Siemens LR96CAQ50B Handleiding

Siemens Afzuigkap LR96CAQ50B

Lees hieronder de 📖 handleiding in het Nederlandse voor Siemens LR96CAQ50B (28 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/28
Ceiling-mounted ventilation system
LR96CAQ20, LR96CAQ50, LR96CAQ50B
en User manual and installation instructions
Register your product on My Siemens and discover exclusive ser-
vices and offers.
siemens-home.bsh-group.com/welcome
The future moving in.
Siemens Home Appliances
en Safety
2
Table of contents
INFORMATION FOR USE
1 Safety....................................................................2
2 Preventing material damage ...............................5
3 Environmental protection and saving en-
ergy .......................................................................5
4 Operating modes .................................................5
5 Familiarising yourself with your appliance ........7
6 Before using for the first time .............................7
7 Basic operation ....................................................7
8 HomeConnect .....................................................9
9 Hob-based hood control....................................10
10 Cleaning and servicing......................................11
11 Troubleshooting.................................................13
12 Customer Service...............................................14
13 Accessories........................................................14
14 Disposal..............................................................15
15 Declaration of Conformity .................................15
16 INSTALLATION INSTRUCTIONS .......................15
16.4 Secure installation .............................................17
1 Safety
Observe the following safety instructions.
1.1 General information
¡Read this instruction manual carefully.
¡Keep the instruction manual and the
product information safe for future refer-
ence or for the next owner.
¡Do not connect the appliance if it has been
damaged in transit.
1.2 Intended use
This appliance is designed only to be built
into kitchen units. Read the special installation
instructions.
The appliance can only be used safely if it is
correctly installed according to the safety in-
structions. The installer is responsible for en-
suring that the appliance works perfectly at its
installation location.
Only use this appliance:
¡For extracting cooking vapour.
¡In private households and in enclosed
spaces in a domestic environment.
¡Up to an altitude of max. 2000m above
sea level.
Do not use the appliance:
¡With an external timer.
1.3 Restriction on user group
This appliance may be used by children aged
8 or over and by people who have reduced
physical, sensory or mental abilities or inad-
equate experience and/or knowledge,
provided that they are supervised or have
been instructed on how to use the appliance
safely and have understood the resulting
dangers.
Do not let children play with the appliance.
Children must not perform cleaning or user
maintenance unless they are at least 15 years
old and are being supervised.
Keep children under the age of 8 years away
from the appliance and power cable.
1.4 Safe use
WARNING‒Risk of suffocation!
Children may put packaging material over
their heads or wrap themselves up in it and
suffocate.
â–¶Keep packaging material away from chil-
dren.
â–¶Do not let children play with packaging ma-
terial.
Children may breathe in or swallow small
parts, causing them to suffocate.
â–¶Keep small parts away from children.
â–¶Do not let children play with small parts.
Safety en
3
WARNING‒Risk of poisoning!
Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-pro-
ducing appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and dis-
charge the exhaust gases into the open
through an exhaust gas system (e.g. a chim-
ney). With the extractor hood switched on, air
is extracted from the kitchen and the adjacent
rooms. Without an adequate supply of air, the
air pressure falls below atmospheric pressure.
Toxic gases from the flue or the extraction
shaft are sucked back into the living space.
â–¶Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as a
room-air-dependent heat-producing appli-
ance is being operated.
â–¶It is only possible to safely operate the ap-
pliance if the pressure in the room in which
the heating appliance is installed does not
drop more than 4Pa(0.04mbar) below at-
mospheric pressure. This can be achieved
whenever the air needed for combustion is
able to enter through openings that cannot
be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by
other technical means. An incoming/ex-
haust air wall box alone does not ensure
compliance with the limit.
â–¶In any case, consult your responsible chim-
ney sweep. They are able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures
to you.
â–¶Unrestricted operation is possible if the ap-
pliance is operated exclusively in circulat-
ing-air mode.
WARNING‒Risk of fire!
Fatty deposits in the grease filters may catch
fire.
â–¶Never operate the appliance without a
grease filter.
â–¶Clean the grease filters regularly.
â–¶Never work with naked flames close to the
appliance (e.g. flambéing).
â–¶Do not install the appliance near a solid
fuel heating appliance (e.g. wood- or coal-
burning) unless the heating appliance has
a sealed, non-removable cover. There must
be no flying sparks.
Hot oil or grease ignites very quickly.
â–¶Always supervise hot oil and fat.
â–¶Never extinguish burning oil or fat with wa-
ter. Switch off the cooking zone. Extinguish
flames carefully using a lid, fire blanket or
something similar.
When gas burners are in operation without
any cookware placed on them, they can build
up a lot of heat. A ventilation appliance in-
stalled above the cooker may become dam-
aged or catch fire.
â–¶Only operate the gas burners with cook-
ware on them.
Operating multiple gas hobs at the same time
generates a great deal of heat. A ventilation
appliance installed above the cooker may be-
come damaged or catch fire.
â–¶Only operate the gas hobs with cookware
on them.
â–¶Select the highest fan setting.
â–¶Never operate two gas hobs simultan-
eously on the highest flame for longer than
15 minutes. Two gas hobs correspond to
one large burner.
â–¶Never operate large burners of more than
5kW with the highest flame for longer
than 15minutes, e.g. a wok.
WARNING‒Risk of burns!
The accessible parts of the appliance become
hot during operation.
â–¶Never touch these hot parts.
â–¶Keep children at a safe distance.
The appliance becomes hot during operation.
â–¶Allow the appliance to cool down before
cleaning.


