Uni-T UT285C Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Uni-T UT285C (78 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 21 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/78
2023/12/05
P/N:110401110254X
Power Quality Analyzer
Warning
Thank you for purchasing UT285C AnalyzerPower Quality . To better use this product, please be sure to:
----Read this user manual thoroughly.
----Comply with the safe regulations and operating cautions strictly in this manual.
Failure to comply with follow precautions may cause electric shock, explosion, or fire.
Under any circumstance, please pay special attention on safe in us this device.ty ing
Pay attention to words and symbols affixed on the panel and back of the device. cover
This device must be used, disassembled and repaired by authorized professionals.
If continuou s use of this device is dangerous to the user, please stop use immediately and seal the device,
and then send it to authorized body for maintenance.
The danger symbol in manual ” indicates that users must perform safe operation in compliance with
the manual instructions.
The extreme danger symbol in manual indicates that users must perform safe operation strictly in
compliance with the manual instructions.
Before removing and replacing the battery or the SD please power off the device and disconnect it -Card,
from tested line, current sensor, power adaptor .
Current clam p must be connected with the device correspondingly, otherwise the test error may be
increased.
Please do not use the device if the battery or SD card slot is missing , dam ag ed or improperly installed.
The founder and operator of the system shall be responsible for any system security problems unrelated to
this Analyzer.
For safety, please use only the wires and accessories supplied with the Analyzer (in accordance with the
standard of IEC61010-031(2002)). When a sensor or accessories -in low voltage class are connected to the
device, which must be applicable to the system of this device.
Please always check test leads, current clamps and accessories are in optimum condition before use. Any
wire, current clamp or accessory even partially damaged) must be repaired or with damaged insulation (or
scrapped.
Comply with the environm ental condition 15.3.1)( refer to
Please use personal safety equipment when necessary.
The Analyzer should be used in devices with AC/DC voltage not greater than CAT IV 600V to ground
(IEC61010-1 standard), or used in devices with voltage not greater than CAT III 1000V. It is forbidden to use
for power grids or measurement category with higher voltage.
Use only the power adapter or battery pack supplied by the manufacturer, which is designed in accordance
with specific safety rating.
Please comply with the safety rating for the accessories or current clamp. Do not make connection with any
unused terminals.
Some current clamps cannot be installed or removed from exposed conductors under the dangerous to
voltage.
Usage & Connection Step:
Start up . the Analyzer
Set the relevant parameters of the according to the Analyzer desired results and the network type.
Connect the voltage test leads and current sensors to the Analyzer.
Connect the ground line and/or neutral line of the voltage test leads ground line and/or neutral to the line of
the p . ower grid
Connect the neutral line of current sensor to the neutral line of power grid.
Connect the L1 phase lead to the L1 phase of power grid and the corresponding current sensor clamp to the
phase L1 of power grid .
Repeat the above connection steps for phases L2, L3.
Note: Complying with this procedure reduces connection errors to minimum and avoids operation wasting
time.
D iscon n ectio n Steps:
Disconnect the wiring in reverse order disconnect the ground line or neutral line at last in general ( ).
Remove all the leads of the and shutAnalyzer it . down
Cha rge the battery and upload the test data when necessary.
USB is used for data transmission. Battery can be charged by the supplied special adapter.
Dotted E O T C C nds f he urrent lamp
The side with current clamp marks (L1, L2, L3, N/D or has red dot is the current noninverting input) end,
which is dotted end.
The side of 008B current clamp has red dot is the current noninverting input end, that is dotted end.
The side of 040B, 068B current clamp without screws is the current noninverting input end, which is dotted
end.
The side with the lock symbol “ of the 300F flex current sensor as the current noninverting input end, i ble
that is dotted end.


Product specificaties