to follow
the instructions and safety precautions in this
manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
INTRODUCTION
INTRODUCTION 2 ......................................................................
DISCLAIMERS 2 .........................................................................
ALL RIGHTS RESERVED 2 ........................................................
INTRODUCTION
INTRODUCTION 2 ......................................................................
DISCLAIMERS 2 .........................................................................
ALL RIGHTS RESERVED 2 ........................................................
SPECIFICATIONS....................................................................3
PRODUCT REGISTRATION 3 ....................................................
SPECIFICATIONS....................................................................3
PRODUCT REGISTRATION 3 ....................................................
SAFETY
SAFETY DEFINITIONS............................................................4
SAFETY SYMBOLS 4 .................................................................
SAFETY
SAFETY DEFINITIONS............................................................4
SAFETY SYMBOLS 4 .................................................................
SAFETY INSTRUCTIONS 5 .......................................................
GFCI 8 .........................................................................................
CO SENSOR 9 ............................................................................
ACTION LABEL ........................................................................9
CONTROL PANEL CO AUTO-SHUTOFF 9 ................................
SAFETY LABELS AND DECALS 10 ...........................................
COMPONENTS
GENERATOR COMPONENTS ..............................................11
CONTROL PANEL COMPONENTS 12 .......................................
ASSEMBLY
CARTON CONTENTS 13 ...........................................................
INSTALL FEET AND WHEELS 13 ..............................................
INITIAL OIL FILL 14 ....................................................................
FUEL ......................................................................................14
CONNECT A LPG/PROPANE TANK ......................................15
CONNECT THE BATTERY ....................................................16
OPERATION
GENERATOR LOCATION 17 ......................................................
GROUNDING 17 .........................................................................
HIGH ALTITUDE OPERATION ..............................................18
REMOTE START ...................................................................18
FUEL SELECTOR SWITCH 19 ..................................................
BREAK-IN PERIOD 19 ...............................................................
BEFORE STARTING THE GENERATOR 19 ..............................
STARTING THE ENGINE: GASOLINE 19 ..................................
STARTING THE ENGINE: PROPANE 20 ...................................
SWITCHING FUEL SOURCES 20 ..............................................
STOPPING THE ENGINE ......................................................20
FREQUENCY OF USE 20 ..........................................................
AC CIRCUIT BREAKERS 21 ......................................................
POWER MANAGEMENT 22 .......................................................
EXTENSION CORDS 22 ............................................................
ST SWITCH 23 ............................................................................
TRANSPORTING 23 ...................................................................
MAINTENANCE
MAINTENANCE SCHEDULE 24 ................................................
MAINTENANCE REPLACEMENT PARTS 24 ............................
AIR FILTER MAINTENANCE 24 .................................................
ENGINE OIL CHANGE 25 ..........................................................
SPARK PLUG MAINTENANCE 26 .............................................
SPARK ARRESTOR SERVICE ..............................................26
FUEL FILTER 27 .........................................................................
BATTERY MAINTENANCE 27 ....................................................
BATTERY REPLACEMENT 27 ...................................................
STORAGE 28 ..............................................................................
VALVE CLEARANCE 29 .............................................................
TROUBLESHOOTING
TROUBLESHOOTING 30 ...........................................................
EXPLODED VIEWS AND PARTS LISTS
EXPLODED VIEWS 32 ...............................................................
ESPAÑOL ...............................................................................39
FRANÇAIS 71 .............................................................................
Westinghouse Outdoor Power Equipment, LLC | 3
SPECIFICATIONS
Running Watts: 9500 Gasoline
8500 LPG
Peak Watts: 12500 Gasoline
11200 LPG
Rated Voltage: 120V/240V
Rated Power @1.0 Power
Factor:
9.5 kVA Gasoline
8.5 kVA LPG
Peak Power: 12.5 kW Gasoline
11.2 kW LPG
Rated frequency: 60 Hz @ 3600 RPM
Phase: Single phase
Total Harmonic
Distortion: ≤ 23%
Engine Displacement: 457 cc