Product specificaties

Merk: Siemens
Categorie: Afzuigkap
Model: LR96CAQ50B
Soort bediening: Draadloos
Kleur van het product: Roestvrijstaal
Gewicht: 20300 g
Breedte: 900 mm
Diepte: 500 mm
Snoerlengte: 1.3 m
Geluidsniveau: 61 dB
Energie-efficiëntieklasse: B
Jaarlijks energieverbruik: 35.1 kWu
Soort: Plafond inbouw
Motor vermogen: 190 W
Uitlaat aansluiting diameter: 150 mm
Motor inbegrepen: Ja
Maximale afzuigcapaciteit: 434 m³/uur
Afzuigmethode: Afvoerend/recirculerend
Fluid dynamic efficiency class: A
Verlichtingefficiëntieklasse: A
Vetfilterefficiëntieklasse: E
Geluidsniveau (lage snelheid): 47 dB
Minimale afstand van electrische hob: 650 mm
Minimale afstand van gas hob: 650 mm
Aantal lampen: 4 gloeilamp(en)
Type lamp: LED
Soort vetfilter: Roestvrijstaal
Wasbaar filter: Ja
Hoogte (min): 189 mm
Hoogte (max): 189 mm
Vermogen lamp: 3 W
Geluidsniveau (hoge snelheid: 61 dB
Maximum hercirculeringsvermogen: 336 m³/uur
Aantal filters: 2 stuk(s)
Installatie compartiment breedte: 888 mm
Installatie compartiment diepte: 487 mm
Aantal snelheden: 3
Geluidsniveau (hercirculatie modus): 61 dB
Verlichtingspositie: Zijkant
Automatisch uitschakelen: Ja
Intensieve stand: Ja
Geluidsniveau (intensieve snelheid): 72 dB
Dimbare verlichting: Ja
Hob²Hood-functie: Ja
Uitlaat locatie: Boven
Vaatwasserbestendig filter: Ja
Druk (Pa): 248
Terugslagklep: Ja
Stroomverbruik (in standby): 0.3 W
Kleurtemperatuur: 5000 K
Afstandsbediening inbegrepen: Ja
AC-ingangsspanning: 220-240 V
AC-ingangsfrequentie: 50/60 Hz
Energie-efficiëntieschaal: A+++ tot D
Type motor: BLDC
Indicator filterreiniging: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met Siemens LR96CAQ50B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Siemens

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap

Pando

Pando E-265 Handleiding

18 December 2024
Pando

Pando GR-05 Handleiding

18 December 2024
Pando

Pando I-826 Handleiding

18 December 2024
Franke

Franke 1221A-10 Handleiding

16 December 2024
Franke

Franke 1209B-60 Handleiding

16 December 2024
Franke

Franke 1222A-10 Handleiding

16 December 2024
Franke

Franke 1261A Handleiding

16 December 2024
Franke

Franke 1221B-10 Handleiding

16 December 2024
Franke

Franke 1221B-12 Handleiding

16 December 2024