Siemens LI97RA560 Handleiding

Siemens Afzuigkap LI97RA560

Lees hieronder de 📖 handleiding in het Nederlandse voor Siemens LI97RA560 (20 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 51 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/20
5HJLVWHU
\RXU
SURGXFW
RQOLQH
VLHPHQVKRPHEVKJURXSFRPZHOFRPH
[en]Instructions for installation and use
Extractor hood
en
2
Table of contents
[ en] I nst r u ct i o ns f or i n s t al l at i on a nd us e
INSTRUCTION MANUAL.......................................................... 2
8Intended use..........................................................2
(Important safety information ...............................3
7Environmental protection.....................................5
ÇOperating modes...................................................5
1Operating the appliance .......................................6
2Cleaning and maintenance...................................8
3Trouble shooting...................................................9
4Customer service................................................10
INSTALLATION INSTRUCTIONS........................................... 11
(Important safety information .............................12
KGeneral information............................................13
5Installation ...........................................................16
INSTRUCTION MANUAL
Produktinfo
Additional information on products, accessories,
replacement parts and services can be found at
www.siemens-home.bsh-group.com and in the online
shop www.siemens-home.bsh-group.com/eshops
8Intended use
I nt e nded us e
Read these instructions carefully. Only then
will you be able to operate your appliance
safely and correctly. Retain the instruction
manual and installation instructions for future
use or for subsequent owners.
The appliance can only be used safely if it is
correctly installed according to the safety
instructions. The installer is responsible for
ensuring that the appliance works perfectly at
its installation location.
This appliance is intended for domestic use
and the household environment only. The
appliance is not intended for use outside. Do
not leave the appliance unattended during
operation. The manufacturer is not liable for
damage which is caused by improper use or
incorrect operation.
This appliance is intended for use up to a
maximum height of 2000 metres above sea
level.
This appliance may be used by children over
the age of 8 years old and by persons with
reduced physical, sensory or mental
capabilities or by persons with a lack of
experience or knowledge if they are
supervised or are instructed by a person
responsible for their safety how to use the
appliance safely and have understood the
associated hazards.
Children must not play with, on, or around the
appliance. Children must not clean the
appliance or carry out general maintenance
unless they are at least 15 years old and are
being supervised.
Keep children below the age of 8 years old at
a safe distance from the appliance and power
cable.
Check the appliance for damage after
unpacking it. Do not connect the appliance if it
has been damaged in transport.
This appliance is not intended for operation
with an external clock timer or a remote
control.
Important safety information en
3
(Important safety
information
I mpo r t an t s af e t y i nf o r mat i o n
:Warning – Danger of suffocation!
Packaging material is dangerous to children.
Never allow children to play with packaging
material.
:Warning – Danger of death!
Risk of poisoning from flue gases that are
drawn back in.
Always ensure adequate fresh air in the room
if the appliance is being operated in exhaust
air mode at the same time as room air-
dependent heat-producing appliance is being
operated.
Room air-dependent heat-producing
appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and discharge
the exhaust gases into the open air through an
exhaust gas system (e.g. a chimney).
In combination with an activated vapour
extractor hood, room air is extracted from the
kitchen and neighbouring rooms - a partial
vacuum is produced if not enough fresh air is
supplied. Toxic gases from the chimney or the
extraction shaft are sucked back into the living
space.
Adequate incoming air must therefore
always be ensured.
An incoming/exhaust air wall box alone will
not ensure compliance with the limit.
Safe operation is possible only when the
partial vacuum in the place where the heat-
producing appliance is installed does not
exceed 4 Pa (0.04 mbar). This can be
achieved when the air needed for combustion
is able to enter through openings that cannot
be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by other
technical means.
In any case, consult your responsible Master
Chimney Sweep. He is able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures to
you.
Unrestricted operation is possible if the vapour
extractor hood is operated exclusively in the
circulating-air mode.
:Warning – Risk of fire!
Grease deposits in the grease filter may
catch fire.
Clean the grease filter at least every
2 months.
Never operate the appliance without the
grease filter.
Risk of fire!
Grease deposits in the grease filter may
catch fire. Never work with naked flames
close to the appliance (e.g. flambéing). Do
not install the appliance near a heat-
producing appliance for solid fuel (e.g.
wood or coal) unless a closed, non-
removable cover is available. There must
be no flying sparks.
Risk of fire!
Hot oil and fat can ignite very quickly. Never
leave hot fat or oil unattended. Never use
water to put out burning oil or fat. Switch off
the hotplate. Extinguish flames carefully
using a lid, fire blanket or something similar.
Risk of fire!
When gas burners are in operation without
any cookware placed on them, they can
build up a lot of heat. A ventilation
appliance installed above the cooker may
become damaged or catch fire. Only
operate the gas burners with cookware on
them.
Risk of fire!
Operating several gas burners at the same
time gives rise to a great deal of heat. A
ventilation appliance installed above the
cooker may become damaged or catch fire.
Never operate two gas burners
simultaneously on the highest flame for
longer than 15 minutes. One large burner of
more than 5 kW (wok) is equivalent to the
power of two gas burners.


Product specificaties

Merk: Siemens
Categorie: Afzuigkap
Model: LI97RA560
Soort bediening: Knoppen
Kleur van het product: Roestvrijstaal
Ingebouwd display: Ja
Breedte: 898 mm
Diepte: 290 mm
Hoogte: 426 mm
Netbelasting: 146 W
Snoerlengte: 1.75 m
Geluidsniveau: 54 dB
Energie-efficiëntieklasse: A
Jaarlijks energieverbruik: 35 kWu
Soort: Inbouw
Illuminance: 569 Lux
Aantal motors: 2
Maximale afzuigcapaciteit: 700 m³/uur
Afzuigmethode: Afvoerend/recirculerend
Fluid dynamic efficiency class: A
Verlichtingefficiëntieklasse: A
Vetfilterefficiëntieklasse: B
Geluidsniveau (lage snelheid): 42 dB
Aantal lampen: 2 gloeilamp(en)
Type lamp: LED
Soort vetfilter: Roestvrijstaal
Wasbaar filter: Ja
Vermogen lamp: 3 W
Maximum hercirculeringsvermogen: 290 m³/uur
Installatie compartiment breedte: 524 mm
Installatie compartiment diepte: 290 mm
Installatie compartiment hoogte: 385 mm
Aantal snelheden: 3
Intensieve stand: Ja
Vaatwasserbestendig filter: Ja
Geluidsniveau (boost-modus): 66 dB
AC-ingangsspanning: 220-240 V
AC-ingangsfrequentie: 50 - 60 Hz

Heb je hulp nodig?

Als je hulp nodig hebt met Siemens LI97RA560 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Siemens

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap

Pando

Pando E-265 Handleiding

18 December 2024
Pando

Pando GR-05 Handleiding

18 December 2024
Pando

Pando I-826 Handleiding

18 December 2024
Franke

Franke 1221A-10 Handleiding

16 December 2024
Franke

Franke 1209B-60 Handleiding

16 December 2024
Franke

Franke 1222A-10 Handleiding

16 December 2024
Franke

Franke 1261A Handleiding

16 December 2024
Franke

Franke 1221B-10 Handleiding

16 December 2024
Franke

Franke 1221B-12 Handleiding

16 December 2024