INTRODUCTION
WARNING: Operating, servicing, and maintaining
this equipment can expose you to chemicals including
engine exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects or other reproductive harm. To
minimize exposure, avoid breathing exhaust, and wear
gloves or wash your hands frequently when servicing
this equipment. For more information go to www.
P65warnings.ca.gov.
DISCLAIMERS
All information, illustrations, and speciî·”cations in
this manual were in effect at the time of publishing.
The illustrations used in this manual are intended as
representative reference views only. We reserve the right
to make any speciî·”cation or design change without notice.
ALL RIGHTS RESERVED
All rights reserved. No reproduction allowed in any form
without written permission from Westinghouse Outdoor
Power Equipment, LLC.
DANGER
Read this manual before using or performing
maintenance on this product. Failure to follow
the instructions and safety precautions in this
manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
INTRODUCTION
DISCLAIMERS 2 .........................................................................
ALL RIGHTS RESERVED 2 ........................................................
SPECIFICATIONS....................................................................3
SAFETY
SAFETY DEFINITIONS............................................................4
SAFETY SYMBOLS 4 .................................................................
SAFETY INSTRUCTIONS 5 .......................................................
SAFETY LABELS AND DECALS 7 .............................................
FEATURES
CONTROL PANEL COMPONENTS 8 .........................................
GENERATOR COMPONENTS 9 ................................................
DIGITAL DATA CENTER (IGEN2500) 9 ......................................
ASSEMBLY
CARTON CONTENTS 10 ...........................................................
INITIAL OIL FILL 10 ....................................................................
FUEL ...................................................................................... 11
OPERATION
GENERATOR LOCATION 12 ......................................................
GROUNDING 12 .........................................................................
HIGH ALTITUDE OPERATION ..............................................12
BREAK-IN PERIOD 13 ...............................................................
FREQUENCY OF USE 13 ..........................................................
BEFORE STARTING THE GENERATOR 13 ..............................
STARTING THE ENGINE ......................................................13
STOPPING THE ENGINE ......................................................13
ECO MODE 14 ............................................................................
AC CIRCUIT BREAKER.........................................................14
OVERLOAD RESET 14 ..............................................................
POWER MANAGEMENT 15 .......................................................
EXTENSION CORDS 16 ............................................................
PARALLEL OPERATION........................................................17
TRANSPORTING 17 ...................................................................
MAINTENANCE
MAINTENANCE SCHEDULE 18 ................................................
ENGINE SERVICE COVER 18 ...................................................
AIR FILTER MAINTENANCE 18 .................................................
ENGINE OIL LEVEL CHECK 19 .................................................
ENGINE OIL CHANGE 20 ..........................................................
SPARK PLUG MAINTENANCE 20 .............................................
SPARK ARRESTOR SERVICE ..............................................21
STORAGE 21 ..............................................................................
VALVE CLEARANCE 22 .............................................................
TROUBLESHOOTING
TROUBLESHOOTING 23 ...........................................................
EXPLODED VIEW
IGEN2200 EXPLODED VIEW 24 ...............................................
IGEN2500 EXPLODED VIEW 28 ...............................................
SCHEMATICS
IGEN2200 SCHEMATICS 32 ......................................................
IGEN2500 SCHEMATICS 33 ......................................................
ESPAÑOL ..............................................................................34
FRANÇAIS .............................................................................57
Westinghouse Outdoor Power Equipment, LLC | 3
INTRODUCTION
SPECIFICATIONS
Speciî·”cations iGen2200 iGen2500
Running Watts: 1800 2200
Peak Watts: 2200 2500
Rated Voltage: 120V 120V
Rated frequency: 60 Hz 60 Hz
Phase: Single phase Single phase
Total Harmonic
Distortion: ≤ 3% ≤ 3%
Engine Displacement: 80 cc 98 cc
Starting Type: Recoil Recoil
Fuel Capacity: 1.14 Gallon (4.3 L) 0.98 Gallon (3.7 L)
Fuel Type: 87–93 octane 87–93 octane* *
Oil Capacity: 0.37 US qt (0.35 L) 0.37 US qt (0.35 L)
Oil Type: 10W30 10W30
Spark Plug: E6RTC E6RTC
Spark Plug Gap: 0.024 – 0.032 in.
(0.60 – 0.80 mm)
0.024 – 0.032 in.
(0.60 – 0.80 mm)
Valve Intake
Clearance:
0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
Valve Exhaust
Clearance:
0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
AC Grounding System: Floating neutral Floating neutral
Voltage Regulator: Digital Digital
Alternator Type: Permanent magnet Permanent magnet
Maximum Ambient
Temperature: 104°F (40°C) 104°F (40°C)
Certiî·”cations:
• EPA
• CARB
• CSA Group
• EPA
• CARB
*Ethanol content of 10% or less. DO NOT use E15 or E85.
PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to
register your Westinghouse generator.
You can register by:
• Completing and mailing the product registration card
included in the carton.
• Registering your product online at:
https://westinghouseoutdoorpower.com/pages/
warranty-registration
• Sending the following product information to:
Westinghouse Outdoor Power
Warranty registration
777 Manor Park Drive
Columbus, OH 43228
For Your Records
Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:
IMPORTANT: Keep your purchase receipt for trouble-free
warranty coverage.
NOTICE
This product is designed and
rated for continuous operation
at ambient temperatures up
to 104°F (40°C). If needed,
this product can be operated
at temperatures ranging from
5°F (15°C)–122°F (50°C) for
short periods. If the product
is exposed to temperatures
outside of this range during
storage, it should be brought
back within this range before
operation. This product must
always be operated outdoors
in a well-ventilated area and
away from doors, windows,
and other vents.
Maximum wattage and current
are subject to and limited
by such factors as fuel BTU
content, ambient temperature,
altitude, engine conditions, etc.
Maximum power decreases
about 3.5% for each 1,000 feet
above sea level, and will also
decrease about 1% for each
10°F (6°C) above 60°F (16°C)
ambient temperature.


Product specificaties

Merk: Westinghouse
Categorie: Generator
Model: iGen2500

Heb je hulp nodig?

Als je hulp nodig hebt met Westinghouse iGen2500 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Generator Westinghouse

Handleiding Generator

Nieuwste handleidingen voor Generator