Smeg TRU36GGWH9 Handleiding

Smeg Fornuis TRU36GGWH9

Lees hieronder de 📖 handleiding in het Nederlandse voor Smeg TRU36GGWH9 (10 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 35 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
Important Safety Instructions
3
EN
IMPORTANT SAFETY INSTRUCTIONS
WARNING: If the instructions contained in this manual are not followed
precisely, fire or explosion may result causing property damage, personal
injury or loss of life.
• Do not store or use gasoline or other flammable vapors or liquids near
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switches.
• Do not use any telephones in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer,
service company or gas supplier.
READ AND SAVE THESE INSTRUCTIONS - Your safety and the safety of
others are very important.
We have provided many important safety messages throughout this manual and
on the appliance.
Read all the instructions before using the appliance and always obey all safety
messages.
RECOGNIZE SAFETY INFORMATION
This is a safety alert symbol. This symbol alerts you to potential hazards that can
result in severe personal injury or loss of life.
UNDERSTAND SIGNAL WORDS
A signal word - DANGER, WARNING or CAUTION - is used with the safety alert
symbol. DANGER denotes the most serious hazards. It means you could lose your
life or be seriously injured if you do not immediately follow the instructions.
WARNING means you could lose your life or be seriously injured if the instructions
are not followed. CAUTION indicates a potentially hazardous situation which, if
not avoided, could result in minor to moderate injury.
Important Safety Instructions
4
The safety messages will inform you of potential hazards, on how to avoid the risk of
injury and what can occur if the instructions are not followed.
IMPORTANT: Observe all codes and ordinances in force.
WARNING: For your safety, the instructions contained in this manual must be
followed to minimize the risk of fire or explosion and to prevent property damage,
personal injury or loss of life.
This conversion kit must be installed by a qualified service agency in accordance
with the manufacturer's instructions and all applicable codes and requirements of
the authority having jurisdiction.
If the information in these instructions is not followed exactly, a fire, an explosion
or production of carbon monoxide may result causing property damage,
personal injury or loss of life.
The qualified service agency is responsible for the proper installation of this kit.
The Installation is not correct and complete until the operation of the converted
appliance is checked as specified in the manufacturer’s instructions supplied with
the kit.
• For an installation at altitudes above 2000 ft (610 mt) contact the Service Centre.
Installation shall not be considered correct and complete until the operation of the
converted appliance is checked as specified in the manufacturer's instructions
supplied with this kit.
WARNING FIRE HAZARD
Securely tighten all gas connections. lf connected to LP, have a
qualified technician ensure that the gas pressure does not
exceed a 14” W.C.P. Examples of qualified technicians include
licensed heating personnel, authorized gas company personnel
and authorized service personnel.
FAILURE TO DO SO CAN RESULT IN LOSS OF LIFE,
EXPLOSION, OR FIRE.
Caution: Before proceeding with the conversion, the gas supply must be shut off
prior to disconnecting the electrical power.
Conversion Kit
5
EN
1 List of components
This conversion kit consists of the following
components:
• One label for LPG injectors
• One injector Ø 0.60 mm for
the burners.Auxiliary
• Two injectors Ø 0.80 mm for
the burners.Semi-rapid
• One injector Ø 0.98 mm for
the burner.Rapid
• One injector Ø 0.54 Ultra- mm for the
rapid Dual internal crown burner ( ).
• One injector Ø 1.10 Ultra- mm for the
rapid Dual external crown burner ( ).
• Two injectors Ø 1.20 mm for Oven and
Broiler burners.
• One warning label change injectors
• Two seal gaskets
12.5x18.5x2 (mm).


Product specificaties

Merk: Smeg
Categorie: Fornuis
Model: TRU36GGWH9

Heb je hulp nodig?

Als je hulp nodig hebt met Smeg TRU36GGWH9 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis Smeg

Smeg

Smeg C9GMX9 Handleiding

19 December 2024
Smeg

Smeg SIM1844DS Handleiding

14 December 2024
Smeg

Smeg SIM1844D Handleiding

14 December 2024
Smeg

Smeg C6GMXNLK2 Handleiding

7 December 2024
Smeg

Smeg C6GMXD2 Handleiding

7 December 2024
Smeg

Smeg C6IMMBT2 Handleiding

7 December 2024
Smeg

Smeg SAI4744D Handleiding

25 November 2024
Smeg

Smeg SAI4634D Handleiding

25 November 2024
Smeg

Smeg SAIG6954R Handleiding

25 November 2024
Smeg

Smeg SIM1644DS Handleiding

21 November 2024

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis