Westinghouse iGen2200c Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Westinghouse iGen2200c (80 pagina's) in de categorie Generator. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/80
USER MANUAL
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer
service at 855-944-3571.
iGen c2200
Digital Inverter Generator
1800 Running Watts | 2200 Peak Watts
2 | Westinghouse Outdoor Power Equipment, LLC
WARNING: Operating, servicing, and maintaining
this equipment can expose you to chemicals including
engine exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects or other reproductive harm. To
minimize exposure, avoid breathing exhaust, and wear
gloves or wash your hands frequently when servicing
this equipment. For more information go to www.
P65warnings.ca.gov.
DISCLAIMERS
All information, illustrations, and speciî·”cations in
this manual were in effect at the time of publishing.
The illustrations used in this manual are intended as
representative reference views only. We reserve the right
to make any speciî·”cation or design change without notice.
ALL RIGHTS RESERVED
All rights reserved. No reproduction allowed in any form
without written permission from Westinghouse Outdoor
Power Equipment, LLC.
DANGER
Read this manual before using or performing
maintenance on this product. Failure to follow
the instructions and safety precautions in this
manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
INTRODUCTION
DISCLAIMERS 2 .........................................................................
ALL RIGHTS RESERVED 2 ........................................................
SPECIFICATIONS....................................................................3
SAFETY
SAFETY DEFINITIONS............................................................4
SAFETY SYMBOLS 4 .................................................................
SAFETY INSTRUCTIONS 5 .......................................................
GENERAL SAFETY PRECAUTIONS 6 ......................................
SAFETY LABELS AND DECALS 7 .............................................
CO SENSOR 8 ............................................................................
ACTION LABEL ........................................................................8
CONTROL PANEL CO AUTO-SHUTOFF 8 ................................
COMPONENTS
GENERATOR COMPONENTS 9 ................................................
CONTROL PANEL COMPONENTS 10 .......................................
ASSEMBLY
CARTON CONTENTS ........................................................... 11
INITIAL OIL FILL ....................................................................11
FUEL ...................................................................................... 11
FILLING THE FUEL TANK .....................................................12
OPERATION
GENERATOR LOCATION 13 ......................................................
HIGH ALTITUDE OPERATION ..............................................13
BREAK-IN PERIOD 14 ...............................................................
BEFORE STARTING THE GENERATOR 14 ..............................
STARTING THE ENGINE ......................................................14
FREQUENCY OF USE 14 ..........................................................
ECO MODE 15 ............................................................................
AC CIRCUIT BREAKER.........................................................15
OVERLOAD RESET 15 ..............................................................
POWER MANAGEMENT 16 .......................................................
EXTENSION CORDS 16 ............................................................
PARALLEL OPERATION........................................................17
TRANSPORTING 17 ...................................................................
MAINTENANCE
MAINTENANCE SCHEDULE 18 ................................................
MAINTENANCE REPLACEMENT PARTS 18 ............................
ENGINE SERVICE COVER 18 ...................................................
AIR FILTER MAINTENANCE 18 .................................................
ENGINE OIL LEVEL CHECK 19 .................................................
ENGINE OIL CHANGE 19 ..........................................................
SPARK PLUG MAINTENANCE 20 .............................................
SPARK ARRESTOR SERVICE ..............................................20
STORAGE 21 ..............................................................................
VALVE CLEARANCE 22 .............................................................
TROUBLESHOOTING
TROUBLESHOOTING 23 ...........................................................
EXPLODED VIEW AND PARTS LISTS
EXPLODED VIEW A ..............................................................24
EXPLODED VIEW B 26 ..............................................................
SCHEMATIC
SCHEMATIC 29 ..........................................................................
ESPAÑOL .............................................................................30
FRANÇAIS ...........................................................................55
INTRODUCTION
INTRODUCTION
Westinghouse Outdoor Power Equipment, LLC | 3
INTRODUCTION
SPECIFICATIONS
Speciî·”cations
Running Watts: 1800
Peak Watts: 2200
Rated Power @1.0 Power
Factor: 1.8 kW Gasoline
Peak Power: 2.2 kVA Gasoline
Rated Voltage: 120V
Rated frequency: 60 Hz @ 3600 RPM
Phase: Single phase
Total Harmonic
Distortion: ≤ 3%
Engine Displacement: 79 cc
Starting Type: Recoil
Fuel Capacity: 1.14 Gallons (4.3 Liters)
Fuel Type: Unleaded gasoline
87–93 Octane*
Oil Capacity: .37 qt. (11.8 oz.)
Oil Type: SAE 10W-30
Spark Plug: Torch E6RTC
Spark Plug Gap: 0.024 – 0.032 in.
(0.60 – 0.80 mm)
Valve Intake
Clearance:
0.0031 – 0.0047 in.
(0.08 – 0.12 mm)
Valve Exhaust
Clearance:
0.0051 – 0.0067 in.
(0.13 – 0.17 mm)
AC Grounding System: Floating neutral
Voltage Regulator: AVR
Alternator Type: Permanent magnet
Maximum Ambient
Temperature: 104°F (40°C)
Certiî·”cations:
• EPA
• CARB
• CSA Group
* Ethanol content of 10% or less. DO NOT use E15 or E85.
NOTICE
This product is designed and rated for continuous
operation at ambient temperatures up to 104°F (40°C).
If needed, this product can be operated at temperatures
ranging from 5°F (15°C)–122°F (50°C) for short periods.
If the product is exposed to temperatures outside of this
range during storage, it should be brought back within
this range before operation. This product must always
be operated outdoors in a well-ventilated area and far
away from doors, windows, and other vents.
Maximum wattage and current are subject to and
limited by such factors as fuel BTU content, ambient
temperature, altitude, engine conditions, etc. Maximum
power decreases about 3.5% for each 1,000 feet above
sea level, and will also decrease about 1% for each 10°F
(6°C) above 60°F (16°C) ambient temperature.
PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to
register your Westinghouse generator.
You can register by:
• Completing and mailing the product registration card
included in the carton.
• Registering your product on-line at:
https://westinghouseoutdoorpower.com/pages/
warranty-registration
• Scan the following QR code with your smartphone
camera to be directed to the mobile registration link.
• Sending the following product information to:
Westinghouse Outdoor Power
Warranty registration
777 Manor Park Drive
Columbus, OH 43228
For Your Records
Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:
IMPORTANT: Keep your purchase receipt for trouble-free
warranty coverage.


Product specificaties

Merk: Westinghouse
Categorie: Generator
Model: iGen2200c

Heb je hulp nodig?

Als je hulp nodig hebt met Westinghouse iGen2200c stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Generator Westinghouse

Handleiding Generator

Nieuwste handleidingen voor Generator