Starting Type: Recoil, Electric Start,
Remote
Fuel Capacity: 6.6 Gallons (25 Liters)
Fuel Type: Unleaded gasoline
87–93 octane*
Oil Capacity: 1.16 US Quart (1.1 Liter)
Oil Type: SAE 10W-30
Spark Plug: 97108 (F7TC)
Spark Plug Gap: 0.024 – 0.032 in.
(0.60 – 0.80 mm)
Valve Intake
Clearance:
0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
Valve Exhaust
Clearance:
0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
AC Grounding System: Neutral bonded to frame
Voltage Regulator: AVR
Alternator Type: Brushed
Maximum Ambient
Temperature: 104°F (40°C)
Certications: • EPA
• CARB
*Ethanol content of 10% or less. DO NOT use E15 or E85.
UPDATES
The latest User Manual for your Westinghouse
generator can be found under our support tab. https://
westinghouseoutdoorpower.com/pages/manuals
Or scan the following QR code with your smartphone
camera to be directed to the link.
This product is designed and rated for continuous
operation at ambient temperatures up to 104°F (40°C).
If needed, this product can be operated at temperatures
ranging from 5°F (15°C)–122°F (50°C) for short periods.
If the product is exposed to temperatures outside of this
range during storage, it should be brought back within
this range before operation. This product must ALWAYS
be operated outdoors in a well-ventilated area and far
away from doors, windows, and other vents.
Maximum wattage and current are subject to and
limited by such factors as fuel BTU content, ambient
temperature, altitude, engine conditions, etc. Maximum
power decreases about 3.5% for each 1,000 feet above
sea level, and will also decrease about 1% for each 10°F
(6°C) above 60°F (16°C) ambient temperature.
PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to
register your Westinghouse generator.
You can register by:
• Completing and mailing the product registration card
included in the carton.
• Registering your product online at:
https://westinghouseoutdoorpower.com/pages/
warranty-registration
• Scan the following QR code with your smartphone
camera to be directed to the mobile registration link.
• Sending the following product information to:
Westinghouse Outdoor Power
Warranty registration
777 Manor Park Drive
Columbus, OH 43228
For Your Records
Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:
IMPORTANT: Keep your purchase receipt for trouble-free
warranty coverage.
SPECIFICATIONS
Speciî·”cations
Running Watts: 9500 Gasoline
8500 LPG
Peak Watts: 12500 Gasoline
11200 LPG
Rated Voltage: 120V/240V
Rated Power @1.0 Power
Factor:
9.5 kVA Gasoline
8.5 kVA LPG
Peak Power: 12.5 kW Gasoline
11.2 kW LPG
Rated frequency: 60 Hz @ 3600 RPM
Phase: Single phase
Total Harmonic
Distortion: ≤ 23%
Engine Displacement: 457 cc
Starting Type: Recoil, Electric Start,
Remote
Fuel Capacity: 6.6 Gallons (25 Liters)
Fuel Type: Unleaded gasoline
87–93 octane*
Oil Capacity: 1.16 US Quart (1.1 Liter)
Oil Type: SAE 10W-30
Spark Plug: 97108 (F7TC)
Spark Plug Gap: 0.024 – 0.032 in.
(0.60 – 0.80 mm)
Valve Intake
Clearance:
0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
Valve Exhaust
Clearance:
0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
AC Grounding System: Neutral bonded to frame
Voltage Regulator: AVR
Alternator Type: Brushed
Maximum Ambient
Temperature: 104°F (40°C)
Certications: • EPA
• CARB
*Ethanol content of 10% or less. DO NOT use E15 or E85.
UPDATES
The latest User Manual for your Westinghouse
generator can be found under our support tab. https://
westinghouseoutdoorpower.com/pages/manuals
Or scan the following QR code with your smartphone
camera to be directed to the link.
NOTICE
This product is designed and rated for continuous
operation at ambient temperatures up to 104°F (40°C).
If needed, this product can be operated at temperatures
ranging from 5°F (15°C)–122°F (50°C) for short periods.
If the product is exposed to temperatures outside of this
range during storage, it should be brought back within
this range before operation. This product must ALWAYS
be operated outdoors in a well-ventilated area and far
away from doors, windows, and other vents.
Maximum wattage and current are subject to and
limited by such factors as fuel BTU content, ambient
temperature, altitude, engine conditions, etc. Maximum
power decreases about 3.5% for each 1,000 feet above
sea level, and will also decrease about 1% for each 10°F
(6°C) above 60°F (16°C) ambient temperature.
PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to
register your Westinghouse generator.
You can register by:
• Completing and mailing the product registration card
included in the carton.
• Registering your product online at:
https://westinghouseoutdoorpower.com/pages/
warranty-registration
• Scan the following QR code with your smartphone
camera to be directed to the mobile registration link.
• Sending the following product information to:
Westinghouse Outdoor Power
Warranty registration
777 Manor Park Drive
Columbus, OH 43228
For Your Records
Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:
IMPORTANT: Keep your purchase receipt for trouble-free
warranty coverage.
INTRODUCTION


Product specificaties

Merk: Westinghouse
Categorie: Generator
Model: WGen9500DFc

Heb je hulp nodig?

Als je hulp nodig hebt met Westinghouse WGen9500DFc stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Generator Westinghouse

Handleiding Generator

Nieuwste handleidingen voor Generator