LCD Display / Custom Settings Sekonic L-608
To set Custom Settings (DIP Switch 4): Located in Battery Compartment.
1. Turn power off.
2. Open battery compartment door and set DIP Switch 4 (CS) to ON
(up position).
3. Turn power on. βCSβ (Custom Settings) will appear in upper right
hand corner.
4. Use JOG WHEEL to select Custom Setting number (No.)-see chart below.
5. Press Mode Key to Select Item Number (Item #)-see chart below.
6. Set DIP switch 4 (CS) to OFF (this will turn power off automatically).
7. Replace battery compartment door and press power button on.
NOTE: Pressing M.CLEAR in CS mode will reset all settings to default (No. 0)
0 1 2 3
1Ambient
& Flash ISO 2 Setting Film Sensitivity
1/3 Step
Filter Setting 0.1
EV Step (β5.0EV) - -
2Ambient
& Flash Exposure Compensation Display Setting Always Display Not Displayed - -
3Ambient
& Flash Increments of Shutter Speed 1 Step 1/3 Step 1/2 Step -
4Ambient
& Flash Increments of Aperture 1 Step 1/3 Step 1/2 Step -
5 Ambient T Priority Mode Available Not Available - -
6 Ambient F Priority Mode Available Not Available - -
7 Flash Corded Flash Mode Available Not Available - -
8 Flash Auto-Reset Cordless Flash Mode Available Not Available - -
9 Flash Analyzing Measurement Available Not Available - -
*10 Ambient Luminance Display Not Available Compund +
Individual Compound Individual
11 Ambient Luminance Measurement in Incident Mode Not Available LUX FC LUX, FC
* Individual indicates that LUX and Footcandles (FC) will be displayed w/out f/s (or shutter speed) and Analog Scale.
Compound indicates that LUX and Footcandles will be displayed with f/s (or shutter speed) and Analog Scale.
Custom Setting List
Item
Custom Setting NameLightingNo.
Measuring
Modes Incident / Reflected
Spot Function Icons
ISO Display
Analyzed %
of Flash
Indicator
Luminance
Indicator
Exposure
Compensation
Memory/Multi
Flash Indicator
Battery
Indicator
Shutter
Priority
Indicator,
Shutter
Speed &
f.p.s Display
Analog Scale Digital Aperture Value, Aperture Priority, EV
Brightness Difference, Average Function, EV Display
Radio Trigger Mode
Advanced Functions - Sekonic L-608
Motion Picture (CINE)
Turn JOG WHEEL (in T Priority Mode) past shutter speed
8000 to select f/s (frames per second). Press measure
button.
Averaging Function
After two of more measurements are memorized, toggle
AVE/ key. Averaged exposure will be displayed in digital
and analog readouts. Operates in all measuring modes.
Brightness Difference Function
Can be used in all modes (incident, reflected, ambient and
flash). Take measurement(s), press the AVE/ button
will display. Press and hold down the Measure button. The
difference between the last memorized reading or averaged
reading and new area measured is displayed in +/- 1/10th
steps of EV.
Flash Analyzing
In all flash modes: Take a flash measurement. A combined
reading of both ambient and flash will be displayed. Turn the
JOG WHEEL to adjust ratio between ambient and flash.
Adjust aperature and shutter as required on camera.
EV Readout (DIP Switch 1) Located in the battery
compartment
Set DIP Switch 1 (EV) to βONβ. Select Ambient Mode. Hold
down Mode key and turn JOG WHEEL until EV readout
shows. Press measure button.
Multi Flash Mode (DIP Switch 2)
Set DIP Switch 2 (MULTI) to βONβ. Hold down Mode key and
turn JOG WHEEL to select Cord, Cordless or Radio Trigger
Mode with MLT shown on display. Press Measure button
until target f/stop is achieved.
Buzzer (DIP Switch 3)
Set DIP Switch 3 (BUZZER) to βONβ. Hold down Mode key
and turn JOG WHEEL to select Cordless Flash Mode.
Press Measure button. Trigger flash-buzzer in meter will
sound each time a reading is made.
Exposure Compensation
Hold in both ISO 1 and ISO 2 simultaneously and turn the
JOG WHEEL to exposure compensation needed between
+/- 9.9 EV.
Calibration
Meter must turned off. Tap Power button once while
holding in ISO 1 and ISO 2 keys. CAL will be displayed on
panel. Turn the JOG WHEEL while holding down both ISO
keys to compensate between +/- 1.0 EV.
