Spring USA SM-300CR Handleiding

Spring USA Fornuis SM-300CR

Lees hieronder de đź“– handleiding in het Nederlandse voor Spring USA SM-300CR (8 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
The Unlimited
Induction Range
Item #: -300CRSM
Owner’s Manual
127 Ambassador Drive, Suite 147
Naperville, IL 60540-4079
P: 630- -527 8600
F: 630- -527 8677
springusa@springusa.com
www.springusa.com
The Evolution of Intelligent Design®
Aug 2020
The Evolution of Intelligent Design®
Electr
Electr
Electr
ElectrElectric
ic
ic
icical
al
al
alal
R
R
R
RReq
eq
eq
eqequir
uir
uir
uiruire
e
e
eem
m
m
mme
e
e
een
n
n
nnts:
ts:
ts:
ts:ts:
32
Bef
Bef
Bef
BefBefor
or
or
orore
e
e
e e Y
Y
Y
YYou
ou
ou
ou ou Begin
Begin
Begin
BeginBegin
To ensure safe operation, read the following instructions in their
entirety.
Warning is used to indicate the presence of a hazard that can cause
severe personal injury, death, or substantial property damage if the
warning is ignored.
Caution is used to indicate the presence of a hazard that will or can
cause minor personal injury or property damage if the caution is
ignored.
NOTICE
Notice is used to note information that is important but not
hazard-related.
T
T
T
TTo
o
o
o o reduc
reduc
reduc
reducreduce
e
e
e e risk
risk
risk
risk risk o
o
o
oof
f
f
f f injury
injury
injury
injury injury or dam
or dam
or dam
or damor damage
age
age
age age to the
to the
to the
to the to the equipm
equipm
equipm
equipmequipment:
ent:
ent:
ent:ent:
•Plug only into grounded electrical outlets matching the nameplate
rated voltage.
•Do not power the equipment with extension cords, power strips, or
multipurpose sockets.
•Equipment should only be used in a flat, level position.
•Do not obstruct or cover the equipment in any way when in use.
•Do not operate unattended.
•Do not leave an empty vessel on the equipment when in use.
•Closely supervise equipment operating in public areas and/or around
children.
•Do not operate if equipment has been damaged or is malfunctioning
in any way.
•Keep equipment and power cord away from open flames, electric
burners or excessive heat.
•Unplug equipment and let it cool before cleaning.
•Unplug when not in use.
ENGL
ENGL
ENGL
ENGLENGLISH
ISH
ISH
ISHISH Funct
Funct
Funct
FunctFunction
ion
ion
ionion
Spring USA’s Unlimited Induction Range, item #SM-300CR, is a portable,
product holding range intended for countertop use. The range features
a durable, all-black housing with touch controls. The range has been
designed specifically to keep food warm. Food must be at or above
serving temperature before being placed on the range.
Item # Voltage Phase Hertz Watts Amps Plug
SM-300CR - 1 2.5 NEMA 5-110 120 60 300 15P
Inst
Inst
Inst
InstInstalla
alla
alla
allaallatio
tio
tio
tiotion
n
n
nn
Inspect all parts of the induction range prior to installation and use. If
the unit is damaged, do not use. Contact a supplier for a replacement.
Ensure the installation location has dedicated power. The Unlimited
Induction Range can be used as a countertop unit or built-in unit.
To prepare the induction range for countertop use, simply place the
unit on a flat, level surface. There must be at least 1.2” (3 cm) of space
available around the induction range for proper ventilation on the
countertop.
NOTICE: The induction range only maintains temperature it –
does not cook or continue to cook food.
Dais
Dais
Dais
DaisDaisy
y
y
y y Chaini
Chaini
Chaini
ChainiChaining
ng
ng
ngng:
:
:
::
The Unlimited Induction Range has a built-in receptacle located in the
back of the unit that allows for daisy chaining. The maximum number of
Unlimited Range units allowed for daisy chaining into one 15-amp/120-
volt circuit is 5
5
5
55 units.
units.
units.
units.units.
To install the induction range as a built-in unit follow the below steps:
1. Ensure the installation location has proper ventilation. There must
be at least 7” of available space under the mounted induction range
and the inside temperature of the cabinet must not exceed
90°F/32°C.
4 5
NOTICE: Countertop thickness must not exceed 2.0”.
Figure
Figure
Figure
Figure Figure 1. Control
1. Control
1. Control
1. Control 1. Control Panel
Panel
Panel
Panel Panel Re
Re
Re
ReRemo
mo
mo
momoval
val
val
valval
2. Remove the control panel from
the body of the induction range.
Simply pull the panel straight out
by the bottom corners of the
panel. See Figure 1 for reference.
The control panel will be
mounted separately for easy
access.
3. Position the provided template in the intended installation location,
allowing a minimum of 4” of countertop space on each side of the
induction range. Cut the countertop using the template.
4. Insert the induction range into the cutout. The induction range will
sit 0.4” (10 mm) above the surface of the countertop. Apply a thin
bead rubber silicone sealant around the surface perimeter of 100%
of the mounted induction range.
5. To mount the control panel, position the provided template aon
plane or panel perpendicular to the induction range. Center the
control panel to the induction range whenever possible. Cut the
intended surface using the template.
6. Insert the control panel into the cutout and secure with (4)
mounting screws.
7. Connect the control panel cable the induction range.to
Oper
Oper
Oper
OperOpera
a
a
aati
ti
ti
tition
on
on
onon
To operate the induction range, induction-ready vessels must be used.
•Glass serving vessels are not suited for use on the induction range.
•Vessels must have a flat base in order to make full contact with the
range. Vessels that are footed, or that have a raised ridge, are not
suited for the induction range.
•Vessels must have a base diameter greater than 4.7”.
Follow the below steps for operating the induction range:
1. Plug in the unit. Press the ON/OFF button.
2. Place the vessel on the induction range surface.
3. The LED lights above each setting will blink until a setting is pressed
4. Press the desired setting button. See the below chart for
temperature ranges.
NOTICE:
Spring USA induction servers and induction ranges are
designed to work together as a system. Optimal
performance is achieved by using Spring USA
components in conjunction with each other. Spring USA
cannot guarantee the performance of facsimile products
offered by other companies.
NOTICE:
As a safety feature, if no induction ready vessel is placed
on the surface after 2.5 minutes, the unit will shut off.
Low Low-Med Med-High High
145-155°F 156-165°F 166-175°F 176-185°F
62-68°C 69-73°C 74-79°C 80-85°C