Toshiba RAS-07YA-ES Handleiding

Toshiba Airco RAS-07YA-ES

Lees hieronder de 📖 handleiding in het Nederlandse voor Toshiba RAS-07YA-ES (60 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 59 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/60
SERVICE MANUAL
FILE NO. DAS-SM-00-001
AIR-CONDITIONER
SPLIT WALL TYPE
RAS-07YKX
/
RAS-07YAX
RAS-10YKX
/
RAS-10YAX
RAS-11YKX
/
RAS-11YAX
RAS-07YK-E
/
RAS-07YA-E
RAS-10YK-E
/
RAS-10YA-E
RAS-07YK-ES/RAS-07YA-ES
RAS-10YK-ES
/
RAS-10YA-ES
RAS-10YK-HX
/
RAS-10YA-HX
RAS-07YKX-T
/
RAS-07YAX-T
RAS-10YKX-T
/
RAS-10YAX-T
– 2 –
CONTENTS
1. SPECIFIC TION .....................................................................................A S 3
2. CONST UCTION VIEWSR ........................................................................ 8
3. WIRING DI GRAMA ................................................................................. 10
4. SPECIFIC TIONS OF ELECTRICAL SA PART ...................................... 11
5. REFRIGERANT CYCLE DI GRAMA .................................................... .. 13
6. CONT OL BLOCK DI GRAMR A .............................................................. 14
7. OPER TION DESCRIPTION ................................................................A S . 15
8. INS ALL TION P OCEDURET A R ............................................................... 20
9. TR ROUBLESHO TING CHAO T ............................................................... 33
10. PART REPL CEMEN ...................................................................... ....A T . 46
11. EXPLODED VIEWS AND TS LIST PAR ............................................... 50
– 3 –
1. SPECIFICATIONS
RAS-07YKX/07YAX, RAS-07YK-E/07YA-E, RAS-07YKX-T/07YAX-T
↑
↓
RAS-07YK-E/YA-E RAS-07YKX/YAX RAS-07YKX-T/YAX-T
MODEL
ITEM Cooling
220V–240V 220V
Capacity kW *12,10–2,20 2,10
Phase Single
V 220–240 220Power source
Hz 50
Power consumption kW 0,60–0,65 0,60
Power factor % 96–94 96
V 220V–240V 220V
Running current Indoor/Outdoor A 0,15/2,70–0,15/2,72 0,15/2,70
Starting current A 12
Moisture removal lit/h 0,8
Indoor (H/M/L) dB (A) 39 / 33 / 29
Noise
(SPL at 1 meter) Outdoor (220–240V) dB (A) 44–45 44
Name of refrigerant R-22
Refrigerant Rated volume kg 0,59
Refrigerant control Capillary tube
Gas side size mm 9,52
Connection type Flare connection
Liquid side size mm 6,35
Connection type Flare connection
Maximum length (of one way) m
*2 10
Interconnection pipe
Maximum height difference
Indoor unit
Outdoor unit m5
Condensate drain pipe Outer diameter mm 16
INDOOR UNIT RAS-07YK-E RAS-07YKX RAS-07YKX-T
Height mm 265
Width mm 790Dimensions
Depth mm 189
Net weight kg 8
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m³/h 550
Medium fan m³/h 490Air flow rate
Low fan m³/h 430
Fan motor output W 20
Air filter Polypropylene net filter (Washable)
OUTDOOR UNIT RAS-07YA-E RAS-07YAX RAS-07YAX-T
Height mm 530
Width mm 770Dimensions
Depth mm 200
Net weight kg 26
Condenser type Finned tube
Outdoor fan type Propeller
Air flow rate (220– ³240V) m /h 1500–1700 1500
Fan motor output W 18 (UE6-21SJ5P) 18 (UE6-21A5P), 20 (HF-240-20A)
Model PH80T1-4C
Compressor Output W 605
Safety device Fuse, Overload relay
Auto louver Yes
Usable outdoor temperature range °C 21–43
Specifications are subject to change without notice.


Product specificaties

Merk: Toshiba
Categorie: Airco
Model: RAS-07YA-ES

Heb je hulp nodig?

Als je hulp nodig hebt met Toshiba RAS-07YA-ES stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Toshiba

Handleiding Airco

Nieuwste handleidingen voor Airco