Quick Guide to the Sekonic L-608
RETRACTABLE
LUMISPHERE
RING
1Β° - 4Β° ZOOM
SPOT RING
SPOT/INCIDENT
SELECTOR SWITCH
MEMORY
BOOSTER
OUTLET
ON/OFF
ISO 1 / ISO 2
MODE KEY
Press while turning JOG WHEEL for:
JOG WHEEL
FLASH CORD
SOCKET
MEMORY CLEAR
BUTTON1/4β TRIPOD
SOCKET
AVERAGE /
BRIGHTNESS
DIFFERENCE
DIOPTER
CORRECTION
RING
MEASUREMENT
BUTTON
LOCK LEVER
AUTO RESET CORDLESS FLASH MODE
DAYLIGHT / AMBIENT MODE
FLASH W/CORD
FLASH RADIO TRIGGERING MODE
Basic Operation - Sekonic L-608
On/Off
Press down power key to turn on meter. Battery icon will
appear Monitors Battery level. Press and hold Power key
to turn off.
Set ISO 1 or ISO 2
Hold down ISO 1 or ISO 2 while turning the JOG WHEEL.
Zoom Spot meter mode
Turn SPOT/INCIDENT SELECTOR SWITCH to to select
Spot. Turn 1Β°-4Β° ZOOM SPOT RING to select measuring
angle. Press measure button.
Incident meter mode
Turn SPOT/INCIDENT SELECTOR SWITCH to to select
Incident. Turn Lumisphere retracting ring counter-clockwise
to the full UP right position. Press measure button.
Measure Brightness / Contrast Difference
Turn Lumisphere retracting ring clockwise to lower the
Lumisphere to the DOWN position. Select measuring mode
then press measure button.
Ambient Reading
Select Ambient Mode by holding down the Mode key and
turning the JOG WHEEL. Press the measure button.
Cord Flash Reading
Select Cord Flash Mode. Connect flash cord. Press
measure button,to trigger flash and measure light.
Cordless Flash Reading
Select Cordless Flash mode. Press measure button, trigger
flash manually, meter measures light, automatically resets.
Radio Triggering Mode (with optional RT-32 Module)
Turn power OFF. Remove Connector cover inside battery
compartment. Insert optional RT-32 Module. Turn Power
ON. Hold MODE key in while turning the JOG WHEEL to
RADIO FLASH TRIGGERING MODE, a blinking channel
number will appear. Turn JOG WHEEL to select channel
number (press mode key to select channel and/or Quad
Triggering zones a, b, c, or d available in channels 17-32).
Hold MODE key in while turning JOG WHEEL clockwise to
return to RADIO FLASH TRIGGERING MODE with f/stop
and shutter speed. Press measure button: simultaneously
fires flash and measures light.
Memory Function
Take measurement, press Memory button. Up to nine
readings can be stored and displayed on the analog memory
scale by repeating the procedure. A tenth measurement can
also be displayed.
- - - - - - ->
- - - - - - -
Product specificaties
Merk: | Sekonic |
Categorie: | Lichtmeter |
Model: | L-608 |
Heb je hulp nodig?
Als je hulp nodig hebt met Sekonic L-608 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Lichtmeter Sekonic
20 Maart 2023
20 Maart 2023
20 Maart 2023
6 Juni 2023
20 Maart 2023
20 Maart 2023
8 Mei 2023
6 Mei 2023
5 Mei 2023
20 Maart 2023
Handleiding Lichtmeter
- Lichtmeter Amprobe
- Lichtmeter Extech
- Lichtmeter Fluke
- Lichtmeter Gossen
- Lichtmeter KlikaanKlikuit
- Lichtmeter Pyle
- Lichtmeter Quantum
- Lichtmeter Uni-T
- Lichtmeter Velleman
- Lichtmeter Voltcraft
- Lichtmeter Steren
- Lichtmeter Klein Tools
- Lichtmeter Testo
- Lichtmeter Testboy
- Lichtmeter Kyoritsu
- Lichtmeter Delta Ohm
Nieuwste handleidingen voor Lichtmeter
8 April 2024
6 Maart 2024
6 Maart 2024
6 Maart 2024
5 Januari 2024
4 Januari 2024
27 November 2023
14 November 2023
15 Augustus 2023
15 Augustus 2023